Evaluation of kernel low-rank compressed sensing in preclinical diffusion magnetic resonance imaging

被引:1
|
作者
de Souza, Diego Alves Rodrigues [1 ]
Mathieu, Herve [1 ,2 ]
Deloulme, Jean-Christophe [1 ]
Barbier, Emmanuel L. [1 ,2 ]
机构
[1] Univ Grenoble Alpes, Grenoble Inst Neurosci, INSERM, U1216, Grenoble, France
[2] Univ Grenoble Alpes, INSERM, US17, CNRS,UAR 3552,CHU Grenoble Alpes, Grenoble, France
关键词
diffusion MRI; compressed sensing (CS); kernel principal component analysis; mouse brain; tractography; composite real PCA; microtubule-associated protein; Berkeley Advanced Reconstruction Toolbox (BART); IN-VIVO; MRI; BRAIN; TRACTOGRAPHY; CONNECTOME; MODEL;
D O I
10.3389/fnins.2023.1172830
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Compressed sensing (CS) is widely used to accelerate clinical diffusion MRI acquisitions, but it is not widely used in preclinical settings yet. In this study, we optimized and compared several CS reconstruction methods for diffusion imaging. Different undersampling patterns and two reconstruction approaches were evaluated: conventional CS, based on Berkeley Advanced Reconstruction Toolbox (BART-CS) toolbox, and a new kernel low-rank (KLR)-CS, based on kernel principal component analysis and low-resolution-phase (LRP) maps. 3D CS acquisitions were performed at 9.4T using a 4-element cryocoil on mice (wild type and a MAP6 knockout). Comparison metrics were error and structural similarity index measure (SSIM) on fractional anisotropy (FA) and mean diffusivity (MD), as well as reconstructions of the anterior commissure and fornix. Acceleration factors (AF) up to 6 were considered. In the case of retrospective undersampling, the proposed KLR-CS outperformed BART-CS up to AF = 6 for FA and MD maps and tractography. For instance, for AF = 4, the maximum errors were, respectively, 8.0% for BART-CS and 4.9% for KLR-CS, considering both FA and MD in the corpus callosum. Regarding undersampled acquisitions, these maximum errors became, respectively, 10.5% for BART-CS and 7.0% for KLR-CS. This difference between simulations and acquisitions arose mainly from repetition noise, but also from differences in resonance frequency drift, signal-to-noise ratio, and in reconstruction noise. Despite this increased error, fully sampled and AF = 2 yielded comparable results for FA, MD and tractography, and AF = 4 showed minor faults. Altogether, KLR-CS based on LRP maps seems a robust approach to accelerate preclinical diffusion MRI and thereby limit the effect of the frequency drift.
引用
收藏
页数:16
相关论文
共 50 条
  • [31] Compressed Sensing of Multichannel EEG Signals: The Simultaneous Cosparsity and Low-Rank Optimization
    Liu, Yipeng
    De Vos, Maarten
    Van Huffel, Sabine
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2015, 62 (08) : 2055 - 2061
  • [32] Parallel Magnetic Resonance Imaging Using Compressed Sensing
    Bilgin, Ali
    Kim, Yookyung
    Lalgudi, Hariharan G.
    Trouard, Theodore P.
    Altbach, Maria I.
    APPLICATIONS OF DIGITAL IMAGE PROCESSING XXXI, 2008, 7073
  • [33] OSCILLATE: A low-rank approach for accelerated magnetic resonance elastography
    McIlvain, Grace
    Cerjanic, Alexander M.
    Christodoulou, Anthony G.
    McGarry, Matthew D. J.
    Johnson, Curtis L.
    MAGNETIC RESONANCE IN MEDICINE, 2022, 88 (04) : 1659 - 1672
  • [34] An improved low-rank plus sparse unrolling network method for dynamic magnetic resonance imaging
    Jiang, Ming-feng
    Chen, Yun-jiang
    Ruan, Dong-sheng
    Yuan, Zi-han
    Zhang, Ju-cheng
    Xia, Ling
    MEDICAL PHYSICS, 2024,
  • [35] Field-Inhomogeneity-Corrected Low-Rank Filtering of Magnetic Resonance Spectroscopic Imaging Data
    Liu, Yan
    Ma, Chao
    Clifford, Bryan
    Lam, Fan
    Johnson, Curtis L.
    Liang, Zhi-Pei
    2014 36TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2014, : 6422 - 6425
  • [36] Low-Rank and Sparse Matrix Decomposition for Compressed Sensing Reconstruction of Magnetic Resonance 4D Phase Contrast Blood Flow Imaging (LoSDeCoS 4D-PCI)
    Hutter, Jana
    Schmitt, Peter
    Aandal, Gunhild
    Greiser, Andreas
    Forman, Christoph
    Grimm, Robert
    Hornegger, Joachim
    Maier, Andreas
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION (MICCAI 2013), PT I, 2013, 8149 : 558 - 565
  • [37] Manifold Recovery Using Kernel Low-Rank Regularization: Application to Dynamic Imaging
    Poddar, Sunrita
    Mohsin, Yasir Q.
    Ansah, Deidra
    Thattaliyath, Bijoy
    Ashwath, Ravi
    Jacob, Mathews
    IEEE TRANSACTIONS ON COMPUTATIONAL IMAGING, 2019, 5 (03): : 478 - 491
  • [38] KERNEL OPTIMIZATION FOR LOW-RANK MULTIFIDELITY ALGORITHMS
    Razi, Mani
    Kirby, Robert M.
    Narayan, Akil
    INTERNATIONAL JOURNAL FOR UNCERTAINTY QUANTIFICATION, 2021, 11 (01) : 31 - 54
  • [39] Low-Rank Combined Adaptive Sparsifying Transform for Blind Compressed Sensing Image Recovery
    HE Ning
    WANG Ruolin
    LYU Jiayi
    XUE Jian
    Chinese Journal of Electronics, 2020, 29 (04) : 678 - 685
  • [40] Low-Rank Combined Adaptive Sparsifying Transform for Blind Compressed Sensing Image Recovery
    He, Ning
    Wang, Ruolin
    Lyu, Jiayi
    Xue, Jian
    CHINESE JOURNAL OF ELECTRONICS, 2020, 29 (04) : 678 - 685