An analytical model of lateral condylar plate working length

被引:0
|
作者
Roytman, Gregory R. [1 ,2 ,4 ]
Beitler, Brian [1 ]
LaMonica, Julia [1 ]
Spero, Matthew [1 ]
Toy, Kendal [1 ]
Ramji, Alim F. [1 ]
Yoo, Brad [1 ]
Leslie, Michael P. [1 ]
Baumgaertner, Michael [1 ]
Tommasini, Steven M. [1 ,2 ]
Wiznia, Daniel H. [1 ,3 ]
机构
[1] Yale Univ, Sch Med, Orthopaed & Rehabil, 47 Coll Pl, New Haven, CT 06510 USA
[2] Yale Univ, Sch Engn & Appl Sci, Biomed Engn, 17 Hillhouse Ave, New Haven, CT 06520 USA
[3] Yale Univ, Sch Engn & Appl Sci, Mech Engn & Mat Sci, 17 Hillhouse Ave, New Haven, CT 06520 USA
[4] Farnham Mem Bldg FMB Room, 330 Cedar St, New Haven, CT 06510 USA
基金
美国国家卫生研究院;
关键词
Distal femur fracture; Lateral condylar plate; Dynamic condylar screw; Finite element analysis; Analytical model; FINITE-ELEMENT-ANALYSIS; DISTAL FEMUR FRACTURES; LOCKING PLATES; TRABECULAR BONE; PROXIMAL FEMUR; STABILITY; MORTALITY; FIXATION; CONFIGURATION; STIFFNESS;
D O I
10.1016/j.clinbiomech.2023.106129
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background: The locking plate is a common device to treat distal femur fractures. Healing is affected by construct stiffness, thus many surgeon-controlled variables such as working length have been examined for their effects on strain at the fracture. No convenient analytical model which aids surgeons in determining working length has yet been described. We propose an analytical model and compare it to finite element analysis and cadaveric biomechanical testing.Methods: First, an analytical model based on a cantilever beam equation was derived. Next, a finite element model was developed based on a CT scan of a "fresh-frozen" cadaveric femur. Third, biomechanical testing in single-leg stance loading was performed on the cadaver. In all methods, strain at the fracture was recorded. An ANCOVA test was conducted to compare the strains.Findings: In all models, as the working length increased so did strain. For strain at the fracture, the shortest working length (35 mm) had a strain of 8% in the analytical model, 9% in the finite element model, and 7% for the cadaver. The longest working length (140 mm) demonstrated strain of 15% in the analytical model, and the finite element and biomechanical tests both demonstrated strain of 14%.Interpretation: The strain predicted by the analytical model was consistent with the strain observed in both the finite element and biomechanical models. As demonstrated in existing literature, increasing the working length increases strain at the fracture site. Additional work is required to refine and establish validity and reliability of the analytical model.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] An analytical model for predicting the lateral-torsion coupling property of laminated rubber bearings
    Zhou, Fangyuan
    Zhang, Zixiang
    Wu, Dongdong
    Zhu, Hongping
    JOURNAL OF SOUND AND VIBRATION, 2018, 427 : 1 - 14
  • [22] Comparison of locking and non-locking reconstruction plate-screw system in lateral mandibular defects by finite element analysis
    Muftuoglu, G.
    Bayram, B.
    Aydin, P.
    JOURNAL OF STOMATOLOGY ORAL AND MAXILLOFACIAL SURGERY, 2021, 122 (04) : E65 - E69
  • [23] Salvage procedures for trochanteric femoral fractures after internal fixation failure: Biomechanical comparison of a plate fixator and the dynamic condylar screw
    Konstantinidis, L.
    Papaioannou, C.
    Mehlhorn, A.
    Hirschmueller, A.
    Suedkamp, N. P.
    Helwig, P.
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2011, 225 (H7) : 710 - 717
  • [24] Potential problem and solution of lateral plate postposition for the posterolateral tibial plateau fracture
    Hu, Zhenghui
    Ren, Weizhi
    Zhang, Wen
    Li, Liubing
    Xu, Wei
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2023, 18 (01)
  • [25] Resorbable triangular plate for osteosynthesis of fractures of the condylar neck
    Lauer, Guenter
    Pradel, Winnie
    Leonhardt, Henry
    Loukota, Richard
    Eckelt, Uwe
    BRITISH JOURNAL OF ORAL & MAXILLOFACIAL SURGERY, 2010, 48 (07) : 532 - 535
  • [26] A two dimensional analytical model for the current distribution in a lateral IGBT
    Henkel, I
    Feiler, W
    Kostka, A
    SOLID-STATE ELECTRONICS, 2001, 45 (10) : 1725 - 1732
  • [27] An analytical model for fracture initiation from radial lateral borehole
    Liu Qingling
    Tian Shouceng
    Li Gensheng
    Sheng Mao
    Li Xiaojiang
    Wang Tianyu
    Shen Zhonghou
    JOURNAL OF PETROLEUM SCIENCE AND ENGINEERING, 2018, 164 : 206 - 218
  • [28] A verification of analytical model of vibrations of sandwich plate with honeycomb core
    Marczak, Jakub
    COMPUTERS & STRUCTURES, 2025, 311
  • [29] Analytical model and repetitive working characteristics of plasma synthetic jet
    Zong, Haohua
    Wu, Yun
    Song, Huimin
    Li, Yinghong
    Zhang, Zhibo
    Hangkong Xuebao/Acta Aeronautica et Astronautica Sinica, 2015, 36 (06): : 1762 - 1774
  • [30] Analytical Model of Small Hydropower Plant Working at Variable Speed
    Borkowski, Dariusz
    IEEE TRANSACTIONS ON ENERGY CONVERSION, 2018, 33 (04) : 1886 - 1894