High-Throughput Ultra Performance Liquid Chromatography-Tandem Mass Spectrometry Method Validation for the Estimation of Atorvastatin and Active Metabolites in Human Plasma

被引:0
|
作者
Agrawal, Nikhil [1 ]
Mittal, Amit [1 ,2 ,3 ]
机构
[1] Lovely Profess Univ, Sch Pharmaceut Sci, Dept Pharmaceut Chem, Phagwara, India
[2] Desh Bhagat Univ, Fac Pharmaceut Sci, Dept Pharmaceut Chem, Mandi Gobindgarh, India
[3] Lovely Profess Univ, Sch Pharmaceut Sci, Dept Pharmaceut Chem, Jalandhar Delhi GT Rd NH 44, Phagwara 144411, Punjab, India
关键词
atorvastatin; active metabolites; ultra high-performance liquid chromatography-liquid chromatography; mass spectrometry; bioanalytical; method validation (UPLC-MS; MS); PARA-HYDROXY ATORVASTATIN; LC-MS/MS; SIMULTANEOUS QUANTIFICATION; MS; QUANTITATION;
D O I
10.1089/adt.2022.113
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A highly selective, sensitive, rugged, and rapid ultra high-performance liquid chromatography-tandem mass spectrometry method (UPLC-MS/MS) is optimized and validated for reliable quantification of atorvastatin (ATR) and its active metabolites, 2-hydroxy atorvastatin (2-ATR) and 4-hydroxy atorvastatin (4-ATR) in human plasma using atorvastatin-D5 (ATR-D5), 2-hydroxy atorvastatin-D5 (2-ATR-D5), and 4-hydroxy atorvastatin-D5 (4-ATR-D5) as deuterium-labeled internal standards (ISTDs), respectively. Isocratic mode chromatographic separation was used with a reverse-phase C-18 Symmetry Shield (150 x 4.6 mm, 5.0 mu m) column and a mobile phase of acetonitrile:2 mM ammonium formate (pH-3.0) [65:35%v/v] at a flow rate of 0.7 mL/min. Electrospray ionization technique with positive ion mode polarity was applied to achieve the best signal intensity and stable response. Solid-phase extraction by direct elution method was applied to extract the drugs from the plasma sample. The calibration curve range was validated from a concentration range of 0.500-250 ng/mL for ATR and 2-ATR and 0.200-20 ng/mL for 4-ATR. The within-batch and between-batch precision and accuracy were found to be consistent and reproducible for all the analytes across the validation. Extraction recoveries were >80% for all analytes and ISTDs. All peaks of analytes and the respective ISTDs were eluted within 5.2 min. In this validated method, selective multivariate analytical approaches were utilized such as best fit linearity range for different strength formulations, preventive measures for in vivo and ex vivo autodegradation of metabolites, and shorter analysis time. This validated method can be useful for challenging quantification of ATR and its active metabolites for therapeutic drug monitoring and in high-throughput clinical study sample analysis.
引用
收藏
页码:110 / 125
页数:16
相关论文
共 50 条
  • [1] Development and Validation of a Liquid Chromatography-Tandem Mass Spectrometry Method for the Estimation of Rivaroxaban in Human Plasma
    Pathan, Mudassarahemadkhan
    Kshirsagar, Ajay
    ANALYTICAL CHEMISTRY LETTERS, 2020, 10 (06) : 876 - 889
  • [2] HIGH-THROUGHPUT DETERMINATION OF LINEZOLID IN HUMAN PLASMA BY LIQUID CHROMATOGRAPHY-TANDEM MASS SPECTROMETRY
    Vlase, Laurian
    Muntean, Dana
    Cuciureanu, Magdalena
    Cuciureanu, Rodica
    Gocan, Simion
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2011, 34 (08) : 591 - 600
  • [3] HIGH-THROUGHPUT DETERMINATION OF LINEZOLID IN HUMAN PLASMA BY LIQUID CHROMATOGRAPHY-TANDEM MASS SPECTROMETRY
    Vlase, Laurian
    Muntean, Dana
    Cuciureanu, Magdalena
    Cuciureanu, Rodica
    Gocan, Simion
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2011, 34 (06) : 436 - 445
  • [4] High-throughput analysis of ramelteon, agomelatine, and melatonin in human plasma by ultra-performance liquid chromatography-tandem mass spectrometry
    Ogawa, Tadashi
    Iwai, Masae
    Hattori, Hideki
    Zaitsu, Kei
    Kumazawa, Takeshi
    Ishii, Akira
    Suzuki, Osamu
    Seno, Hiroshi
    FORENSIC TOXICOLOGY, 2014, 32 (01) : 126 - 131
  • [5] High-throughput plasma docetaxel quantification by liquid chromatography-tandem mass spectrometry
    Corona, Giuseppe
    Elia, Caterina
    Casetta, Bruno
    Frustaci, Sergio
    Toffoli, Giuseppe
    CLINICA CHIMICA ACTA, 2011, 412 (3-4) : 358 - 364
  • [6] An ultra high performance liquid chromatography-tandem mass spectrometry method for the quantification of linagliptin in human plasma
    Nannapaneni, Nagaraj Kumar
    Jalalpure, Sunil S.
    Muppavarapu, Rajendraprasad
    Sirigiri, Sunil Kumar
    RSC ADVANCES, 2016, 6 (71): : 66756 - 66766
  • [7] Simultaneous quantification of atorvastatin and active metabolites in human plasma by liquid chromatography-tandem mass spectrometry using rosuvastatin as internal standard
    Nirogi, Ramakrishna V. S.
    Kandikere, Vishwottam N.
    Shukla, Manoj
    Mudigonda, Koteshwara
    Maurya, Santosh
    Boosi, Ravikurnar
    Anjaneyulu, Yerramilli
    BIOMEDICAL CHROMATOGRAPHY, 2006, 20 (09) : 924 - 936
  • [8] Direct injection ultra-performance liquid chromatography-tandem mass spectrometry for the high-throughput determination of 11 illicit drugs and metabolites in wastewater
    Ren, Hang
    Yuan, Shuai
    Zheng, Jiaming
    Luo, Ruxin
    Qiang, Huosheng
    Duan, Wenjia
    Zhao, Yunli
    Xiang, Ping
    JOURNAL OF CHROMATOGRAPHY A, 2022, 1685
  • [9] Quantitative Method Validation for the Analysis of 27 Antidepressants and Metabolites in Plasma With Ultraperformance Liquid Chromatography-Tandem Mass Spectrometry
    Ramirez Fernandez, Maria del Mar
    Wille, Sarah M. R.
    Samyn, Nele
    THERAPEUTIC DRUG MONITORING, 2012, 34 (01) : 11 - 24
  • [10] Sensitive, High-Throughput Liquid Chromatography-Tandem Mass Spectrometry Analysis of Atorvastatin and Its Pharmacologically Active Metabolites in Serum for Supporting Precision Pharmacotherapy
    Karvaly, Gellert Balazs
    Vincze, Istvan
    Karadi, Istvan
    Vasarhelyi, Barna
    Zsary, Andras
    MOLECULES, 2021, 26 (05):