High-Accuracy Film-Integrated Optical Sensor for Real-Time Intraocular Pressure Monitoring

被引:3
作者
Xu, Xiaobin [1 ]
Liu, Zixuan [1 ]
Wang, Liqiang [2 ]
Huang, Yifei [2 ]
Yang, He [1 ]
机构
[1] Beihang Univ, Sch Instrumentat & Optoelect Engn, Beijing 100191, Peoples R China
[2] Chinese Peoples Liberat Army Gen Hosp, Med Sch Chinese PLA, Dept Ophthalmol, Beijing 100853, Peoples R China
关键词
glaucoma; intraocular pressure (IOP); implantable IOP sensor; interferometry; CONTACT-LENS SENSOR; CORNEAL THICKNESS; GLAUCOMA; PROGRESSION;
D O I
10.3390/mi14020353
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Intraocular pressure (IOP) is a key indicator to evaluate the risk and status of glaucoma, which is one of the main causes of irreversible blindness. However, the IOP value is susceptible to circadian changes and is difficult to be measured real-time. In this paper, we designed a thin-film integrated optical IOP sensor based on the interferometry principle, which could read out the IOP value by interference patterns and monitor the value changes real-time at the same time. The theoretical and experimental results indicated that our sensor exhibited a sensitivity of 0.19 mu m/mmHg and an average accuracy of 0.84 mmHg over the pressure range of 0-45 mmHg, which is comparable with the other reported optical systems but with the advantage of easier fabrication process and low-cost. Our sensor device implies great potential in the application of human physiological index measurement and other chip-integrated medical sensing instruments.
引用
收藏
页数:10
相关论文
共 26 条
[21]   Correlation between office and peak nocturnal intraocular pressures in healthy subjects and glaucoma patients [J].
Mosaed, S ;
Liu, JHK ;
Weinreb, RN .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2005, 139 (02) :320-324
[22]   Design of an Optical Pressure Measurement System for Intraocular Pressure Monitoring [J].
Phan, Alex ;
Phuong Truong ;
Trumpp, Julian ;
Talke, Frank E. .
IEEE SENSORS JOURNAL, 2018, 18 (01) :61-68
[23]   Global Prevalence of Glaucoma and Projections of Glaucoma Burden through 2040 A Systematic Review and Meta-Analysis [J].
Tham, Yih-Chung ;
Li, Xiang ;
Wong, Tien Y. ;
Quigley, Harry A. ;
Aung, Tin ;
Cheng, Ching-Yu .
OPHTHALMOLOGY, 2014, 121 (11) :2081-2090
[24]   Intraocular Pressure Measurement by Radio Wave Telemetry [J].
Todani, Amit ;
Behlau, Irmgard ;
Fava, Mark A. ;
Cade, Fabiano ;
Cherfan, Daniel G. ;
Zakka, Fouad R. ;
Jakobiec, Frederick A. ;
Gao, Yuqing ;
Dohlman, Claes H. ;
Melki, Samir A. .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2011, 52 (13) :9573-9580
[25]  
Wang Y.W.L.L.H., 2017, CHIN J MOD NURS, V23, P292
[26]   Wearable and Implantable Intraocular Pressure Biosensors: Recent Progress and Future Prospects [J].
Yang, Cheng ;
Huang, Xinshuo ;
Li, Xiangling ;
Yang, Chengduan ;
Zhang, Tao ;
Wu, Qianni ;
Liu, Dong ;
Lin, Haotian ;
Chen, Weirong ;
Hu, Ning ;
Xie, Xi .
ADVANCED SCIENCE, 2021, 8 (06)