High-Throughput Ultra Performance Liquid Chromatography-Tandem Mass Spectrometry Method Validation for the Estimation of Atorvastatin and Active Metabolites in Human Plasma

被引:0
|
作者
Agrawal, Nikhil [1 ]
Mittal, Amit [1 ,2 ,3 ]
机构
[1] Lovely Profess Univ, Sch Pharmaceut Sci, Dept Pharmaceut Chem, Phagwara, India
[2] Desh Bhagat Univ, Fac Pharmaceut Sci, Dept Pharmaceut Chem, Mandi Gobindgarh, India
[3] Lovely Profess Univ, Sch Pharmaceut Sci, Dept Pharmaceut Chem, Jalandhar Delhi GT Rd NH 44, Phagwara 144411, Punjab, India
关键词
atorvastatin; active metabolites; ultra high-performance liquid chromatography-liquid chromatography; mass spectrometry; bioanalytical; method validation (UPLC-MS; MS); PARA-HYDROXY ATORVASTATIN; LC-MS/MS; SIMULTANEOUS QUANTIFICATION; MS; QUANTITATION;
D O I
10.1089/adt.2022.113
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A highly selective, sensitive, rugged, and rapid ultra high-performance liquid chromatography-tandem mass spectrometry method (UPLC-MS/MS) is optimized and validated for reliable quantification of atorvastatin (ATR) and its active metabolites, 2-hydroxy atorvastatin (2-ATR) and 4-hydroxy atorvastatin (4-ATR) in human plasma using atorvastatin-D5 (ATR-D5), 2-hydroxy atorvastatin-D5 (2-ATR-D5), and 4-hydroxy atorvastatin-D5 (4-ATR-D5) as deuterium-labeled internal standards (ISTDs), respectively. Isocratic mode chromatographic separation was used with a reverse-phase C-18 Symmetry Shield (150 x 4.6 mm, 5.0 mu m) column and a mobile phase of acetonitrile:2 mM ammonium formate (pH-3.0) [65:35%v/v] at a flow rate of 0.7 mL/min. Electrospray ionization technique with positive ion mode polarity was applied to achieve the best signal intensity and stable response. Solid-phase extraction by direct elution method was applied to extract the drugs from the plasma sample. The calibration curve range was validated from a concentration range of 0.500-250 ng/mL for ATR and 2-ATR and 0.200-20 ng/mL for 4-ATR. The within-batch and between-batch precision and accuracy were found to be consistent and reproducible for all the analytes across the validation. Extraction recoveries were >80% for all analytes and ISTDs. All peaks of analytes and the respective ISTDs were eluted within 5.2 min. In this validated method, selective multivariate analytical approaches were utilized such as best fit linearity range for different strength formulations, preventive measures for in vivo and ex vivo autodegradation of metabolites, and shorter analysis time. This validated method can be useful for challenging quantification of ATR and its active metabolites for therapeutic drug monitoring and in high-throughput clinical study sample analysis.
引用
收藏
页码:110 / 125
页数:16
相关论文
共 50 条
  • [31] Biomonitoring method for bisphenol A in human urine by ultra-high-performance liquid chromatography-tandem mass spectrometry
    Anderson, David J.
    Brozek, Eric M.
    Cox, Kyley J.
    Porucznik, Christina A.
    Wilkins, Diana G.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2014, 953 : 53 - 61
  • [32] High throughput identification and quantification of 16 antipsychotics and 8 major metabolites in serum using ultra-high performance liquid chromatography-tandem mass spectrometry
    Patteet, Lisbeth
    Maudens, Kristof E.
    Sabbe, Bernard
    Morrens, Manuel
    De Doncker, Mireille
    Neels, Hugo
    CLINICA CHIMICA ACTA, 2014, 429 : 51 - 58
  • [33] Validation of a rapid ultra-high-performance liquid chromatography-tandem mass spectrometry method for quantification of chlorogenic acids in roasted coffee
    Colomban, Silvia
    Guercia, Elena
    Navarini, Luciano
    JOURNAL OF MASS SPECTROMETRY, 2020, 55 (11):
  • [34] Direct injection liquid chromatography-tandem mass spectrometry as a sensitive and high-throughput method for the quantitative surveillance of antimicrobials in wastewater
    Li, Jinglong
    Shimko, Katja M.
    He, Chang
    Patterson, Brad
    Bade, Richard
    Shiels, Ryan
    Mueller, Jochen F.
    Thomas, Kevin, V
    O'Brien, Jake W.
    SCIENCE OF THE TOTAL ENVIRONMENT, 2023, 900
  • [35] Development and validation of an ultra performance liquid chromatography-tandem mass spectrometry method for twelve bisphenol compounds in animal feed
    Wang, Ruiguo
    Dong, Shujun
    Wang, Peilong
    Li, Tong
    Huang, Yuan
    Zhao, Lijuan
    Su, Xiaoou
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2021, 1178
  • [36] Validated liquid chromatography-tandem mass spectrometry method for quantification of ticagrelor and its active metabolite in human plasma
    Xu, Xiaomin
    Ding, Xiaohong
    Yuan, Bo
    Li, Weiwei
    Wang, Yimei
    Jin, Yi
    Xu, Haiyan
    BIOMEDICAL CHROMATOGRAPHY, 2019, 33 (06)
  • [37] Multiplexed quantification of venlafaxine and metabolites in human plasma by liquid chromatography-tandem mass spectrometry
    Pandey, Aashish
    Price, Amelia
    Ayala-Lopez, Nadia
    Garza, Kyana Y.
    Marzinke, Mark A.
    Knezevic, Claire E.
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2024, 243
  • [38] Quantitation of lovastatin and its hydroxy acid in human plasma by high-performance liquid chromatography-tandem mass spectrometry
    Guan, Xin
    Yin, Lei
    Yang, Yan
    Meng, Xiang-Jun
    Wang, De-Li
    Sun, Yan-Tong
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2018, 41 (10) : 668 - 675
  • [39] Development and validation of a liquid chromatography-tandem mass spectrometry assay for determination of raloxifene and its metabolites in human plasma
    Trontelj, Jurij
    Bogataj, Marija
    Marc, Janja
    Mrhar, Ales
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2007, 855 (02): : 220 - 227
  • [40] Quantification of levetiracetam in plasma of neonates by ultra performance liquid chromatography-tandem mass spectrometry
    Blonk, Maren I.
    van der Nagel, Bart C.
    Smit, Liesbeth S.
    Mathot, Ron A. A.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2010, 878 (7-8): : 675 - 681