Seismic performance assessment and retrofitting proposal for a historic masonry school building (Bursa, Turkiye)

被引:12
作者
Cosgun, Turgay [1 ]
Ceylan, Oguz [2 ]
Nasery, Mohammad Manzoor [3 ]
Guler, Omer [4 ]
Sayin, Baris [1 ]
Uzdil, Oguz [5 ]
Akcay, Cemil [6 ]
机构
[1] Istanbul Univ Cerrahpasa, Dept Civil Engn, TR-34320 Istanbul, Turkiye
[2] Mimar Sinan Fine Arts Univ, Dept Architecture, TR-34427 Istanbul, Turkiye
[3] Dynam Muhendislik Co, TR-61010 Trabzon, Turkiye
[4] Restorasyon Co, ARJ Mimarlik, TR-16220 Bursa, Turkiye
[5] Istanbul Univ Cerrahpasa, Inst Grad Studies, TR-34320 Istanbul, Turkiye
[6] Istanbul Univ, Dept Architecture, TR-34116 Istanbul, Turkiye
关键词
Architectural heritage; Masonry building; Retrofitting proposal; Timber slab; Seismic performance analysis; HERITAGE; BEHAVIOR;
D O I
10.1016/j.cscm.2023.e02087
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The current paper presents all stages of a masonry building restoration including seismic per-formance assessment of the restored building, and a seismic retrofitting proposal accordingly. All these practices were carried out on a historical school building with timber slabs constructed in 1912. The study was composed of six stages: i. Historical research to identify all previous in-terventions in the building, ii. On-site examinations to determine the geometrical and structural properties of the building, iii. Laboratory tests to identify original material properties and determine repair materials, iv. Restoration decision and implementation of the restoration, v. Numerical analyses to assess the seismic performance of the restored building, and vi. Retrofitting proposal. The primary aim of this study is to present a comprehensive guide for seismic perfor-mance assessment and retrofitting approaches for similar buildings. The story shear forces and inter-story drifts of the examined building were obtained by linear and nonlinear analyses and compared with the limit values given in the applicable seismic code; accordingly, the seismic performance of the building was assessed. On the other hand, vertical and lateral bending collapse mechanisms were determined by local analyses. Based on the obtained findings, the building was found to have sufficient displacement capacity; however, failed in shear. Addi-tionally, we believe that the presented restoration practices and seismic performance assessment aiming the structural integrity of the historic building will contribute to the literature.
引用
收藏
页数:35
相关论文
共 49 条
  • [1] AFAD, 2019, TURK EARTHQ RISK MAP
  • [2] Seismic retrofitting of the historical masonry structures using numerical approach
    Akcay, Cemil
    Bozkurt, Tank Serhat
    Sayin, Baris
    Yildizlar, Baris
    [J]. CONSTRUCTION AND BUILDING MATERIALS, 2016, 113 : 752 - 763
  • [3] [Anonymous], 2009, C153109 ASTM ASTM IN
  • [4] [Anonymous], 2020, STAT REP BUILD
  • [5] [Anonymous], 2019, ART HIST REP BUILD
  • [6] [Anonymous], 2003, C153103 ASTM ASTM IN
  • [7] [Anonymous], 2019, REST REP BUILD
  • [8] [Anonymous], 2019, REST REP REG BUILD
  • [9] [Anonymous], 2014, 1962 TS EN TURK STAN
  • [10] [Anonymous], 2020, C67C67M20 ASTM ASTM