The Use of Low-Dose Chest Computed Tomography for the Diagnosis and Monitoring of Pulmonary Infections in Patients with Hematologic Malignancies

被引:0
作者
Agadakos, Efthimios [1 ]
Zormpala, Alexandra [1 ]
Zaios, Nikolaos [2 ]
Kapsiocha, Chrysoula [1 ]
Gamaletsou, Maria N. [3 ]
Voulgarelis, Michael [3 ]
Sipsas, Nikolaos V. [3 ]
Moulopoulos, Lia Angela [2 ]
Koutoulidis, Vassilis [2 ]
机构
[1] Gen Hosp Athens Laiko, Dept Radiol, Athens 11527, Greece
[2] Natl & Kapodistrian Univ Athens, Arete Hosp, Sch Med, Dept Radiol 1, Athens 11528, Greece
[3] Natl & Kapodistrian Univ Athens, Gen Hosp Athens Laiko, Sch Med, Dept Pathophysiol, Athens 11527, Greece
关键词
low-dose chest CT; standard-dose chest CT; neutropenic patients; hematologic malignancies; radiation dose; CT noise reduction algorithms; diagnostic performance; lung abnormalities; ITERATIVE RECONSTRUCTION TECHNIQUE; FEBRILE NEUTROPENIC PATIENTS; IMAGE QUALITY; FUNGAL-INFECTIONS; RADIATION RISKS; ABDOMINAL CT; STRATEGIES; REDUCTION; CANCER; ASPERGILLOSIS;
D O I
10.3390/cancers16010186
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Simple Summary The research aims to evaluate the diagnostic performance of low-dose chest CT (LDCCT) in detecting pulmonary infections in neutropenic patients with hematologic malignancies. Driven by concerns over radiation exposure in high-risk patients undergoing standard chest CT scans (SDCCT), the research investigates whether LDCCT, with reduced radiation and noise reduction algorithms, matches SDCCT in image quality and diagnostic accuracy. Involving 164 neutropenic patients with 256 CT exams, the study scrutinizes specific radiological criteria linked to pulmonary infections. The researchers analyzed objective parameters (such as image noise and attenuation levels), subjective evaluations (image quality, noise, and artifacts), and diagnostic performance. The findings reveal a 47% reduction in radiation dose with LDCCT but a lower diagnostic performance, especially in detecting consolidation and ground glass opacities. The authors caution against relying solely on LDCCT for initial assessments in patients with hematologic malignancies, emphasizing the importance of further research to optimize diagnostic protocols.Abstract The study aimed to assess the image quality and diagnostic performance of low-dose Chest Computed Tomography (LDCCT) in detecting pulmonary infections in patients with hematologic malignancies. A total of 164 neutropenic patients underwent 256 consecutive CT examinations, comparing 149 LDCCT and 107 Standard-Dose Chest CT (SDCCT) between May 2015 and June 2019. LDCCT demonstrated a 47% reduction in radiation dose while maintaining acceptable image noise and quality compared to SDCCT. However, LDCCT exhibited lower sensitivity in detecting consolidation (27.5%) and ground glass opacity (64.4%) compared to SDCCT (45.8% and 82.2%, respectively) with all the respective p-values from unadjusted and adjusted for sex, age, and BMI analyses being lower than 0.006 and the corresponding Odds Ratios of detection ranging from 0.30 to 0.34. Similar trends were observed for nodules >= 3 mm and ground glass halo in nodules but were not affected by sex, age and BMI. No significant differences were found for cavitation in nodules, diffuse interlobular septal thickening, pleural effusion, pericardial effusion, and lymphadenopathy. In conclusion, LDCCT achieved substantial dose reduction with satisfactory image quality but showed limitations in detecting specific radiologic findings associated with pulmonary infections in neutropenic patients compared to SDCCT.
引用
收藏
页数:16
相关论文
共 47 条
[1]  
[Anonymous], 2021, Health at a glance 2021: OECD indicators highlights for Germany
[2]  
[Anonymous], 2007, The Recommendations of the International Commission on Radiological Protection, V103, DOI DOI 10.1016/J.ICRP.2007.10.003
[3]  
[Anonymous], 1999, EN 16262
[4]   Low-dose CT of the lung: potential value of iterative reconstructions [J].
Baumueller, Stephan ;
Winklehner, Anna ;
Karlo, Christoph ;
Goetti, Robert ;
Flohr, Thomas ;
Russi, Erich W. ;
Frauenfelder, Thomas ;
Alkadhi, Hatem .
EUROPEAN RADIOLOGY, 2012, 22 (12) :2597-2606
[5]   Multi-detector row CT attenuation measurements: Assessment of intra- and interscanner variability with an anthropomorphic body CT phantom [J].
Birnbaum, Bernard A. ;
Hindman, Nicole ;
Lee, Julie ;
Babb, James S. .
RADIOLOGY, 2007, 242 (01) :109-119
[6]   Radiation risks potentially associated with low-dose CT screening of adult smokers for lung cancer [J].
Brenner, DJ .
RADIOLOGY, 2004, 231 (02) :440-445
[7]   Increasing volume and changing characteristics of invasive pulmonary aspergillosis on sequential thoracic computed tomography scans in patients with neutropenia [J].
Caillot, D ;
Couaillier, JF ;
Bernard, A ;
Casasnovas, O ;
Denning, DW ;
Mannone, L ;
Lopez, J ;
Couillault, G ;
Piard, F ;
Vagner, O ;
Guy, H .
JOURNAL OF CLINICAL ONCOLOGY, 2001, 19 (01) :253-259
[8]   Improved management of invasive pulmonary aspergillosis in neutropenic patients using early thoracic computed tomographic scan and surgery [J].
Caillot, D ;
Casasnovas, O ;
Bernard, A ;
Couaillier, JF ;
Durand, C ;
Cuisenier, B ;
Solary, E ;
Piard, F ;
Petrella, T ;
Bonnin, A ;
Couillault, G ;
Dumas, M ;
Guy, H .
JOURNAL OF CLINICAL ONCOLOGY, 1997, 15 (01) :139-147
[9]   Delaying amphotericin B-based frontline therapy significantly increases mortality among patients with Hematologic malignancy who have zygomycosis [J].
Chamilos, Georgios ;
Lewis, Russell E. ;
Kontoyiannis, Dimitrios P. .
CLINICAL INFECTIOUS DISEASES, 2008, 47 (04) :503-509
[10]   THE ROLE OF THE CHEST ROENTGENOGRAM IN FEBRILE NEUTROPENIC PATIENTS [J].
DONOWITZ, GR ;
HARMAN, C ;
POPE, T ;
STEWART, FM .
ARCHIVES OF INTERNAL MEDICINE, 1991, 151 (04) :701-704