The use of bovine-derived hydroxyapatite xenograft for defect filling in opening-wedge high tibial osteotomy

被引:0
作者
Santoso, Asep [1 ]
Utomo, Pamudji [1 ]
Mahyudin, Ferdiansyah [2 ]
Utomo, Dwikora N. [2 ]
Budhiparama, Nicolaas C. [2 ,3 ]
Anwar, Iwan B. [1 ]
Sibarani, Tangkas [1 ]
Warman, Fanny I. [1 ]
机构
[1] Sebelas Maret Univ, Dept Orthopaed & Traumatol, Prof Dr R Soeharso Orthopaed Hosp, Surakarta, Indonesia
[2] Airlangga Univ, Dr Soetomo Gen Hosp, Dept Orthopaed & Traumatol, Surabaya, Indonesia
[3] Medistra Hosp, Nicolaas Inst Construct Orthopaed Res & Educ Fdn A, Jakarta, Indonesia
关键词
calcium hydroxyapatite; knee joint; osteotomy; xenograft; BONE-GRAFT; ALLOGRAFT; UNION; PLATE; SUBSTITUTE; OUTCOMES;
D O I
10.1097/MS9.0000000000000972
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction:High tibial osteotomy is a reliable procedure for the correction of knee varus deformity. An opening-wedge high tibial osteotomy (OW-HTO) is the most popular technique. The results of the bone defect after opening the wedge needed special treatment to ensure bone healing. This study aims to evaluate the use of bovine-derived hydroxyapatite graft for defect filling after OW-HTO.Methods:A retrospective study was performed on all patients who received OW-HTO at Prof. Dr R. Soeharso Orthopaedic Hospital from November 2019 to December 2022. A total of 21 patients (24 knees) were included in this study. Clinical dan radiological evaluation was performed on all patients preoperative and postoperatively. The mean of the follow-up period was 12.6 months with a minimum of 4 months follow-up.Results:Primary medial uni-compartment knee osteoarthritis was the most common diagnosis, with 17 of 24 cases (70.8%). Mechanical axis deviation was changed from 31 mm medial deviation (range: 8-52 mm) to 0.45 mm medial deviation (range: 13 - (-8) mm). The anatomic tibiofemoral angle was corrected from a preoperative mean of 4.7 degrees of varus to a mean of 5.8 degrees of valgus postoperatively. Bone defect height was mean 15.9 mm with a range of 10-23 mm. Bone defect width was mean 46.7 mm (range: 34-60 mm). Hydroxyapatite graft integration with the host bone was found in all patients during the final follow-up period.Conclusions:Bovine-derived hydroxyapatite graft is a safe and effective material for bone defect filling in OW-HTO procedures with a high bone union rate.
引用
收藏
页码:3339 / 3346
页数:8
相关论文
共 22 条
[1]   STROCSS 2019 Guideline: Strengthening the reporting of cohort studies in surgery [J].
Agha, Riaz ;
Abdall-Razak, Ali ;
Crossley, Eleanor ;
Dowlut, Naeem ;
Iosifidis, Christos ;
Mathew, Ginimol ;
Beamishaj ;
Bashashati, Mohammad ;
Millham, Frederick H. ;
Orgill, Dennis P. ;
Noureldin, Ashraf ;
James, Iain ;
Alsawadi, Abdulrahman ;
Bradley, Patrick J. ;
Giordano, Salvatore ;
Laskin, Daniel M. ;
Basu, Somprakas ;
Johnston, Maximilian ;
Muensterer, Oliver J. ;
Mukherjee, Indraneil ;
Chi-Yong, James Ngu ;
Valmasoni, Michele ;
Pagano, Duilio ;
Vasudevan, Baskaran ;
Rosin, Richard David ;
McCaul, James Anthony ;
Albrecht, Jorg ;
Hoffman, Jerome R. ;
Thorat, Mangesh A. ;
Massarut, Samuele ;
Thoma, Achilles ;
Kirshtein, Boris ;
Afifi, Raafat Yahia ;
Farooq, Naheed ;
Challacombe, Ben ;
Pai, Prathamesh S. ;
Perakath, Benjamin ;
Kadioglu, Huseyin ;
Aronson, Jeffrey K. ;
Raveendran, Kandiah ;
Machado-Aranda, David ;
Klappenbach, Roberto ;
Healy, Donagh ;
Miguel, Diana ;
Leles, Claudio Rodrigues ;
Ather, M. Hammad .
INTERNATIONAL JOURNAL OF SURGERY, 2019, 72 :156-165
[2]  
Athanasiou VT, 2010, MED SCI MONITOR, V16, pBR24
[3]   Graft materials provide greater static strength to medial opening wedge high tibial osteotomy than when no graft is included [J].
Belsey, James ;
Kaze, Arnaud Diffo ;
Jobson, Simon ;
Faulkner, James ;
Maas, Stefan ;
Khakha, Raghbir ;
Wilson, Adrian J. ;
Pape, Dietrich .
JOURNAL OF EXPERIMENTAL ORTHOPAEDICS, 2019, 6 (01)
[4]   Opening wedge high tibial osteotomy performed without filling the defect but with locking plate fixation (TomoFix™) and early weight-bearing: Prospective evaluation of bone union, precision and maintenance of correction in 51 cases [J].
Brosset, T. ;
Pasquier, G. ;
Migaud, H. ;
Gougeon, F. .
ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2011, 97 (07) :705-711
[5]  
Cho Sung Won, 2013, Knee Surg Relat Res, V25, P117, DOI 10.5792/ksrr.2013.25.3.117
[6]   Mid-term CT assessment of bone healing after nanohydroxyapatite augmentation in open-wedge high tibial osteotomy [J].
Drogo, Piergiorgio ;
Andreozzi, Valerio ;
Rossini, Marco ;
Caperna, Ludovico ;
Iorio, Raffaele ;
Mazza, Daniele ;
Ferretti, Andrea ;
Conteduca, Fabio .
KNEE, 2020, 27 (04) :1167-1175
[7]  
Han Jae Hwi, 2015, Knee Surg Relat Res, V27, P207, DOI [10.5792/ksrr.2015.27.4.207, 10.5792/ksrr.2015.27.4.207]
[8]   Progress in the treatment of knee osteoarthritis with high tibial osteotomy: a systematic review [J].
He, Mingliang ;
Zhong, Xihong ;
Li, Zhong ;
Shen, Kun ;
Zeng, Wen .
SYSTEMATIC REVIEWS, 2021, 10 (01)
[9]  
Hooper N M, 2013, Open Orthop J, V7, P373, DOI 10.2174/1874325001307010373
[10]   Survival and Risk Factor Analysis of Medial Open Wedge High Tibial Osteotomy for Unicompartment Knee Ostzoarthritis [J].
Jin, Cheng ;
Song, Eun-Kyoo ;
Santoso, Asep ;
Ingale, Pramod Shaligram ;
Choi, Ik-Sun ;
Seon, Jong-Keun .
ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2020, 36 (02) :535-543