Evaluation of kernel low-rank compressed sensing in preclinical diffusion magnetic resonance imaging

被引:1
|
作者
de Souza, Diego Alves Rodrigues [1 ]
Mathieu, Herve [1 ,2 ]
Deloulme, Jean-Christophe [1 ]
Barbier, Emmanuel L. [1 ,2 ]
机构
[1] Univ Grenoble Alpes, Grenoble Inst Neurosci, INSERM, U1216, Grenoble, France
[2] Univ Grenoble Alpes, INSERM, US17, CNRS,UAR 3552,CHU Grenoble Alpes, Grenoble, France
关键词
diffusion MRI; compressed sensing (CS); kernel principal component analysis; mouse brain; tractography; composite real PCA; microtubule-associated protein; Berkeley Advanced Reconstruction Toolbox (BART); IN-VIVO; MRI; BRAIN; TRACTOGRAPHY; CONNECTOME; MODEL;
D O I
10.3389/fnins.2023.1172830
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Compressed sensing (CS) is widely used to accelerate clinical diffusion MRI acquisitions, but it is not widely used in preclinical settings yet. In this study, we optimized and compared several CS reconstruction methods for diffusion imaging. Different undersampling patterns and two reconstruction approaches were evaluated: conventional CS, based on Berkeley Advanced Reconstruction Toolbox (BART-CS) toolbox, and a new kernel low-rank (KLR)-CS, based on kernel principal component analysis and low-resolution-phase (LRP) maps. 3D CS acquisitions were performed at 9.4T using a 4-element cryocoil on mice (wild type and a MAP6 knockout). Comparison metrics were error and structural similarity index measure (SSIM) on fractional anisotropy (FA) and mean diffusivity (MD), as well as reconstructions of the anterior commissure and fornix. Acceleration factors (AF) up to 6 were considered. In the case of retrospective undersampling, the proposed KLR-CS outperformed BART-CS up to AF = 6 for FA and MD maps and tractography. For instance, for AF = 4, the maximum errors were, respectively, 8.0% for BART-CS and 4.9% for KLR-CS, considering both FA and MD in the corpus callosum. Regarding undersampled acquisitions, these maximum errors became, respectively, 10.5% for BART-CS and 7.0% for KLR-CS. This difference between simulations and acquisitions arose mainly from repetition noise, but also from differences in resonance frequency drift, signal-to-noise ratio, and in reconstruction noise. Despite this increased error, fully sampled and AF = 2 yielded comparable results for FA, MD and tractography, and AF = 4 showed minor faults. Altogether, KLR-CS based on LRP maps seems a robust approach to accelerate preclinical diffusion MRI and thereby limit the effect of the frequency drift.
引用
收藏
页数:16
相关论文
共 50 条
  • [41] Pattern Synthesis for Sparse Arrays by Compressed Sensing and Low-Rank Matrix Recovery Methods
    Wang, Ting
    Xia, Ke-Wen
    Lu, Ning
    INTERNATIONAL JOURNAL OF ANTENNAS AND PROPAGATION, 2018, 2018
  • [42] Kernel Low-Rank Representation for face recognition
    Hoangvu Nguyen
    Yang, Wankou
    Shen, Fumin
    Sun, Changyin
    NEUROCOMPUTING, 2015, 155 : 32 - 42
  • [43] Kernel Locality Preserving Low-Rank Representation
    Pan, Yu-Qi
    Jiang, Ming-Yan
    Li, Fei
    JOURNAL OF INFORMATION SCIENCE AND ENGINEERING, 2016, 32 (06) : 1561 - 1574
  • [44] Noise power spectrum in compressed sensing magnetic resonance imaging
    Takahashi, Junji
    Machida, Yoshio
    Aoba, Minami
    Nawa, Yuki
    Kamoshida, Ryo
    Fukuzawa, Kei
    Ohmoto-Sekine, Yuki
    RADIOLOGICAL PHYSICS AND TECHNOLOGY, 2021, 14 (01) : 93 - 99
  • [45] Application of Compressed Sensing on Magnetic Resonance Imaging: A brief Survey
    Shrividya, G.
    Bharathi, S. H.
    2016 IEEE INTERNATIONAL CONFERENCE ON RECENT TRENDS IN ELECTRONICS, INFORMATION & COMMUNICATION TECHNOLOGY (RTEICT), 2016, : 2037 - 2041
  • [46] Curvelets as a Sparse Basis for Compressed Sensing Magnetic Resonance Imaging
    Smith, David S.
    Arlinghaus, Lori R.
    Yankeelov, Thomas E.
    Welch, E. Brian
    MEDICAL IMAGING 2013: IMAGE PROCESSING, 2013, 8669
  • [47] Noise power spectrum in compressed sensing magnetic resonance imaging
    Junji Takahashi
    Yoshio Machida
    Minami Aoba
    Yuki Nawa
    Ryo Kamoshida
    Kei Fukuzawa
    Yuki Ohmoto-Sekine
    Radiological Physics and Technology, 2021, 14 : 93 - 99
  • [48] Uncover This Tech Term: Compressed Sensing Magnetic Resonance Imaging
    Yoon, Sungjin
    Park, So Hyun
    Han, Dongyeob
    KOREAN JOURNAL OF RADIOLOGY, 2023, 24 (12) : 1293 - 1297
  • [49] SPREAD SPECTRUM FOR COMPRESSED SENSING TECHNIQUES IN MAGNETIC RESONANCE IMAGING
    Wiaux, Y.
    Puy, G.
    Gruetter, R.
    Thiran, J. -Ph.
    Van De Ville, D.
    Vandergheynst, P.
    2010 7TH IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: FROM NANO TO MACRO, 2010, : 756 - 759
  • [50] Phase-Constrained Parallel Magnetic Resonance Imaging Reconstruction Based on Low-Rank Matrix Completion
    Jiang, Longyu
    He, Runguo
    Liu, Jie
    Chen, Yang
    Wu, Jiasong
    Shu, Huazhong
    Coatrieux, Jean-Louis
    IEEE ACCESS, 2018, 6 : 4941 - 4954