An analytical model of lateral condylar plate working length

被引:0
|
作者
Roytman, Gregory R. [1 ,2 ,4 ]
Beitler, Brian [1 ]
LaMonica, Julia [1 ]
Spero, Matthew [1 ]
Toy, Kendal [1 ]
Ramji, Alim F. [1 ]
Yoo, Brad [1 ]
Leslie, Michael P. [1 ]
Baumgaertner, Michael [1 ]
Tommasini, Steven M. [1 ,2 ]
Wiznia, Daniel H. [1 ,3 ]
机构
[1] Yale Univ, Sch Med, Orthopaed & Rehabil, 47 Coll Pl, New Haven, CT 06510 USA
[2] Yale Univ, Sch Engn & Appl Sci, Biomed Engn, 17 Hillhouse Ave, New Haven, CT 06520 USA
[3] Yale Univ, Sch Engn & Appl Sci, Mech Engn & Mat Sci, 17 Hillhouse Ave, New Haven, CT 06520 USA
[4] Farnham Mem Bldg FMB Room, 330 Cedar St, New Haven, CT 06510 USA
基金
美国国家卫生研究院;
关键词
Distal femur fracture; Lateral condylar plate; Dynamic condylar screw; Finite element analysis; Analytical model; FINITE-ELEMENT-ANALYSIS; DISTAL FEMUR FRACTURES; LOCKING PLATES; TRABECULAR BONE; PROXIMAL FEMUR; STABILITY; MORTALITY; FIXATION; CONFIGURATION; STIFFNESS;
D O I
10.1016/j.clinbiomech.2023.106129
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background: The locking plate is a common device to treat distal femur fractures. Healing is affected by construct stiffness, thus many surgeon-controlled variables such as working length have been examined for their effects on strain at the fracture. No convenient analytical model which aids surgeons in determining working length has yet been described. We propose an analytical model and compare it to finite element analysis and cadaveric biomechanical testing.Methods: First, an analytical model based on a cantilever beam equation was derived. Next, a finite element model was developed based on a CT scan of a "fresh-frozen" cadaveric femur. Third, biomechanical testing in single-leg stance loading was performed on the cadaver. In all methods, strain at the fracture was recorded. An ANCOVA test was conducted to compare the strains.Findings: In all models, as the working length increased so did strain. For strain at the fracture, the shortest working length (35 mm) had a strain of 8% in the analytical model, 9% in the finite element model, and 7% for the cadaver. The longest working length (140 mm) demonstrated strain of 15% in the analytical model, and the finite element and biomechanical tests both demonstrated strain of 14%.Interpretation: The strain predicted by the analytical model was consistent with the strain observed in both the finite element and biomechanical models. As demonstrated in existing literature, increasing the working length increases strain at the fracture site. Additional work is required to refine and establish validity and reliability of the analytical model.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Clinical Assessment of a Lateral Epicondylar Anatomical Plate for the Stabilization of Humeral Condylar Fractures in Dogs
    Jones, Rebecca L.
    Tomlinson, Andrew W.
    Barnes, Duncan M.
    Hood, Rebecca S.
    McClement, Jamie P.
    Ogden, Daniel M.
    Owen, Mark A.
    Onyett, Jeremy R.
    Walton, Myles B.
    VETERINARY AND COMPARATIVE ORTHOPAEDICS AND TRAUMATOLOGY, 2024, 37 (05) : 243 - 250
  • [2] Working length and proximal screw constructs in plate osteosynthesis of distal femur fractures
    Harvin, William H.
    Oladeji, Lasun O.
    Della Rocca, Gregory J.
    Murtha, Yvonne M.
    Volgas, David A.
    Stannard, James P.
    Crist, Brett D.
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2017, 48 (11): : 2597 - 2601
  • [3] An osteosynthesis plate analytical model
    Kenedi, Paulo Pedro
    Vignoli, Lucas Lisboa
    JOURNAL OF THE BRAZILIAN SOCIETY OF MECHANICAL SCIENCES AND ENGINEERING, 2017, 39 (03) : 645 - 659
  • [4] Semi-rigid screws provide an auxiliary option to plate working length to control interfragmentary movement in locking plate fixation at the distal femur
    Heyland, Mark
    Duda, Georg N.
    Haas, Norbert P.
    Trepczynski, Adam
    Doebele, Stefan
    Hoentzsch, Dankward
    Schaser, Klaus-Dieter
    Maerdian, Sven
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2015, 46 : S24 - S32
  • [5] Effect of an Orthogonal Locking Plate and Primary Plate Working Length on Construct Stiffness and Plate Strain in an In vitro Fracture-Gap Model
    de Bruyn, Brett Walter
    Glyde, Mark
    Day, Robert
    Hosgood, Giselle
    VETERINARY AND COMPARATIVE ORTHOPAEDICS AND TRAUMATOLOGY, 2024, 37 (04) : 173 - 180
  • [6] An osteosynthesis plate analytical model
    Paulo Pedro Kenedi
    Lucas Lisboa Vignoli
    Journal of the Brazilian Society of Mechanical Sciences and Engineering, 2017, 39 : 645 - 659
  • [7] Effect of plate working length on plate stiffness and cyclic fatigue life in a cadaveric femoral fracture gap model stabilized with a 12-hole 2.4 mm locking compression plate
    Chao, Peini
    Conrad, Bryan P.
    Lewis, Daniel D.
    Horodyski, MaryBeth
    Pozzi, Antonio
    BMC VETERINARY RESEARCH, 2013, 9
  • [8] Effect of Plate-Bone Distance and Working Length on 2.0-mm Locking Construct Stiffness and Plate Strain in a Diaphyseal Fracture Gap Model: A Biomechanical Study
    Evans, Alecia
    Glyde, Mark
    Day, Rob
    Hosgood, Giselle
    VETERINARY AND COMPARATIVE ORTHOPAEDICS AND TRAUMATOLOGY, 2024, 37 (01) : 1 - 7
  • [9] Outcomes of distal femoral fractures treated with dynamic condylar screw (DCS) plate system: a single centre experience spanning 15 years
    Lemsanni, Meryem
    Najeb, Youssef
    PAN AFRICAN MEDICAL JOURNAL, 2021, 38
  • [10] The effect of intramedullary pin size and plate working length on plate strain in locking compression platerod constructs under axial load
    Pearson, Tim
    Glyde, Mark R.
    Day, Robert E.
    Hosgood, Giselle L.
    VETERINARY AND COMPARATIVE ORTHOPAEDICS AND TRAUMATOLOGY, 2016, 29 (06) : 451 - 458