Hemodynamic investigation of a novel rotary displacement blood pump for extracorporeal membrane oxygenation

被引:0
作者
Xue, Qingxin [1 ]
Ren, Xiaoyu [1 ]
Gao, Bin [1 ]
Li, Shu [2 ]
Song, Zhiming [3 ]
Ding, Jinli [4 ]
Chang, Yu [5 ]
机构
[1] Beijing Univ Technol, Fac Environm & Life, Beijing 100124, Peoples R China
[2] Inst Med Device Control, Natl Inst Food & Drug Control, Beijing, Peoples R China
[3] Tongji Univ, Shanghai East Hosp, Dept Cardiac Surg, Sch Med, Shanghai, Peoples R China
[4] Capital Med Univ, Beijing Tiantan Hosp, Dept Radiol, Beijing, Peoples R China
[5] Zhejiang Univ, Natl Clin Res Ctr Child Hlth, Sch Med, Childrens Hosp, Hangzhou, Peoples R China
基金
中国国家自然科学基金;
关键词
blood pump; CFD; ECMO; hemodynamics; rotary displacement blood pump; FLUID-DYNAMICS ANALYSIS; SHEAR-STRESS; PERFORMANCE; DAMAGE; FLOW; HEMOLYSIS; DESIGN; HEART;
D O I
10.1002/cnm.3705
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Extracorporeal membrane oxygenation (ECMO) is a life support system used in the treatment of severe respiratory and circulatory failure. High shear stress caused by the high rotational speed of centrifugal blood pumps can cause hemolysis and platelet activation, which are among the major factors leading to the complications of the ECMO system. In this study, a novel blood pump named rotary displacement blood pump (RDBP), which can considerably reduce rotational speed and shear stress while ensuring the normal pressure flow relationship, was proposed. We employed computational fluid dynamics (CFD) analysis to investigate the performance of RDBP under adult ECMO support operating conditions (5 L/min with 350 mmHg). The efficiency and H-Q curves of the RDBP were calculated to evaluate its hydraulic performance, and pressure, flow patterns, and shear stress distribution were analyzed to estimate the hemodynamic characteristics in the pump. In addition, the modified index of hemolysis (MIH) was calculated for the RDBP based on a Eulerian approach. The hydraulic efficiency of the RDBP was 47.28%. The velocity distribution of flow field in the pump was relatively uniform. Most of the liquid (more than 75%) in the pump was exposed to low scale shear stress (<1 Pa), which was close to normal physiological conditions. The gap area was the main distribution location of high scale shear stress. The high wall shear stress (>9 Pa) volume fraction of the RDBP was small and located in the boundary areas between the rotor's edge and the housing. The MIH value of the RDBP was 9.87 +/- 0.93 (mean +/- SD). The RDBP can achieve better hydraulic efficiency and hemodynamic performance at lower rotational speed. The design of this novel pump is expected to provide a new direction for developing a blood pump for ECMO.
引用
收藏
页数:17
相关论文
共 46 条
  • [1] ECMO circuit embolism: A potentially hazardous complication during ECMO therapy
    Aizawa, Mariko
    Ishihara, Satoshi
    Yokoyama, Takeshi
    [J]. JOURNAL OF CLINICAL ANESTHESIA, 2019, 54 : 162 - 163
  • [2] Assessment of hemolysis related quantities in a microaxial blood pump by computational fluid dynamics
    Apel, J
    Paul, R
    Klaus, S
    Siess, T
    Reul, H
    [J]. ARTIFICIAL ORGANS, 2001, 25 (05) : 341 - 347
  • [3] A Novel ECMO Circuit Using a SYNERGY Circulite Pump in a Swine Model
    Biscotti, Mauer
    Singh, Gopal
    Downey, Peter
    Bacchetta, Matthew
    [J]. ASAIO JOURNAL, 2014, 60 (05) : 519 - 523
  • [4] 3-DIMENSIONAL NUMERICAL PREDICTION OF STRESS LOADING OF BLOOD PARTICLES IN A CENTRIFUGAL PUMP
    BLUDSZUWEIT, C
    [J]. ARTIFICIAL ORGANS, 1995, 19 (07) : 590 - 596
  • [5] Thrombotic Risk of Rotor Speed Modulation Regimes of Contemporary Centrifugal Continuous-flow Left Ventricular Assist Devices
    Boraschi, Andrea
    Bozzi, Silvia
    Thamsen, Bente
    Granegger, Marcus
    Wiegmann, Lena
    Pappalardo, Federico
    Slepian, Marvin J.
    Kurtcuoglu, Vartan
    Redaelli, Alberto
    De Zelicourt, Diane
    Consolo, Filippo
    [J]. ASAIO JOURNAL, 2021, 67 (07) : 737 - 745
  • [6] Numerical study of a new ventricular assist device
    Bounouib, Mohamed
    Benakrach, Hind
    Es-Sadek Zeriab, Mohamed
    Taha-Janan, Mourad
    Maazouzi, Wajih
    [J]. ARTIFICIAL ORGANS, 2020, 44 (06) : 604 - 610
  • [7] Chang M., 2015, NUMERICAL STUDY MECH
  • [8] Durability improvement of polymer chamber of pulsatile extracorporeal life support system in terms of mechanical change
    Choi, Hyuk
    Paik, Seung Hoon
    Lee, Kwang Ho
    Min, Byoung Goo
    Won, Yong Soon
    [J]. MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2007, 45 (11) : 1127 - 1135
  • [9] Effect of pump type on outcomes in neonates with congenital diaphragmatic hernia requiring ECMO
    Delaplain, Patrick T.
    Zhang, Lishi
    Nguyen, Danh V.
    Ashrafi, Amir H.
    Yu, Peter T.
    Di Nardo, Matteo
    Chen, Yanjun
    Starr, Joanne
    Ford, Henri R.
    Guner, Yigit S.
    [J]. PERFUSION-UK, 2018, 33 : 71 - 79
  • [10] An Original Versatile Nonocclusive Pressure-Regulated Blood Roller Pump for Extracorporeal Perfusion
    Durandy, Yves
    Wang, Shigang
    Uendar, Akif
    [J]. ARTIFICIAL ORGANS, 2014, 38 (06) : 469 - 473