Biomechanical analysis of different osteosynthesis configurations in the pin and plate fixation method for distal humerus fractures

被引:4
作者
Hakiminejad, Alireza [1 ]
Nourani, Amir [1 ]
Ghias, Narges [1 ]
Mahmoudi, Alireza [1 ]
Same, Kaveh [2 ]
Kamrani, Reza Shahriar [3 ]
Nabian, Mohammad Hossein [4 ]
机构
[1] Sharif Univ Technol, Dept Mech Engn, Tehran, Iran
[2] Univ Tehran Med Sci, Sch Med, Tehran, Iran
[3] Univ Tehran Med Sci, Dept Orthoped & Trauma Surg, Tehran, Iran
[4] Univ Tehran Med Sci, Ctr Orthoped Transdisciplinary Appl Res COTAR, Tehran, Iran
关键词
Persian fixation method; Distal humerus fracture; Stability; Biomechanical testing; Osteosynthesis; INTERNAL-FIXATION; PARALLEL; SYSTEMS; STABILITY;
D O I
10.1186/s12891-023-06709-y
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Distal humerus fractures commonly occur in adults with low bone mineral density causing major technical challenges for orthopedic surgeons. Persian fixation method was introduced as a novel technique to stabilize small fragments in comminuted distal humerus fractures using a set of K-wires and a reconstruction plate. The present study aims to measure this technique's stiffness and stability of this technique and analyze the effect of influential parameters with numerical simulation and biomechanical testing on a cadaveric specimen. Validation of the finite element (FE) model was conducted based on results of experiments. The results indicated that Delta configuration mainly led to a higher stiffness in the case of axial loading and anterior bending compared to L configuration. Analyzing the influential factors of this technique suggests that changes in diameter and number of K-wires have a similarly significant effect on the construct stiffness while the height of plate had a slight influence. Also, the diameter of wires was the most effective parameter for implant failure, particularly in the 3-pin construct, which caused a reduction in failure risk by about 60%. The results revealed that the Persian fixation method would achieve suitable stability compared to the dual-plating technique.
引用
收藏
页数:14
相关论文
共 31 条
[1]   Spatial mapping of humeral head bone density [J].
Alidousti, Hamidreza ;
Giles, Joshua W. ;
Emery, Roger J. H. ;
Jeffers, Jonathan .
JOURNAL OF SHOULDER AND ELBOW SURGERY, 2017, 26 (09) :1653-1661
[2]   A biomechanical comparison of plate configuration in distal humerus fractures [J].
Arnander, Magnus W. T. ;
Reeves, Alexander ;
MacLeod, Iain A. R. ;
Pinto, Thomas M. ;
Khaleel, Arshad .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2008, 22 (05) :332-336
[3]   Biomechanical study of different plate configurations for distal humerus osteosynthesis [J].
Bogataj, M. ;
Kosel, F. ;
Norris, R. ;
Krkovic, M. ;
Brojan, M. .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2015, 53 (05) :381-392
[4]  
Castoldi F., 2015, Simple and Complex Fractures of the Humerus, P279, DOI DOI 10.1007/978-88-470-5307-6
[5]   Total elbow arthroplasty as primary treatment for distal humeral fractures in elderly patients [J].
Cobb, TK ;
Morrey, BF .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1997, 79A (06) :826-832
[6]   Biomechanical Comparison of Parallel Versus 90-90 Plating of Bicolumn Distal Humerus Fractures With Intra-Articular Comminution [J].
Got, Christopher ;
Shuck, John ;
Biercevicz, Alison ;
Paller, Dave ;
Mulcahey, Mary ;
Zimmermann, Matthew ;
Blaine, Theodore ;
Green, Andrew .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2012, 37A (12) :2512-2518
[7]   Outcome after open reduction and angular stable internal fixation for supra-intercondylar fractures of the distal humerus: preliminary results with the LCP distal humerus system [J].
Greiner, S. ;
Haas, N. P. ;
Bail, H. J. .
ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2008, 128 (07) :723-729
[8]  
Helfet D L, 1990, J Orthop Trauma, V4, P260, DOI 10.1097/00005131-199004030-00004
[9]   The number of screws, bone quality, coefficient affect acetabular cup and friction stability [J].
Hsu, Jui-Ting ;
Chang, Chih-Han ;
Huang, Heng-Li ;
Zobitz, Mark E. ;
Chen, Weng-Pin ;
Lai, Kuo-An ;
An, Kai-Nan .
MEDICAL ENGINEERING & PHYSICS, 2007, 29 (10) :1089-1095
[10]   Modified pin and plate fixation for low intercondylar fractures of the humerus: biomechanical study corroborated with a case series [J].
Jitprapaikulsarn S. ;
Chantarapanich N. ;
Gromprasit A. ;
Mahaisavariya C. ;
Patamamongkonchai C. .
MUSCULOSKELETAL SURGERY, 2023, 107 (2) :207-221