Metal artifacts reduction in kV-CT images with polymetallic dentures and complex metals based on MV-CBCT images in radiotherapy

被引:3
作者
Ni, Xiaochen [1 ]
Shi, Zhonghua [2 ]
Song, Xinmao [1 ]
Tang, Tianci [1 ]
Li, Shengwei [1 ]
Hou, Zhenfeng [2 ]
Zhang, Wei [2 ]
Wang, Wei Fang [1 ]
Chen, Fu [1 ]
Li, Ji [1 ]
Yang, Gang [1 ]
Li, Ruichen [1 ]
Wang, Xiaoshen [1 ,3 ]
机构
[1] Fudan Univ, Eye & ENT Hosp, Dept Radiotherapy, 83 Fenyang Rd, Shanghai 200031, Peoples R China
[2] Shanghai United Imaging Healthcare Co Ltd, Shanghai 201800, Peoples R China
[3] Fudan Univ, Jiangyue Rd 2600, Shanghai, Peoples R China
关键词
RECONSTRUCTION; NECK; NMAR;
D O I
10.1038/s41598-023-35736-x
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
This paper proposes a metal artifact reduction method of using MV-CBCT images to correct metal artifacts in kV-CT images, especially for the complex metal artifacts caused by multi-metal interaction of patients with head and neck tumors. The different tissue regions are segmented in the MV-CBCT images to obtain template images and the metal region is segmented in the kV-CT images. Forward projection is performed to get sinogram of the template images, kV-CT images and metal region images. Artifact images can be reconstructed through those sonograms. Corrected images is generated by subtracting the artifact images from the original kV-CT images. After the first correction, the template images are generated again and brought into the previous step for iteration to get better correction result. CT data set of 7 patients are used in this study, compared with linear interpolation metal artifact (LIMAR) and normalized metal artifact reduction method, mean relative error of CT value is reduced by 50.5% and 63.3%, noise is reduced by 56.2% and 58.9%. The Identifiability Score of the tooth, upper/lower jaw, tongue, lips, masseter muscle and cavity in the corrected images by the proposed method have significantly improved (P < 0.05) than original images. The artifacts correction method proposed in this paper can effectively remove the metal artifacts in the images and greatly improve the CT value accuracy, especially in the case of multi-metal and complex metal implantation.
引用
收藏
页数:12
相关论文
共 33 条
  • [1] Assessment of metal artifact reduction methods in pelvic CT
    Abdoli, Mehrsima
    Mehranian, Abolfazl
    Ailianou, Angeliki
    Becker, Minerva
    Zaidi, Habib
    [J]. MEDICAL PHYSICS, 2016, 43 (04) : 1588 - 1597
  • [2] Model-Based Iterative Reconstruction (MBIR) for the Reduction of Metal Artifacts on CT
    Boudabbous, Sana
    Arditi, Daniel
    Paulin, Emilie
    Syrogiannopoulou, Aphrodite
    Becker, Christoph
    Montet, Xavier
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2015, 205 (02) : 380 - 385
  • [3] Dong Y., 2018, ACTA RADIOL, V59, P853, DOI [10.1177/0284185117731475, DOI 10.1177/0284185117731475]
  • [4] Gao Liugang, 2017, Sheng Wu Yi Xue Gong Cheng Xue Za Zhi, V34, P730, DOI 10.7507/1001-5515.201609071
  • [5] Metal artifact reduction through MVCBCT and kVCT in radiotherapy
    Gao Liugang
    Sun Hongfei
    Ni Xinye
    Fang Mingming
    Cao Zheng
    Lin Tao
    [J]. SCIENTIFIC REPORTS, 2016, 6
  • [6] Hseih J, 2009, COMPUT TOMOGR
  • [7] Metal artifact reduction on cervical CT images by deep residual learning
    Huang, Xia
    Wang, Jian
    Tang, Fan
    Zhong, Tao
    Zhang, Yu
    [J]. BIOMEDICAL ENGINEERING ONLINE, 2018, 17
  • [8] Generation of hybrid sinograms for the recovery of kV-CT images with metal artifacts for helical tomotherapy
    Jeon, Hosang
    Park, Dahl
    Youn, Hanbean
    Nam, Jiho
    Lee, Jayoung
    Kim, Wontaek
    Ki, Yongkan
    Kim, Yong Ho
    Lee, Ju Hye
    Kim, Dongwon
    Kim, Ho Kyung
    [J]. MEDICAL PHYSICS, 2015, 42 (08) : 4654 - 4667
  • [9] REDUCTION OF CT ARTIFACTS CAUSED BY METALLIC IMPLANTS
    KALENDER, WA
    HEBEL, R
    EBERSBERGER, J
    [J]. RADIOLOGY, 1987, 164 (02) : 576 - 577
  • [10] Kano Toru, 2015, Transactions of the Society of Instrument and Control Engineers, V51, P836