Influence of the postpolymerization type and time on the flexural strength and dimensional stability of 3D printed interim resins

被引:10
作者
Silva, Nathalia R. [1 ]
Moreira, Fernanda G. de G. [1 ]
Cabral, Ana B. de C. [1 ]
Bottino, Marco A. [2 ]
Marinho, Renata M. de M. [2 ]
Souza, Rodrigo O. A. [1 ,3 ]
机构
[1] Fed Univ Rio Grande Norte UFRN, Dept Dent, Natal, RN, Brazil
[2] Sao Paulo State Univ UNESP, Inst Sci & Technol, Sao Paulo, Brazil
[3] Fed Univ Rio Grande Norte UFRN, Dept Dent, Ave Salgado Filho 1787, BR-59056000 Natal, RN, Brazil
关键词
MARGINAL ADAPTATION; FIT;
D O I
10.1016/j.prosdent.2023.07.030
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. The mechanical strength of 3-dimensionally (3D) printed interim resins is unclear but influenced by printing parameters. Evidence regarding standardization of the postpolymerization type and time for 3D printed interim resins is sparse.Purpose. The purpose of this in vitro study was to evaluate the influence of postpolymerization type and time on flexural strength and dimensional stability of 3D printed resins for interim restorations.Material and methods. A total of 288 bars were 3D printed (Form 2; Formlabs, stereolithography-SLA, 50 mu m, 30 degrees), (25x2x2 mm; International Organization for Standardization-ISO 4049:2019) abraded and randomly divided into 9 groups (n=30) according to postpolymerization (Ultraviolet device-UV; Microwave with water-MWA; Microwave without water-MW) and time (15, 20, and 30 minutes for UV; and 5, 8, and 10 minutes for MW and MWA). Each bar was then measured with digital calipers at 11 points for length, thickness, and width before and after postpolymerization to analyze dimensional stability. The flexural strength was then measured (sigma; 980.6 N, 1 mm/minute) and the fractured surfaces were analyzed with scanning electron microscopy. The sigma (MPa) data were evaluated by using a 2-way analysis of variance (ANOVA) and the Tukey honestly significant difference (HSD) pairwise comparisons test (alpha=.05). Dimensional stability data (mm) were analyzed by using the Kruskal-Wallis test and Dwass-Steel-Critchlow-Fligner multiple comparisons. The Weibull analysis was performed with sigma data.Results. The 2-way ANOVA revealed that all factors and their interaction were significant for sigma (P<.001). The UV groups presented the highest sigma values, being statistically higher than all MW and MWA groups. The Weibull analysis revealed that postpolymerization UV groups found the highest values regarding the characteristic strength, although the MW 8-minute group (13.71) found the highest value for the Weibull modulus. Furthermore, the Kruskal-Wallis test revealed that only the postpolymerization factor was significant for dimensional stability (P<.001). The postpolymerization microwave groups found greater expansion variations at all times, with the MW 8-minute group (0.78 +/- 0.54) presenting the greatest variation in dimensional stability.Conclusions. UV was determined to be the most suitable type of postpolymerization for interim printed resin among the postpolymerization methods, regardless of the application time. The postpolymerization MW groups found greater variations in dimensional stability.
引用
收藏
页码:796.e1 / 796.e8
页数:8
相关论文
共 34 条
[1]   Effect of post-curing light exposure time on the physico-mechanical properties and cytotoxicity of 3D-printed denture base material [J].
Aati, Sultan ;
Akram, Zohaib ;
Shrestha, Barsha ;
Patel, Jainish ;
Shih, Benjamin ;
Shearston, Kate ;
Ngo, Hien ;
Fawzy, Amr .
DENTAL MATERIALS, 2022, 38 (01) :57-67
[2]   Three-dimensional evaluation of marginal and internal fit of 3D-printed interim restorations fabricated on different finish line designs [J].
Alharbi, Nawal ;
Alharbi, Saud ;
Cuijpers, Vincent M. J. I. ;
Osmane, Reham B. ;
Wismeijer, Daniel .
JOURNAL OF PROSTHODONTIC RESEARCH, 2018, 62 (02) :218-226
[3]   Effect of Printing Layer Thickness and Postprinting Conditions on the Flexural Strength and Hardness of a 3D-Printed Resin [J].
Alshamrani, Abdullah A. ;
Raju, Raju ;
Ellakwa, Ayman .
BIOMED RESEARCH INTERNATIONAL, 2022, 2022
[4]   Effects of Postcuring Temperature on the Mechanical Properties and Biocompatibility of Three-Dimensional Printed Dental Resin Material [J].
Bayarsaikhan, Enkhjargal ;
Lim, Jung-Hwa ;
Shin, Seung-Ho ;
Park, Kyu-Hyung ;
Park, Young-Bum ;
Lee, Jae-Hoon ;
Kim, Jong-Eun .
POLYMERS, 2021, 13 (08)
[5]   Does microwave disinfection affect the dimensional stability of denture base acrylic resins? A systematic review [J].
da Costa, Rodrigo Moreira Bringel ;
Venante, Helena Sandrini ;
Pordeus, Mariana Domingues ;
Chappuis-Chocano, Ana Paula ;
Neppelenbroek, Karin Hermana ;
Santiago Junior, Joel Ferreira ;
Porto, Vinicius Carvalho .
GERODONTOLOGY, 2022, 39 (04) :339-347
[6]  
Daneu Gabriel D, 2020, Acta odontol. latinoam., V33, P221
[7]   Effect of build orientation in accuracy, flexural modulus, flexural strength, and microhardness of 3D-Printed resins for provisional restorations [J].
de Castro, Eduardo F. ;
Nima, Gabriel ;
Rueggeberg, Frederick A. ;
Giannini, Marcelo .
JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2022, 136
[8]  
Digholkar Shruti, 2016, J Indian Prosthodont Soc, V16, P328
[9]   The influence of printing angle on color and translucency of 3D printed resins for dental restorations [J].
Espinar, Cristina ;
Della Bona, Alvaro ;
Perez, Maria M. ;
Tejada-Casado, Maria ;
Pulgar, Rosa .
DENTAL MATERIALS, 2023, 39 (04) :410-417
[10]   The occlusal precision of milled versus printed provisional crowns [J].
Giannetti, Luca ;
Apponi, Roberto ;
Mordini, Lorenzo ;
Presti, Sara ;
Breschi, Lorenzo ;
Mintrone, Francesco .
JOURNAL OF DENTISTRY, 2022, 117