High-Accuracy Film-Integrated Optical Sensor for Real-Time Intraocular Pressure Monitoring

被引:3
作者
Xu, Xiaobin [1 ]
Liu, Zixuan [1 ]
Wang, Liqiang [2 ]
Huang, Yifei [2 ]
Yang, He [1 ]
机构
[1] Beihang Univ, Sch Instrumentat & Optoelect Engn, Beijing 100191, Peoples R China
[2] Chinese Peoples Liberat Army Gen Hosp, Med Sch Chinese PLA, Dept Ophthalmol, Beijing 100853, Peoples R China
关键词
glaucoma; intraocular pressure (IOP); implantable IOP sensor; interferometry; CONTACT-LENS SENSOR; CORNEAL THICKNESS; GLAUCOMA; PROGRESSION;
D O I
10.3390/mi14020353
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Intraocular pressure (IOP) is a key indicator to evaluate the risk and status of glaucoma, which is one of the main causes of irreversible blindness. However, the IOP value is susceptible to circadian changes and is difficult to be measured real-time. In this paper, we designed a thin-film integrated optical IOP sensor based on the interferometry principle, which could read out the IOP value by interference patterns and monitor the value changes real-time at the same time. The theoretical and experimental results indicated that our sensor exhibited a sensitivity of 0.19 mu m/mmHg and an average accuracy of 0.84 mmHg over the pressure range of 0-45 mmHg, which is comparable with the other reported optical systems but with the advantage of easier fabrication process and low-cost. Our sensor device implies great potential in the application of human physiological index measurement and other chip-integrated medical sensing instruments.
引用
收藏
页数:10
相关论文
共 26 条
  • [1] A wireless batch sealed absolute capacitive pressure sensor
    Akar, O
    Akin, T
    Najafi, K
    [J]. SENSORS AND ACTUATORS A-PHYSICAL, 2001, 95 (01) : 29 - 38
  • [2] An implantable microfluidic device for self-monitoring of intraocular pressure
    Araci, Ismail E.
    Su, Baolong
    Quake, Stephen R.
    Mandel, Yossi
    [J]. NATURE MEDICINE, 2014, 20 (09) : 1074 - 1078
  • [3] Fluctuation of intraocular pressure and glaucoma progression in the early manifest glaucoma trial
    Bengtsson, Boel
    Leske, M. Cristina
    Hyman, Leslie
    Heijl, Anders
    [J]. OPHTHALMOLOGY, 2007, 114 (02) : 205 - 209
  • [4] Bhan A, 2002, INVEST OPHTH VIS SCI, V43, P1389
  • [5] Soft wearable contact lens sensor for continuous intraocular pressure monitoring
    Chen, Guo-Zhen
    Chan, Ion-Seng
    Leung, Leo K. K.
    Lam, David C. C.
    [J]. MEDICAL ENGINEERING & PHYSICS, 2014, 36 (09) : 1134 - 1139
  • [6] Capacitive contact lens sensor for continuous non-invasive intraocular pressure monitoring
    Chen, Guo-Zhen
    Chan, Ion-Seng
    Lam, David C. C.
    [J]. SENSORS AND ACTUATORS A-PHYSICAL, 2013, 203 : 112 - 118
  • [7] Chen P.J., 2008, P IEEE 2008 IEEE 21
  • [8] Wireless Intraocular Pressure Sensing Using Microfabricated Minimally Invasive Flexible-Coiled LC Sensor Implant
    Chen, Po-Jui
    Saati, Saloomeh
    Varma, Rohit
    Humayun, Mark S.
    Tai, Yu-Chong
    [J]. JOURNAL OF MICROELECTROMECHANICAL SYSTEMS, 2010, 19 (04) : 721 - 734
  • [9] Microfabricated Implantable Parylene-Based Wireless Passive Intraocular Pressure Sensors
    Chen, Po-Jui
    Rodger, Damien C.
    Saati, Saloomeh
    Humayun, Mark S.
    Tai, Yu-Chong
    [J]. JOURNAL OF MICROELECTROMECHANICAL SYSTEMS, 2008, 17 (06) : 1342 - 1351
  • [10] De Moraes CGV, 2011, ARCH OPHTHALMOL-CHIC, V129, P562, DOI 10.1001/archophthalmol.2011.72