Residual Mechanical Properties of Corroded Steel Bars after High-Temperature Exposure

被引:1
作者
Ba, Guangzhong [1 ]
Liu, Hao [2 ]
Zhang, Shaogang [1 ]
Wang, Jinhui [1 ]
机构
[1] Shanghai Maritime Univ, Coll Ocean Sci & Engn, Shanghai 201306, Peoples R China
[2] Beijing Univ Technol, Key Lab Urban Secur & Disaster Engn, Minist Educ, Beijing 100124, Peoples R China
基金
中国国家自然科学基金;
关键词
Residual mechanical properties; Steel bar; Corrosion; High temperature; Three-dimensional (3D) optical measurement; FIRE PERFORMANCE; CORROSION; REINFORCEMENT; BEHAVIOR; IMPACT;
D O I
10.1061/(ASCE)MT.1943-5533.0004661
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Accidental fires in aged concrete structures can lead to combined damage from corrosion and fire. In this study, we aimed to explore the effects of corrosion and high temperature on the residual mechanical properties of hot-rolled plain and ribbed bars. The results indicated that the corroded steel bars still exhibited ductile failure after high-temperature exposure. Moreover, the combined action of high temperature and corrosion has little effect on the elastic modulus. The residual bearing capacity of the hot-rolled steel bar became smaller under the condition of temperatures above 600 degrees C. When the temperatures experienced by the plain and ribbed steel bars were less than 600 degrees C and 500 degrees C, respectively, the high temperature accelerated the decrease in the nominal yield and ultimate strength. However, the yield and ultimate strengths based on the minimum cross-sectional area remained unchanged with an increase in the cross-sectional loss ratio. Similar to that at room temperature, the ultimate strain of steel bars subjected to high-temperature exposure decreased exponentially with an increase in the cross-sectional loss ratio. The new findings of this study can provide a theoretical basis for the safety assessment of aged reinforced concrete structures after exposure to fire.
引用
收藏
页数:12
相关论文
共 30 条
[1]  
[Anonymous], 2011, Standard Practice for Preparing, Cleaning, and Evaluating Corrosion Test Specimens
[2]  
[Anonymous], 2011, ASTM E8/E8M-11.
[3]  
ASCE, 1992, Structural fire protection, ASCE committee on fire protection
[4]  
ASTM, 2019, ASTM A36/A36M-19
[5]   Influence of reinforcement corrosion on fire performance of reinforced concrete beams [J].
Ba, Guangzhong ;
Miao, Jijun ;
Zhang, Weiping ;
Liu, Jialiang .
CONSTRUCTION AND BUILDING MATERIALS, 2019, 213 :738-747
[6]  
Cairns J, 2005, ACI MATER J, V102, P256
[7]  
CEN (European Committee for Standardization), 2004, Design of concrete structuresPart 1-1: General rules and rules for buildings
[8]  
CEN (European Committee for Standardization), 2005, Eurocode 3-Design of steel structures-Part 1-8: Design of joints.
[9]   Effectiveness of impressed current technique to simulate corrosion of steel reinforcement in concrete [J].
El Maaddawy, TA ;
Soudki, KA .
JOURNAL OF MATERIALS IN CIVIL ENGINEERING, 2003, 15 (01) :41-47
[10]   Experimental evaluation of the mechanical properties of steel reinforcement at elevated temperature [J].
Elghazouli, A. Y. ;
Cashell, K. A. ;
Izzuddin, B. A. .
FIRE SAFETY JOURNAL, 2009, 44 (06) :909-919