Feasibility of delivered dose reconstruction for MR-guided SBRT of pancreatic tumors with fast, real-time 3D cine MRI

被引:7
|
作者
Grimbergen, Guus [1 ]
Pötgens, Giulia G. [2 ]
Eijkelenkamp, Hidde [1 ]
Raaymakers, Bas W. [1 ]
Intven, Martijn P. W. [1 ]
Meijer, Gert J. [1 ]
机构
[1] Univ Med Ctr Utrecht, Dept Radiat Oncol, Utrecht, Netherlands
[2] Eindhoven Univ Technol, Dept Biomed Engn, Eindhoven, Netherlands
关键词
Pancreatic cancer; MR -guided SBRT; Intrafraction motion; Dose reconstruction; 3D cine MRI; DEFORMABLE IMAGE REGISTRATION; RESPIRATORY MOTION; RADIOTHERAPY; UNCERTAINTIES; ACCUMULATION; SYSTEM; FIELDS; HEAD; CONSISTENCY; VALIDATION;
D O I
10.1016/j.radonc.2023.109506
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background and purpose: In MR-guided SBRT of pancreatic cancer, intrafraction motion is typically monitored with (interleaved) 2D cine MRI. However, tumor surroundings are often not fully captured in these images, and motion might be distorted by through-plane movement. In this study, the feasibility of highly accelerated 3D cine MRI to reconstruct the delivered dose during MR-guided SBRT was assessed. Materials and methods: A 3D cine MRI sequence was developed for fast, time-resolved 4D imaging, featuring a low spatial resolution that allows for rapid volumetric imaging at 430 ms. The 3D cines were acquired during the entire beam-on time of 23 fractions of online adaptive MR-guided SBRT for pancreatic tumors on a 1.5 T MR-Linac. A 3D deformation vector field (DVF) was extracted for every cine dynamic using deformable image registration. Next, these DVFs were used to warp the partial dose delivered in the time interval between consecutive cine acquisitions. The warped dose plans were summed to obtain a total delivered dose. The delivered dose was also calculated under various motion correction strategies. Key DVH parameters of the GTV, duodenum, small bowel and stomach were extracted from the delivered dose and compared to the planned dose. The uncertainty of the calculated DVFs was determined with the inverse consistency error (ICE) in the high-dose regions.Results: The mean (SD) relative (ratio delivered/planned) D99% of the GTV was 0.94 (0.06), and the mean (SD) relative D0.5cc of the duodenum, small bowel, and stomach were respectively 0.98 (0.04), 1.00 (0.07), and 0.98 (0.06). In the fractions with the lowest delivered tumor coverage, it was found that significant lateral drifts had occurred. The DVFs used for dose warping had a low uncertainty with a mean (SD) ICE of 0.65 (0.07) mm.Conclusion: We employed a fast, real-time 3D cine MRI sequence for dose reconstruction in the upper abdomen, and demonstrated that accurate DVFs, acquired directly from these images, can be used for dose warping. The reconstructed delivered dose showed only a modest degradation of tumor coverage, mostly attainable to baseline drifts. This emphasizes the need for motion monitoring and development of intrafraction treatment adaptation solutions, such as baseline drift corrections.(c) 2023 The Author(s). Published by Elsevier B.V. Radiotherapy and Oncology 182 (2023) 1-7 This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).
引用
收藏
页数:7
相关论文
共 40 条
  • [31] Real-Time 3D Reconstruction of Guidewires and Stents Using Two Update X-Ray Projections in a Rotating Imaging Setup
    Voeth, Tim
    Koenig, Thomas
    Eulig, Elias
    Knaup, Michael
    Wiesmann, Veit
    Hoerndler, Klaus
    Kachelriess, Marc
    MEDICAL PHYSICS, 2023, 50 (09) : 5312 - 5330
  • [32] Real-time 2D/3D registration using kV-MV image pairs for tumor motion tracking in image guided radiotherapy
    Furtado, Hugo
    Steiner, Elisabeth
    Stock, Markus
    Georg, Dietmar
    Birkfellner, Wolfgang
    ACTA ONCOLOGICA, 2013, 52 (07) : 1464 - 1471
  • [33] Integration of free-hand 3D ultrasound and mobile C-arm cone-beam CT: Feasibility and characterization for real-time guidance of needle insertione
    Marinetto, E.
