The influence of a novel ribbed wave tape on the enhancement of heat transfer in a solar air heater operating in a transitional flow regime: an experimental study

被引:5
作者
Bhattacharyya, Suvanjan [1 ,2 ]
Vishwakarma, Devendra Kumar [1 ]
Soni, Manoj K. [1 ]
机构
[1] Birla Inst Technol & Sci Pilani, Dept Mech Engn, Jhunjhunu, India
[2] Birla Inst Technol & Sci Pilani, Dept Mech Engn, Pilani Campus,Vidya Vihar, Jhunjhunu 333031, India
关键词
Turbulators; ribbed wavy tapes; transition flow regime; Nusselt number; friction factor; PRESSURE-DROP CHARACTERISTICS; CIRCULAR TUBE; TRANSFER PERFORMANCE; FORCED-CONVECTION; INLET GEOMETRIES; FRICTION FACTOR; TURBULENT; LAMINAR; INSERTS; WATER;
D O I
10.1080/08916152.2023.2265208
中图分类号
O414.1 [热力学];
学科分类号
摘要
The effect of a novel ribbed wave tape on the augmentation of heat transfer in a solar air heater operating in a transitional flow regime is experimentally examined. Three different wave ratios are used, and the tube is uniformly heated using heat fluxes while the Reynolds number varied from 521 to 10,194. The transition for plain tube begins at 2810 and ends at 3724. For tube with ribbed wavy tapes, transition begins early and ends at higher Reynolds number than plain tube. For 2 kW/m2 of heat flux, the transition for wavy tape having wave ratio 3 begins at Reynolds number 2589 while at heat flux of 4 kW/m2, the transition begins at Reynolds number 2745. The end of transition takes place at Reynolds number 3969 and 4139 for wave ratio 3 at heat fluxes 2 and 4 kW/m2, respectively. The length of transition decreases with increase in the wave ratio at uniform heat flux. The average enhancement in Nusselt number for ribbed wavy tapes having wave ratio 3 at 4 kW/m2 heat flux was 262% and 85% for laminar and turbulent flow regime, respectively. Two empirical correlations were developed to predict the Nusselt number and friction factor for all the flow regimes.
引用
收藏
页码:1100 / 1118
页数:19
相关论文
共 69 条
[61]  
Vishwakarma D. K., 2023, EFFECT INLET FLAP OB, V3, P455, DOI [10.1007/978-981-19-6270-7_76, DOI 10.1007/978-981-19-6270-7_76]
[62]  
White FM, 2011, FLUID MECH-SOV RES
[63]   Heat transfer augmentation of internal flow using twisted tape insert in turbulent flow [J].
Wijayanta, Agung Tri ;
Mirmanto ;
Aziz, Muhammad .
HEAT TRANSFER ENGINEERING, 2020, 41 (14) :1288-1300
[64]   Double-sided delta-wing tape inserts to enhance convective heat transfer and fluid flow characteristics of a double-pipe heat exchanger [J].
Wijayanta, Agung Tri ;
Yaningsih, Indri ;
Aziz, Muhammad ;
Miyazaki, Takahiko ;
Koyama, Shigeru .
APPLIED THERMAL ENGINEERING, 2018, 145 :27-37
[65]  
Withers J.G., 1980, Heat Transfer Engineering, V2, P48, DOI DOI 10.1080/01457638008962750
[66]   Experimental Study of Heat Transfer Enhancement in a Concentric Double Pipe Heat Exchanger with Different Axial Pitch Ratio of Perforated Twisted Tape Inserts [J].
Yaningsih, Indri ;
Istanto, Tri ;
Wijayanta, Agung Tri .
PROCEEDINGS OF THE 4TH INTERNATIONAL CONFERENCE AND EXHIBITION OF SUSTAINABLE ENERGY AND ADVANCED MATERIALS 2015 (ICE-SEAM 2015), 2016, 1717
[67]   Numerical study on turbulent heat transfer performance of a new parallel-flow shell and tube heat exchanger with sinusoidal wavy tapes using RSM analysis [J].
Yu, Chulin ;
Chen, Jian ;
Zeng, Min ;
Gao, Bingjun .
APPLIED THERMAL ENGINEERING, 2019, 150 :875-887
[68]   A novel wavy-tape insert configuration for pipe heat transfer augmentation [J].
Zhu, Xiao Wei ;
Fu, Yun Han ;
Zhao, Jing Quan .
ENERGY CONVERSION AND MANAGEMENT, 2016, 127 :140-148
[69]   Wavy-tape insert designed for managing highly concentrated solar energy on absorber tube of parabolic trough receiver [J].
Zhu, Xiaowei ;
Zhu, Lei ;
Zhao, Jingquan .
ENERGY, 2017, 141 :1146-1155