Feasibility of delivered dose reconstruction for MR-guided SBRT of pancreatic tumors with fast, real-time 3D cine MRI

被引:7
|
作者
Grimbergen, Guus [1 ]
Pötgens, Giulia G. [2 ]
Eijkelenkamp, Hidde [1 ]
Raaymakers, Bas W. [1 ]
Intven, Martijn P. W. [1 ]
Meijer, Gert J. [1 ]
机构
[1] Univ Med Ctr Utrecht, Dept Radiat Oncol, Utrecht, Netherlands
[2] Eindhoven Univ Technol, Dept Biomed Engn, Eindhoven, Netherlands
关键词
Pancreatic cancer; MR -guided SBRT; Intrafraction motion; Dose reconstruction; 3D cine MRI; DEFORMABLE IMAGE REGISTRATION; RESPIRATORY MOTION; RADIOTHERAPY; UNCERTAINTIES; ACCUMULATION; SYSTEM; FIELDS; HEAD; CONSISTENCY; VALIDATION;
D O I
10.1016/j.radonc.2023.109506
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background and purpose: In MR-guided SBRT of pancreatic cancer, intrafraction motion is typically monitored with (interleaved) 2D cine MRI. However, tumor surroundings are often not fully captured in these images, and motion might be distorted by through-plane movement. In this study, the feasibility of highly accelerated 3D cine MRI to reconstruct the delivered dose during MR-guided SBRT was assessed. Materials and methods: A 3D cine MRI sequence was developed for fast, time-resolved 4D imaging, featuring a low spatial resolution that allows for rapid volumetric imaging at 430 ms. The 3D cines were acquired during the entire beam-on time of 23 fractions of online adaptive MR-guided SBRT for pancreatic tumors on a 1.5 T MR-Linac. A 3D deformation vector field (DVF) was extracted for every cine dynamic using deformable image registration. Next, these DVFs were used to warp the partial dose delivered in the time interval between consecutive cine acquisitions. The warped dose plans were summed to obtain a total delivered dose. The delivered dose was also calculated under various motion correction strategies. Key DVH parameters of the GTV, duodenum, small bowel and stomach were extracted from the delivered dose and compared to the planned dose. The uncertainty of the calculated DVFs was determined with the inverse consistency error (ICE) in the high-dose regions.Results: The mean (SD) relative (ratio delivered/planned) D99% of the GTV was 0.94 (0.06), and the mean (SD) relative D0.5cc of the duodenum, small bowel, and stomach were respectively 0.98 (0.04), 1.00 (0.07), and 0.98 (0.06). In the fractions with the lowest delivered tumor coverage, it was found that significant lateral drifts had occurred. The DVFs used for dose warping had a low uncertainty with a mean (SD) ICE of 0.65 (0.07) mm.Conclusion: We employed a fast, real-time 3D cine MRI sequence for dose reconstruction in the upper abdomen, and demonstrated that accurate DVFs, acquired directly from these images, can be used for dose warping. The reconstructed delivered dose showed only a modest degradation of tumor coverage, mostly attainable to baseline drifts. This emphasizes the need for motion monitoring and development of intrafraction treatment adaptation solutions, such as baseline drift corrections.(c) 2023 The Author(s). Published by Elsevier B.V. Radiotherapy and Oncology 182 (2023) 1-7 This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).
引用
收藏
页数:7
相关论文
共 40 条
  • [21] Association of Internal and External Motion Based on Cine MR Images Acquired During Real-Time Treatment on MRI-Guided Linear Accelerator for Patients With Lung Cancer
    Mao, Weihua
    Kim, Joshua
    Chetty, Indrin J.
    ADVANCES IN RADIATION ONCOLOGY, 2024, 9 (01)
  • [22] A flexible 9-channel coil array for fast 3D MR thermometry in MR-guided high-intensity focused ultrasound (HIFU) studies on rabbits at 3 T
    Chen, Qiaoyan
    Li, Ye
    Jiang, Rui
    Zou, Chao
    Tie, Changjun
    Wen, Jianhong
    Yang, Xing
    Zhang, Xiaoliang
    Liu, Xin
    Zheng, Hairong
    MAGNETIC RESONANCE IMAGING, 2020, 65 : 37 - 44
  • [23] Towards real-time EPID-based 3D in vivo dosimetry for IMRT with Deep Neural Networks: A feasibility study
    Martins, Juliana Cristina
    Maier, Joscha
    Gianoli, Chiara
    Neppl, Sebastian
    Dedes, George
    Alhazmi, Abdulaziz
    Veloza, Stella
    Reiner, Michael
    Belka, Claus
    Kachelriess, Marc
    Parodi, Katia
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2023, 114
  • [24] Real-time registration of 3D to 2D ultrasound images for image-guided prostate biopsy
    Gillies, Derek J.
    Gardi, Lori
    De Silva, Tharindu
    Zhao, Shuang-ren
    Fenster, Aaron
    MEDICAL PHYSICS, 2017, 44 (09) : 4708 - 4723
  • [25] Large-Scale, Real-Time 3D Scene Reconstruction Using Visual and IMU Sensors
    Li, Changdi
    Yu, Lei
    Fei, Shumin
    IEEE SENSORS JOURNAL, 2020, 20 (10) : 5597 - 5605
  • [26] 3D printing on freeform surface: Real-time and accurate 3D dynamic dense surface reconstruction with HoloLens and displacement measurement sensors
    Sheng, Yu-Ting
    Liong, Sze-Teng
    Wang, Shih-Yuan
    Gan, Yee-Siang
    ADVANCES IN MECHANICAL ENGINEERING, 2023, 15 (01)
  • [27] Real-time 3D video-based MR remote collaboration using gesture cues and virtual replicas
    Zhang, Xiangyu
    Bai, Xiaoliang
    Zhang, Shusheng
    He, Weiping
    Wang, Peng
    Wang, Zhuo
    Yan, Yuxiang
    Yu, Quan
    INTERNATIONAL JOURNAL OF ADVANCED MANUFACTURING TECHNOLOGY, 2022, 121 (11-12) : 7697 - 7719
  • [28] 2D mapping of the MV photon fluence and 3D dose reconstruction in real time for quality assurance during radiotherapy treatment
    Alrowaili, Z. A.
    Lerch, M. L. F.
    Carolan, M.
    Fuduli, I.
    Porumb, C.
    Petasecca, M.
    Metcalfe, P.
    Rosenfeld, A. B.
    JOURNAL OF INSTRUMENTATION, 2015, 10
  • [29] SLAMCast: Large-Scale, Real-Time 3D Reconstruction and Streaming for lmmersive Multi-Client Live Telepresence
    Stotko, Patrick
    Krunnpen, Stefan
    Hullin, Matthias B.
    Weinnnann, Michael
    Klein, Reinhard
    IEEE TRANSACTIONS ON VISUALIZATION AND COMPUTER GRAPHICS, 2019, 25 (05) : 2102 - 2112
  • [30] Real-time, single breath-hold, multi-slice, 2D cine radial MR image reconstruction using sc-GROG k-t ESPIRiT
    Aslam, Ibtisam
    Crowe, Lindsey A.
    Kassai, Miklos
    Qazi, Sohaib Ayaz
    Omer, Hammad
    Vallee, Jean-Paul
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2022, 8 (06)