INDOOR AIR QUALITY ASSESSMENT AT A PLASTIC-TO-DIESEL CONVERSION PLANT

被引:0
|
作者
Jarkoni, Mohammad Nor Khasbi [1 ]
Mansor, Wan Nurdiyana Wan [1 ]
Abd Kadir, Nurul Huda [2 ]
Ramli, Aima [2 ]
Abdullah, Samsuri [1 ]
Jalaludin, Juliana [3 ]
Hashim, Fahimah [1 ]
Yusof, Mohamad Adan [4 ]
Saad, Mohd Faisol [5 ]
Lin, Sheng-Lun [6 ]
Chao, How -Ran [7 ]
机构
[1] Univ Malaysia Terengganu, Fac Ocean Engn Technol & Informat, Kuala Nerus 21030, Terengganu, Malaysia
[2] Univ Malaysia Terengganu, Fac Sci & Marine Environm, Kuala Nerus 21030, Terengganu, Malaysia
[3] Univ Putra Malaysia, Fac Med & Hlth Sci, Serdang 43400, Selangor, Malaysia
[4] Syngas Sdn Bhd, Kuala Nerus 21300, Terengganu, Malaysia
[5] Politekn Ungku Omar, Marine Engn Dept, Jalan Raja Musa Mahadi, Ipoh 31400, Perak, Malaysia
[6] Beijing Inst Technol, Sch Mech Engn, Beijing 100081, Peoples R China
[7] Natl Pingtung Univ Sci & Technol, Coll Engn, Dept Environm Sci & Engn, Neipu 912, Pingtung, Taiwan
来源
JOURNAL OF ENGINEERING SCIENCE AND TECHNOLOGY | 2023年 / 18卷 / 05期
关键词
Air Quality; Catalytic Fractional Depolymerization; Green Diesel; Plastic-to-Diesel; Pyrolysis; WASTE; MICROPLASTICS; PYROLYSIS; ENVIRONMENT; DEPOSITION;
D O I
暂无
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The catalytic fractional depolymerization process converts plastic waste into fuel is gaining popularity since it uses non-biodegradable materials and practises proper waste management disposal methods. The purpose of this study is to investigate the trend and correlation of emissions from the plastic-to-fuel (PTF) reactor at baseline and testing mode. The plant converts Low-Density Polyethylene (LDPE) plastic wastes using PTF reactor into plastic-derived diesel fuel. The emissions of particulate matter with diameter aerodynamic less than 10 mu m (PM10), particle matter with diameter aerodynamic less than 2.5 mu m (PM2.5), carbon monoxide (CO), carbon dioxide (CO2), and volatile organic compounds (VOC) while physical factors were also investigated including air movement (AM), relative humidity (RH), and temperature (T). Eight sampling points were identified to quantify the emissions according to the standard around the PTF reactor for 3 hours for each baseline and testing mode. The findings show the emissions are higher at several points specifically near the chimney from the PTF reactor. The majority of the gases emitted did not exceed the limits according to the Industry Code of Practice on Indoor Air Quality 2010 (ICOP IAQ 2010). PM10 and PM2.5 have a strong correlation (r = 0.921) during baseline mode, followed by CO and CO2 (r = 0.908). Only PM10 and PM2.5 recorded the highest correlation during testing mode (r = 0.987). The rest show a moderate and weak correlation in both reactor conditions. There was less contamination arising during the LDPE pyrolysis process thus proving the workplace is in a safe working environment.
引用
收藏
页码:2371 / 2387
页数:17
相关论文
共 50 条
  • [1] Determination of indoor air quality of a phytosanitary plant
    Sanjuan-Herraez, Daniel
    Rodriguez-Carrasco, Yelko
    Juan-Peiro, Luis
    Pastor, Agustin
    de la Guardia, Miguel
    ANALYTICA CHIMICA ACTA, 2011, 694 (1-2) : 67 - 74
  • [2] Assessment of the air quality in indoor car parks
    Wong, YC
    Sin, DWM
    Yeung, LL
    INDOOR AND BUILT ENVIRONMENT, 2002, 11 (03) : 134 - 145
  • [3] Indoor Air Quality Assessment in Grocery Stores
    Baptista, Teresa
    Almeida-Silva, Marina
    Silva, Dario
    Diogo, Carlos
    Canha, Nuno
    APPLIED SCIENCES-BASEL, 2022, 12 (24):
  • [4] The use of indoor plant as an alternative strategy to improve indoor air quality in Indonesia
    Susanto, Agus Dwi
    Winardi, Wira
    Hidayat, Moulid
    Wirawan, Aditya
    REVIEWS ON ENVIRONMENTAL HEALTH, 2021, 36 (01) : 95 - 99
  • [5] Air quality assessment in indoor and outdoor environments: A review
    Prabhakaran, J.
    Jayabal, S.
    Kumar, A. Ramesh
    Vinoth, V.
    MATERIALS TODAY-PROCEEDINGS, 2022, 66 : 1260 - 1266
  • [6] Indoor-Outdoor Air Quality Assessment in Nurseries
    Abu Mansor, Amalina
    Hisham, Ain Natasha Badrul
    Abdullah, Samsuri
    Napi, Nur Nazmi Liyana Mohd
    Ahmed, Ali Najah
    Ismail, Marzuki
    2ND INTERNATIONAL CONFERENCE ON GREEN ENVIRONMENTAL ENGINEERING AND TECHNOLOGY, 2020, 616
  • [7] An assessment of the impacts of diesel power plants on air quality in Antarctica
    Sergey KAKAREKA
    Sviatlana SALIVONCHYK
    AdvancesinPolarScience, 2020, 31 (01) : 74 - 87
  • [8] Assessment of indoor air quality using different air-condition for cooling
    Wang, Wei
    Yu, Zhuang
    Zhang, Hui
    Wang, Haitao
    ADVANCES IN ENVIRONMENTAL SCIENCE AND ENGINEERING, PTS 1-6, 2012, 518-523 : 910 - +
  • [9] ASSESSMENT OF AIR QUALITY WITH INDOOR AND OUTDOOR CONDITIONS IN WUHAN, CHINA
    Ye, Xiaojiang
    Chen, Huanxin
    Zhou, Zhaoxia
    Li, Duanyong
    Hou, Zhijian
    Lu, Liangyan
    Zhou, Wei
    Qing, E.
    FIFTH INTERNATIONAL WORKSHOP ON ENERGY AND ENVIRONMENT OF RESIDENTIAL BUILDINGS AND THIRD INTERNATIONAL CONFERENCE ON BUILT ENVIRONMENT AND PUBLIC HEALTH, VOL I AND II, PROCEEDINGS, 2009, : 937 - 943
  • [10] Inhalable microplastics and plastic additives in the indoor air of chemical laboratories
    Rindelaub, Joel D.
    Miskelly, Gordon M.
    JOURNAL OF EXPOSURE SCIENCE AND ENVIRONMENTAL EPIDEMIOLOGY, 2025,