The deformities of acute diaphyseal clavicular fractures: a three-dimensional analysis

被引:0
|
作者
Chao, Yi-Hsuan [1 ,2 ,3 ]
Chou, Ying-Chao [4 ]
Lin, Chun-Li [1 ,3 ]
机构
[1] Natl Yang Ming Chiao Tung Univ, Dept Biomed Engn, 155,Sec 2,Linong St, Taipei 112, Taiwan
[2] Taipei City Hosp, Dept Orthopaed Surg, 10,Sec 4,Renai Rd, Taipei 106, Taiwan
[3] Natl Yang Ming Chiao Tung Univ, Innovat & Translat Ctr Med Device, 155,Sec 2,Linong St, Taipei 112, Taiwan
[4] Chang Gung Mem Hosp, Dept Orthoped, 5 Fuxing St, Taoyuan 333, Taiwan
关键词
Clavicle; Fracture; Diaphyseal clavicular fracture; Shortening; Computed tomography; 3D;
D O I
10.1186/s12938-023-01112-z
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
BackgroundAlthough minimally invasive surgeries have gained popularity in many orthopaedic fields, minimally invasive approaches for diaphyseal clavicular fracture have not been widely performed, which is attributed to difficulties in performing a closed reduction of fracture deformities of a curved bone in a three-dimensional space. The goal of this study was to investigate the radiographic parameters of fracture deformities in a three-dimensional space and to identify the risk factors for deformities.MethodsThe computed tomography images of 100 patients who sustained a clavicle fracture were included. Five parameters were used to analyze the deformities: change in clavicle length, fracture displacement, and fragment rotation around the X, Y, Z axes. The change in length was assessed using the length of the endpoint line. The displacement was assessed using the distance between the fracture midpoints. The rotation deformities were assessed using the Euler angles. The correlation between the parameters was evaluated with the Pearson correlation coefficient. The risk factors were evaluated using univariable analysis and multiple regression analysis.ResultsThe average change in length was - 5.3 +/- 8.3 mm. The displacement was 11.8 +/- 7.1 mm. The Euler angles in the Z-Y-X sequences were -1 +/- 8, 1 +/- 8, and - 8 +/- 13 degrees. The correlation coefficient between the change in length and the displacement was - 0.724 (p < 0.001). The variables found to increase the risk of shortening and displacement were right-sided fracture (p = 0.037), male sex (p = 0.015), and multifragmentary type (p = 0.020). The variables found to increase the risk of rotation deformity were the number of rib fractures (p = 0.001) and scapula fracture (p = 0.025).ConclusionsThere was a strong correlation between shortening and displacement. The magnitude of anterorotation around the X axis was greater than the magnitude of retraction around the Z axis and depression around the Y axis. The risk factors for shortening and displacement included right-sided fracture, male sex, and multifragmentary type. The risk factor for retraction around the Z axis was the number of rib fractures, and the risk factor for depression around the Y axis was scapula fracture. These results could be useful adjuncts in guiding minimally invasive surgical planning for diaphyseal clavicular fractures.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] The deformities of acute diaphyseal clavicular fractures: a three-dimensional analysis
    Yi-Hsuan Chao
    Ying-Chao Chou
    Chun-Li Lin
    BioMedical Engineering OnLine, 22
  • [2] In Vivo Analysis of Three-Dimensional Dynamic Scapular Dyskinesis in Scapular or Clavicular Fractures
    Kim, Eugene
    Park, Jai Hyung
    Han, Byeong-Ryong
    Park, Hee Jin
    Lee, So Yeon
    Murase, Tsuyoshi
    Sugamoto, Kazuomi
    Ikemoto, Sumika
    Park, Se-Jin
    ACTA MEDICA OKAYAMA, 2017, 71 (02) : 151 - 159
  • [3] Three-Dimensional Deformities of Nonoperative Midshaft Clavicle Fractures: A Surface Matching Analysis
    Oki, Satoshi
    Matsumura, Noboru
    Kiriyama, Yoshimori
    Iwamoto, Takuji
    Sato, Kazuki
    Nagura, Takeo
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2017, 31 (11) : E385 - E389
  • [4] In Vivo Three-Dimensional Analysis of Malunited Forearm Diaphyseal Fractures with Forearm Rotational Restriction
    Abe, Shingo
    Murase, Tsuyoshi
    Oka, Kunihiro
    Shigi, Atsuo
    Tanaka, Hiroyuki
    Yoshikawa, Hideki
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2018, 100 (17):
  • [5] The anatomy of acute scaphoid fractures - A three-dimensional analysis of patterns
    Compson, JP
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1998, 80B (02): : 218 - 224
  • [6] Limb deformities and three-dimensional ultrasound
    Kos, M
    Hafner, T
    Funduk-Kurjak, B
    Bozek, T
    Kurjak, A
    JOURNAL OF PERINATAL MEDICINE, 2002, 30 (01) : 40 - 47
  • [7] Shortening deformities of the clavicle after diaphyseal clavicular fractures. Influence on patient-oriented assessment of shoulder function
    Jubel, A.
    Schiffer, G.
    Andermahr, J.
    Ries, C.
    Faymonville, C.
    UNFALLCHIRURG, 2016, 119 (06): : 508 - 516
  • [8] Fracture edge features of diaphyseal clavicular fractures: a morphologic study
    Chao, Yi-Hsuan
    Chou, Ying-Chao
    Lin, Chun-Li
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2023, 32 (01) : 192 - 200
  • [9] Three-dimensional analysis system for orthognathic surgery patients with jaw deformities
    Terajima, Masahiko
    Yanagita, Natsumi
    Ozeki, Kanako
    Hoshino, Yoshihiro
    Mori, Noriko
    Goto, Tazuko K.
    Tokumori, Kenji
    Aoki, Yoshimitsu
    Nakasima, Akihiko
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2008, 134 (01) : 100 - 111
  • [10] Computer graphics analysis of the three-dimensional deformities of scoliotic vertebrae.
    Landry, C
    DeGuise, JA
    Dansereau, J
    Labelle, H
    Skalli, W
    Zeller, R
    Lavaste, F
    ANNALES DE CHIRURGIE, 1997, 51 (08): : 868 - 874