Patient shielding during dentomaxillofacial radiography Recommendations from the American Academy of Oral and Maxillofacial Radiology

被引:21
作者
Benavides, Erika [1 ]
Bhula, Avni [2 ]
Gohel, Anita [3 ]
Lurie, Alan G. [4 ]
Mallya, Sanjay M. [2 ]
Ramesh, Aruna [5 ]
Tyndall, Donald A. [6 ]
机构
[1] Univ Michigan, Sch Dent, Dept Periodont & Oral Med, Ann Arbor, MI USA
[2] Univ Calif Los Angeles, Sch Dent, Sect Oral & Maxillofacial Radiol, 10833 Le Conte Ave, Los Angeles, CA 90095 USA
[3] Univ Florida, Coll Dent, Dept Oral & Maxillofacial Diagnost Sci, Gainesville, FL USA
[4] Univ Connecticut, Sch Dent Med, Div Oral & Maxillofacial Radiol, Farmington, CT USA
[5] Tufts Univ, Sch Dent Med, Div Oral & Maxillofacial Radiol, Boston, MA USA
[6] Univ North Carolina Chapel Hill, Adams Sch Dent, Dept Diagnost Sci, Sect Oral & Maxillofacial Radiol, Chapel Hill, NC USA
关键词
Radiation effects; radiation shielding; radiation protection; thyroid collar; lead apron; BEAM COMPUTED-TOMOGRAPHY; POSITION STATEMENT; DOSE REDUCTION; RISK; DOSIMETRY; RADIATION; CANCER; CT; COLLIMATION; PROTECTION;
D O I
10.1016/j.adaj.2023.06.015
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Background. The American Academy of Oral and Maxillofacial Radiology established an ad hoc committee to draft evidence-based recommendations and clinical guidance for the application of patient contact shielding during dentomaxillofacial imaging. Types of Studies Reviewed. The committee reviewed monographs and reports from radiation protection organizations and studies that reported radiation dose to gonads, breasts, and thyroid gland from dentomaxillofacial imaging. Results. Considering the absence of radiation-induced heritable effects in humans and the negligible dose to the gonads and fetus from dentomaxillofacial imaging, the committee recommends discontinuing shielding of the gonads, pelvic structures, and fetuses during all dentomaxillofacial radiographic imaging procedures. On the basis of radiation doses from contemporaneous maxillofacial imaging, the committee considered that the risks from thyroid cancer are negligible and recommends that thyroid shielding not be used during intraoral, panoramic, cephalometric, and cone-beam computed tomographic imaging. Practical Implications. This position statement informs and educates the reader on evolving radiation protection practices and provides simple, unequivocal guidance to dental personnel to implement these guidelines. State and local authorities should be contacted to update regulations to reflect these recommendations.
引用
收藏
页码:826 / 835.e2
页数:12
相关论文
共 65 条
[31]  
Johnson K. Brandon, 2014, General Dentistry, V62, P34
[32]   Radiation exposure to foetus and breasts from dental X-ray examinations: effect of lead shields [J].
Kelaranta, Anna ;
Ekholm, Marja ;
Toroi, Paula ;
Kortesniemi, Mika .
DENTOMAXILLOFACIAL RADIOLOGY, 2016, 45 (01)
[33]   Conversion coefficients for the estimation of effective dose in cone-beam CT [J].
Kim, Dong-Soo ;
Rashsuren, Oyuntugs ;
Kim, Eun-Kyung .
IMAGING SCIENCE IN DENTISTRY, 2014, 44 (01) :21-29
[34]   Efficacy of the Monte Carlo method and dose reduction strategies in paediatric panoramic radiography [J].
Lee, Chena ;
Park, Bora ;
Lee, Sam-Sun ;
Kim, Jo-Eun ;
Han, Sang-Sun ;
Huh, Kyung-Hoe ;
Yi, Won-Jin ;
Heo, Min-Suk ;
Choi, Soon-Chul .
SCIENTIFIC REPORTS, 2019, 9 (1)
[35]   ESTIMATING RADIATION DOSE TO MAJOR ORGANS IN DENTAL X-RAY EXAMINATIONS: A PHANTOM STUDY [J].
Li, Yong ;
Huang, Bingsheng ;
Cao, Jun ;
Fang, Tianqi ;
Liu, Guoqing ;
Li, Xuguang ;
Wu, Jiabao .
RADIATION PROTECTION DOSIMETRY, 2020, 192 (03) :328-334
[36]   Effective dose of dental CBCT-a meta analysis of published data and additional data for nine CBCT units [J].
Ludlow, J. B. ;
Timothy, R. ;
Walker, C. ;
Hunter, R. ;
Benavides, E. ;
Samuelson, D. B. ;
Scheske, M. J. .
DENTOMAXILLOFACIAL RADIOLOGY, 2015, 44 (01)
[37]   A manufacturer's role in reducing the dose of cone beam computed tomography examinations: effect of beam filtration [J].
Ludlow, J. B. .
DENTOMAXILLOFACIAL RADIOLOGY, 2011, 40 (02) :115-122
[38]   Dosimetry of two extraoral direct digital imaging devices: NewTom cone beam CT and Orthophos Plus DS panoramic unit [J].
Ludlow, JB ;
Davies-Ludlow, LE ;
Brooks, SL .
DENTOMAXILLOFACIAL RADIOLOGY, 2003, 32 (04) :229-234
[39]   Patient risk related to common dental radiographic examinations - The impact of 2007 International Commission on Radiological Protection recommendations regarding dose calculation [J].
Ludlow, John B. ;
Davies-Ludlow, Laura E. ;
White, Stuart C. .
JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 2008, 139 (09) :1237-1243
[40]  
Ludlow John B., 2009, Imaging Science in Dentistry, V39, P175