    Uneri, A.
    De Silva, T.
    Reaungamornrat, S.
    Zbijewski, W.
    Sisniega, A.
    Vogt, S.
    Kleinszig, G.
    Pascau, J.
    Siewerdsen, J. H.
    COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 2017, 58 : 13 - 22
  • [34] Real-Time Tumor Motion Tracking in 3D Using Planning 4D CT Images during Image-Guided Radiation Therapy
    Choi, Jang-Hwan
    Lee, Sooyeul
    ALGORITHMS, 2018, 11 (10):
  • [35] Real-time volumetric image reconstruction and 3D tumor localization based on a single x-ray projection image for lung cancer radiotherapy
    Li, Ruijiang
    Jia, Xun
    Lewis, John H.
    Gu, Xuejun
    Folkerts, Michael
    Men, Chunhua
    Jiang, Steve B.
    MEDICAL PHYSICS, 2010, 37 (06) : 2822 - 2826
  • [36] Real-time intensity based 2D/3D registration using kV-MV image pairs for tumor motion tracking in image guided radiotherapy
    Furtado, H.
    Steiner, E.
    Stock, M.
    Georg, D.
    Birkfellner, W.
    MEDICAL IMAGING 2014: IMAGE PROCESSING, 2014, 9034
  • [37] Ultra-fast multi-parametric 4D-MRI image reconstruction for real-time applications using a downsampling-invariant deformable registration (D2R) model
    Xiao, Haonan
    Han, Xinyang
    Zhi, Shaohua
    Wong, Yat-Lam
    Liu, Chenyang
    Li, Wen
    Liu, Weiwei
    Wang, Weihu
    Zhang, Yibao
    Wu, Hao
    Lee, Ho-Fun Victor
    Cheung, Lai-Yin Andy
    Chang, Hing-Chiu
    Liao, Yen-Peng
    Deng, Jie
    Li, Tian
    Cai, Jing
    RADIOTHERAPY AND ONCOLOGY, 2023, 189
  • [38] RT-SRTS: Angle-agnostic real-time simultaneous 3D reconstruction and tumor segmentation from single X-ray projection
    Zhu M.
    Fu Q.
    Liu B.
    Zhang M.
    Li B.
    Luo X.
    Zhou F.
    Computers in Biology and Medicine, 2024, 173
  • [39] Comparing accuracy in guided endodontics: dynamic real-time navigation, static guides, and manual approaches for access cavity preparation - an in vitro study using 3D printed teeth
    Huth, Karin Christine
    Borkowski, Lukas
    Liebermann, Anja
    Berlinghoff, Frank
    Hickel, Reinhard
    Schwendicke, Falk
    Reymus, Marcel
    CLINICAL ORAL INVESTIGATIONS, 2024, 28 (04)
  • [40] Real-Time 3D Image Guidance Using a Standard LINAC: Measured Motion, Accuracy, and Precision of the First Prospective Clinical Trial of Kilovoltage Intrafraction Monitoring-Guided Gating for Prostate Cancer Radiation Therapy
    Keall, Paul J.
    Ng, Jin Aun
    Juneja, Prabhjot
    O'Brien, Ricky T.
    Huang, Chen-Yu
    Colvill, Emma
    Caillet, Vincent
    Simpson, Emma
    Poulsen, Per R.
    Kneebone, Andrew
    Eade, Thomas
    Booth, Jeremy T.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2016, 94 (05): : 1015 - 1021