An analytical model of lateral condylar plate working length

被引:0
|
作者
Roytman, Gregory R. [1 ,2 ,4 ]
Beitler, Brian [1 ]
LaMonica, Julia [1 ]
Spero, Matthew [1 ]
Toy, Kendal [1 ]
Ramji, Alim F. [1 ]
Yoo, Brad [1 ]
Leslie, Michael P. [1 ]
Baumgaertner, Michael [1 ]
Tommasini, Steven M. [1 ,2 ]
Wiznia, Daniel H. [1 ,3 ]
机构
[1] Yale Univ, Sch Med, Orthopaed & Rehabil, 47 Coll Pl, New Haven, CT 06510 USA
[2] Yale Univ, Sch Engn & Appl Sci, Biomed Engn, 17 Hillhouse Ave, New Haven, CT 06520 USA
[3] Yale Univ, Sch Engn & Appl Sci, Mech Engn & Mat Sci, 17 Hillhouse Ave, New Haven, CT 06520 USA
[4] Farnham Mem Bldg FMB Room, 330 Cedar St, New Haven, CT 06510 USA
基金
美国国家卫生研究院;
关键词
Distal femur fracture; Lateral condylar plate; Dynamic condylar screw; Finite element analysis; Analytical model; FINITE-ELEMENT-ANALYSIS; DISTAL FEMUR FRACTURES; LOCKING PLATES; TRABECULAR BONE; PROXIMAL FEMUR; STABILITY; MORTALITY; FIXATION; CONFIGURATION; STIFFNESS;
D O I
10.1016/j.clinbiomech.2023.106129
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background: The locking plate is a common device to treat distal femur fractures. Healing is affected by construct stiffness, thus many surgeon-controlled variables such as working length have been examined for their effects on strain at the fracture. No convenient analytical model which aids surgeons in determining working length has yet been described. We propose an analytical model and compare it to finite element analysis and cadaveric biomechanical testing.Methods: First, an analytical model based on a cantilever beam equation was derived. Next, a finite element model was developed based on a CT scan of a "fresh-frozen" cadaveric femur. Third, biomechanical testing in single-leg stance loading was performed on the cadaver. In all methods, strain at the fracture was recorded. An ANCOVA test was conducted to compare the strains.Findings: In all models, as the working length increased so did strain. For strain at the fracture, the shortest working length (35 mm) had a strain of 8% in the analytical model, 9% in the finite element model, and 7% for the cadaver. The longest working length (140 mm) demonstrated strain of 15% in the analytical model, and the finite element and biomechanical tests both demonstrated strain of 14%.Interpretation: The strain predicted by the analytical model was consistent with the strain observed in both the finite element and biomechanical models. As demonstrated in existing literature, increasing the working length increases strain at the fracture site. Additional work is required to refine and establish validity and reliability of the analytical model.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] Application of a lateral intertubercular sulcus plate in the treatment of proximal humeral fractures: a finite element analysis
    Li, Dong
    Lv, WenXue
    Chen, WenMing
    Meng, Jing
    Liu, Song
    Duan, ZongKang
    Yu, Bo
    BMC SURGERY, 2022, 22 (01)
  • [42] Distal Femoral Fixation: A Biomechanical Comparison of Trigen Retrograde Intramedullary (IM) Nail, Dynamic Condylar Screw (DCS), and Locking Compression Plate (LCP) Condylar Plate
    Heiney, Jake P.
    Barnett, Michael D.
    Vrabec, Gregory A.
    Schoenfeld, Andrew J.
    Baji, Avinash
    Njus, Glen O.
    JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2009, 66 (02): : 443 - 449
  • [43] Analytical Model Development for CLT Diaphragms Loaded Perpendicular to the Length of Panels
    Fakhrzarei, Mahboobeh
    Daneshvar, Hossein
    Chui, Ying Hei
    JOURNAL OF STRUCTURAL ENGINEERING, 2023, 149 (06)
  • [44] Contradictory working length effects in locked plating of the distal and middle femoral fractures a biomechanical study
    Chao, Ching-Kong
    Chen, You-Lin
    Wu, Jian-Ming
    Lin, Chen-Huei
    Chuang, Ting-Yu
    Lin, Jinn
    CLINICAL BIOMECHANICS, 2020, 80
  • [45] A New Curvature Analytical Method in Plate Leveling Process
    Liu, Zhifang
    Luo, Yuanxin
    Wang, Yongqin
    Liao, Thunshun Warren
    ISIJ INTERNATIONAL, 2018, 58 (06) : 1094 - 1101
  • [46] A Biomechanical Comparison of Three 1.5-mm Plate and Screw Configurations and a Single 2.0-mm Plate for Internal Fixation of a Mandibular Condylar Fracture
    Aquilina, Peter
    Parr, William C. H.
    Chamoli, Uphar
    Wroe, Stephen
    Clausen, Philip
    CRANIOMAXILLOFACIAL TRAUMA & RECONSTRUCTION, 2014, 7 (03) : 208 - 213
  • [47] Mini-Blade Plate to Obtain Length Across Lateral Malleolus Fractures: Surgical Technique and Biomechanical Evaluation
    Kadar, Assaf
    Tommasini, Steven M.
    Singla, Amit
    Beitler, Brian G.
    Moushey, Alexander M.
    Baumgaertner, Michael R.
    INDIAN JOURNAL OF ORTHOPAEDICS, 2022, 56 (04) : 573 - 579
  • [48] Lateral torsional buckling of STEEL beams strengthened with GFRP plate
    Phe Van Pham
    Mohareb, Magdi
    Fam, Amir
    THIN-WALLED STRUCTURES, 2018, 131 : 55 - 75
  • [49] Analytical Model and Analysis of Spiral-Coil EMAT Above a Ferromagnetic Plate
    Li, Yong
    Liu, Ze
    Yuan, Wei
    Zhao, Pengfei
    Yue, Yuanli
    IEEE TRANSACTIONS ON MAGNETICS, 2020, 56 (09)
  • [50] Effects of lateral load on warm prestressing in a center crack plate
    Ayatollahi, M. R.
    Aliniaziazi, A.
    MATERIALS SCIENCE AND ENGINEERING A-STRUCTURAL MATERIALS PROPERTIES MICROSTRUCTURE AND PROCESSING, 2006, 441 (1-2): : 170 - 175