INDOOR AIR QUALITY ASSESSMENT AT A PLASTIC-TO-DIESEL CONVERSION PLANT

被引:0
|
作者
Jarkoni, Mohammad Nor Khasbi [1 ]
Mansor, Wan Nurdiyana Wan [1 ]
Abd Kadir, Nurul Huda [2 ]
Ramli, Aima [2 ]
Abdullah, Samsuri [1 ]
Jalaludin, Juliana [3 ]
Hashim, Fahimah [1 ]
Yusof, Mohamad Adan [4 ]
Saad, Mohd Faisol [5 ]
Lin, Sheng-Lun [6 ]
Chao, How -Ran [7 ]
机构
[1] Univ Malaysia Terengganu, Fac Ocean Engn Technol & Informat, Kuala Nerus 21030, Terengganu, Malaysia
[2] Univ Malaysia Terengganu, Fac Sci & Marine Environm, Kuala Nerus 21030, Terengganu, Malaysia
[3] Univ Putra Malaysia, Fac Med & Hlth Sci, Serdang 43400, Selangor, Malaysia
[4] Syngas Sdn Bhd, Kuala Nerus 21300, Terengganu, Malaysia
[5] Politekn Ungku Omar, Marine Engn Dept, Jalan Raja Musa Mahadi, Ipoh 31400, Perak, Malaysia
[6] Beijing Inst Technol, Sch Mech Engn, Beijing 100081, Peoples R China
[7] Natl Pingtung Univ Sci & Technol, Coll Engn, Dept Environm Sci & Engn, Neipu 912, Pingtung, Taiwan
来源
JOURNAL OF ENGINEERING SCIENCE AND TECHNOLOGY | 2023年 / 18卷 / 05期
关键词
Air Quality; Catalytic Fractional Depolymerization; Green Diesel; Plastic-to-Diesel; Pyrolysis; WASTE; MICROPLASTICS; PYROLYSIS; ENVIRONMENT; DEPOSITION;
D O I
暂无
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The catalytic fractional depolymerization process converts plastic waste into fuel is gaining popularity since it uses non-biodegradable materials and practises proper waste management disposal methods. The purpose of this study is to investigate the trend and correlation of emissions from the plastic-to-fuel (PTF) reactor at baseline and testing mode. The plant converts Low-Density Polyethylene (LDPE) plastic wastes using PTF reactor into plastic-derived diesel fuel. The emissions of particulate matter with diameter aerodynamic less than 10 mu m (PM10), particle matter with diameter aerodynamic less than 2.5 mu m (PM2.5), carbon monoxide (CO), carbon dioxide (CO2), and volatile organic compounds (VOC) while physical factors were also investigated including air movement (AM), relative humidity (RH), and temperature (T). Eight sampling points were identified to quantify the emissions according to the standard around the PTF reactor for 3 hours for each baseline and testing mode. The findings show the emissions are higher at several points specifically near the chimney from the PTF reactor. The majority of the gases emitted did not exceed the limits according to the Industry Code of Practice on Indoor Air Quality 2010 (ICOP IAQ 2010). PM10 and PM2.5 have a strong correlation (r = 0.921) during baseline mode, followed by CO and CO2 (r = 0.908). Only PM10 and PM2.5 recorded the highest correlation during testing mode (r = 0.987). The rest show a moderate and weak correlation in both reactor conditions. There was less contamination arising during the LDPE pyrolysis process thus proving the workplace is in a safe working environment.
引用
收藏
页码:2371 / 2387
页数:17
相关论文
共 50 条
  • [21] Indoor air humidity, air quality, and health - An overview
    Wolkoff, Peder
    INTERNATIONAL JOURNAL OF HYGIENE AND ENVIRONMENTAL HEALTH, 2018, 221 (03) : 376 - 390
  • [22] Plant Design for the Conversion of Plastic Waste into Valuable Chemicals (Alkyl Aromatics)
    Alali, Sabah A. S.
    Aldaihani, Meshal K. M. B. J.
    Alanezi, Khaled M.
    APPLIED SCIENCES-BASEL, 2023, 13 (16):
  • [23] Indoor and outdoor air contaminants coupling relationship and measures of improving indoor air quality
    Geng, Shibin
    Xiao, Mingxing
    SUSTAINABLE ENVIRONMENT AND TRANSPORTATION, PTS 1-4, 2012, 178-181 : 711 - 717
  • [24] Indoor air quality management based on fuzzy risk assessment and its case study
    Yuan, Jing
    Chen, Zhi
    Zhong, Lexuan
    Wang, Baozhen
    SUSTAINABLE CITIES AND SOCIETY, 2019, 50
  • [25] Assessment of Indoor Air Quality for Group-Housed Macaques (Macaca spp.)
    Maaskant, Annemiek
    Janssen, Isabel
    Wouters, Inge M.
    Eerdenburg, Frank J. C. M.
    Remarque, Edmond J.
    Langermans, Jan A. M.
    Bakker, Jaco
    ANIMALS, 2022, 12 (14):
  • [26] The impacts of cooking and an assessment of indoor air quality in Colorado passive and tightly constructed homes
    Militello-Hourigan, Ryan E.
    Miller, Shelly L.
    BUILDING AND ENVIRONMENT, 2018, 144 : 573 - 582
  • [27] Characteristics and assessment of exposure to microplastics through inhalation in indoor air of hospitals
    Niari, Maryam Hazrati
    Ghobadi, Hassan
    Amani, Mojtaba
    Aslani, Mohammad Reza
    Fazlzadeh, Mehdi
    Matin, Somaieh
    Takaldani, Ali Hossein Samadi
    Hosseininia, Saeed
    AIR QUALITY ATMOSPHERE AND HEALTH, 2025, 18 (01): : 253 - 262
  • [28] Indoor air quality in Virginia waterpipe cafes
    Cobb, Caroline Oates
    Vansickel, Andrea Rae
    Blank, Melissa D.
    Jentink, Kade
    Travers, Mark J.
    Eissenberg, Thomas
    TOBACCO CONTROL, 2013, 22 (05) : 338 - 343
  • [29] Microbiological indoor air quality in healthy buildings
    Sessa, R
    Di Pietro, M
    Schiavoni, G
    Santino, I
    Altieri, A
    Pinelli, S
    Del Piano, M
    MICROBIOLOGICA, 2002, 25 (01): : 51 - 56
  • [30] The effects of indoor air quality on performance and productivity
    Wyon, DP
    INDOOR AIR, 2004, 14 : 92 - 101