Evaluation of kernel low-rank compressed sensing in preclinical diffusion magnetic resonance imaging

被引:1
|
作者
de Souza, Diego Alves Rodrigues [1 ]
Mathieu, Herve [1 ,2 ]
Deloulme, Jean-Christophe [1 ]
Barbier, Emmanuel L. [1 ,2 ]
机构
[1] Univ Grenoble Alpes, Grenoble Inst Neurosci, INSERM, U1216, Grenoble, France
[2] Univ Grenoble Alpes, INSERM, US17, CNRS,UAR 3552,CHU Grenoble Alpes, Grenoble, France
关键词
diffusion MRI; compressed sensing (CS); kernel principal component analysis; mouse brain; tractography; composite real PCA; microtubule-associated protein; Berkeley Advanced Reconstruction Toolbox (BART); IN-VIVO; MRI; BRAIN; TRACTOGRAPHY; CONNECTOME; MODEL;
D O I
10.3389/fnins.2023.1172830
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Compressed sensing (CS) is widely used to accelerate clinical diffusion MRI acquisitions, but it is not widely used in preclinical settings yet. In this study, we optimized and compared several CS reconstruction methods for diffusion imaging. Different undersampling patterns and two reconstruction approaches were evaluated: conventional CS, based on Berkeley Advanced Reconstruction Toolbox (BART-CS) toolbox, and a new kernel low-rank (KLR)-CS, based on kernel principal component analysis and low-resolution-phase (LRP) maps. 3D CS acquisitions were performed at 9.4T using a 4-element cryocoil on mice (wild type and a MAP6 knockout). Comparison metrics were error and structural similarity index measure (SSIM) on fractional anisotropy (FA) and mean diffusivity (MD), as well as reconstructions of the anterior commissure and fornix. Acceleration factors (AF) up to 6 were considered. In the case of retrospective undersampling, the proposed KLR-CS outperformed BART-CS up to AF = 6 for FA and MD maps and tractography. For instance, for AF = 4, the maximum errors were, respectively, 8.0% for BART-CS and 4.9% for KLR-CS, considering both FA and MD in the corpus callosum. Regarding undersampled acquisitions, these maximum errors became, respectively, 10.5% for BART-CS and 7.0% for KLR-CS. This difference between simulations and acquisitions arose mainly from repetition noise, but also from differences in resonance frequency drift, signal-to-noise ratio, and in reconstruction noise. Despite this increased error, fully sampled and AF = 2 yielded comparable results for FA, MD and tractography, and AF = 4 showed minor faults. Altogether, KLR-CS based on LRP maps seems a robust approach to accelerate preclinical diffusion MRI and thereby limit the effect of the frequency drift.
引用
收藏
页数:16
相关论文
共 50 条
  • [1] Acceleration of three-dimensional diffusion magnetic resonance imaging using a kernel low-rank compressed sensing method
    Zhang, Chaoyi
    Arefin, Tanzil Mahmud
    Nakarmi, Ukash
    Lee, Choong Heon
    Li, Hongyu
    Liang, Dong
    Zhang, Jiangyang
    Ying, Leslie
    NEUROIMAGE, 2020, 210
  • [2] Cardiac diffusion tensor imaging based on compressed sensing using joint sparsity and low-rank approximation
    Huang, Jianping
    Wang, Lihui
    Chu, Chunyu
    Zhang, Yanli
    Liu, Wanyu
    Zhu, Yuemin
    TECHNOLOGY AND HEALTH CARE, 2016, 24 : S593 - S599
  • [3] Low-rank plus sparse compressed sensing for accelerated proton resonance frequency shift MR temperature imaging
    Cao, Zhipeng
    Gore, John C.
    Grissom, William A.
    MAGNETIC RESONANCE IN MEDICINE, 2019, 81 (06) : 3555 - 3566
  • [4] Compressed sensing of low-rank plus sparse matrices
    Tanner, Jared
    Vary, Simon
    APPLIED AND COMPUTATIONAL HARMONIC ANALYSIS, 2023, 64 : 254 - 293
  • [5] Low-rank magnetic resonance fingerprinting
    Mazor, Gal
    Weizman, Lior
    Tal, Assaf
    Eldar, Yonina C.
    MEDICAL PHYSICS, 2018, 45 (09) : 4066 - 4084
  • [6] Dynamic Magnetic Resonance Imaging using Compressed Sensing with Multi-scale Low Rank Penalty
    Mangova, Marie
    Rajmic, Pavel
    Jirik, Radovan
    2017 40TH INTERNATIONAL CONFERENCE ON TELECOMMUNICATIONS AND SIGNAL PROCESSING (TSP), 2017, : 780 - 783
  • [7] On Identity Testing of Tensors, Low-rank Recovery and Compressed Sensing
    Forbes, Michael A.
    Shpilka, Amir
    STOC'12: PROCEEDINGS OF THE 2012 ACM SYMPOSIUM ON THEORY OF COMPUTING, 2012, : 163 - 171
  • [8] Low-rank and sparse reconstruction for fast diffusion nuclear magnetic resonance spectroscopy
    Guo, Di
    Zhan, Jiaying
    Zhou, Yirong
    Tu, Zhangren
    Zhang, Zifei
    Chen, Zhong
    Qu, Xiaobo
    IET SIGNAL PROCESSING, 2021, 15 (02) : 88 - 97
  • [9] Generalized Nonconvex Low-Rank Algorithm for Magnetic Resonance Imaging (MRI) Reconstruction
    吴新峰
    刘且根
    卢红阳
    龙承志
    王玉皞
    JournalofDonghuaUniversity(EnglishEdition), 2017, 34 (02) : 316 - 321
  • [10] Dynamic Magnetic Resonance Imaging via Nonconvex Low-Rank Matrix Approximation
    Xu, Fei
    Han, Jingqi
    Wang, Yongli
    Chen, Ming
    Chen, Yongyong
    He, Guoping
    Hu, Yunhong
    IEEE ACCESS, 2017, 5 : 1958 - 1966