Fault protection scheme of flexible DC grid based on transient power instantaneous energy difference

被引:0
|
作者
Wei, Yan-fang [1 ,2 ]
Hu, Ming-hui [1 ]
Wang, Peng [3 ]
Zeng, Zhi-hui [1 ]
Wang, Xiao-wei [4 ]
机构
[1] Henan Polytech Univ, Sch Elect Engn & Automat, Jiaozuo 454003, Peoples R China
[2] Henan Polytech Univ, Henan Key Lab Intelligent Detect & Control Coal Mi, Jiaozuo 454003, Peoples R China
[3] State Grid Henan Elect Power Co, Sci Res Inst, Zhengzhou 450052, Peoples R China
[4] Xian Univ Technol, Sch Elect Engn, Xian 710000, Peoples R China
基金
中国国家自然科学基金;
关键词
Flexible DC grid; Fault analysis; Teager energy operator; Transient power; IE differences;
D O I
10.1016/j.epsr.2023.109453
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The DC line protection is the key to the stable operation of the multi-terminal flexible DC grid, and the current limiting reactor (CLR) as the boundary condition provides great convenience for the design of the flexible DC grid fault protection scheme. Using the boundary condition characteristics of the CLR, the paper proposes a fault protection method for flexible DC grid based on transient power instantaneous energy (IE) difference. First, the equivalent circuit of the DC line of the flexible DC grid under different faults is established. On this basis, the conclusion that the transient power amplitude of internal fault is much larger than the external is deduced from the full-power in the time-domain. The Teager energy operator is used to calculate the maximum IE of the transient power, and then the internal and external faults are identified. Secondly, according to the difference of the transient power amplitude of the CLR on the fault pole and the healthy pole, the ratio of the IE of the positive and negative CLR transient power is used to construct the fault pole selection. The scheme is simple and easy to implement, and does not need to consider the synchronization problem of data at both sides. Finally, the simulation results show that the proposed method can better satisfy the speediness and selectivity requirements of DC grid protection. The scheme can accurately detect faults under different working conditions, and has strong fault resistances capability.
引用
收藏
页数:12
相关论文
共 50 条
  • [41] Longitudinal Protection Based on Phase Trajectory of Fault Component Instantaneous Power
    Liu, Shiming
    Zhang, Yuhao
    Wu, Jukun
    Zhu, Xisong
    Zhao, Guochao
    2019 IEEE 13TH INTERNATIONAL CONFERENCE ON COMPATIBILITY, POWER ELECTRONICS AND POWER ENGINEERING (CPE-POWERENG), 2019,
  • [42] A coupling voltage based adaptive reclosing scheme for flexible DC grid
    Wei, Xiuyan
    Zou, Guibin
    Zhang, Shuo
    Zhang, Chengquan
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2023, 17 (05) : 1007 - 1020
  • [43] DC Line Protection for Flexible MVDC Distribution Grid With Renewable Energy Resources
    Dai, Zhihui
    Zhu, Huijun
    Su, Huaibo
    Huang, Min
    Ma, Mingzhu
    2018 IEEE POWER & ENERGY SOCIETY GENERAL MEETING (PESGM), 2018,
  • [44] Frequency Domain Impedance Based Protection for Flexible DC Distribution Grid
    Wei, Xiuyan
    Zou, Guibin
    Zhang, Shuo
    Xu, Chunhua
    IEEE ACCESS, 2022, 10 : 114203 - 114213
  • [45] Frequency Domain Impedance Based Protection for Flexible DC Distribution Grid
    Wei, Xiuyan
    Zou, Guibin
    Zhang, Shuo
    Xu, Chunhua
    IEEE Access, 2022, 10 : 114203 - 114213
  • [46] Pilot Protection Method of Flexible DC Grid Based on Linear Regression
    Shu H.
    Dai Y.
    An N.
    Tang Y.
    Bo Z.
    Diangong Jishu Xuebao/Transactions of China Electrotechnical Society, 2022, 37 (13): : 3213 - 3288
  • [47] Research on DC Grid protection scheme based on hybrid circuit breaker
    Jin T.
    Su J.-S.
    Zhang M.-Y.
    Dianji yu Kongzhi Xuebao/Electric Machines and Control, 2020, 24 (03): : 106 - 113
  • [48] A flexible DC distribution network line unipolar grounding protection method based on transient power direction
    Li, Weifeng
    Wang, Chao
    Xue, Yongduan
    Li, Juan
    Xu, Bingyin
    Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control, 2021, 49 (23): : 1 - 10
  • [49] Instantaneous Active Power Integral Differential Protection for Hybrid AC/DC Transmission Systems Based on Fault Variation Component
    Huang, Jiakai
    Gao, Houlei
    Zhao, Le
    Feng, Yuyao
    Gao, Houlei (houleig@sdu.edu.cn), 1600, Institute of Electrical and Electronics Engineers Inc. (35): : 2791 - 2799
  • [50] Instantaneous Active Power Integral Differential Protection for Hybrid AC/DC Transmission Systems Based on Fault Variation Component
    Huang, Jiakai
    Gao, Houlei
    Zhao, Le
    Feng, Yuyao
    IEEE TRANSACTIONS ON POWER DELIVERY, 2020, 35 (06) : 2791 - 2799