Comparison of the hybrid and partial stent-in-stent method for endoscopic three-segment drainage for unresectable malignant hilar biliary obstruction

被引:1
作者
Yoshinari, Motohiro [1 ,2 ]
Hijioka, Susumu [1 ,3 ]
Nagashio, Yoshikuni [1 ]
Maruki, Yuta [1 ]
Ohba, Akihiro [1 ]
Kawasaki, Yuki [1 ]
Takeshita, Kotaro [1 ]
Morizane, Chigusa [1 ]
Tanaka, Yasuhito [2 ]
Okusaka, Takuji [1 ]
机构
[1] Natl Canc Ctr, Dept Hepatobiliary & Pancreat Oncol, Tokyo, Japan
[2] Kumamoto Univ, Fac Life Sci, Dept Gastroenterol & Hepatol, Kumamoto, Japan
[3] 5-1-1 Tsukiji,Chuo Ku, Tokyo 1040045, Japan
关键词
SIDE-BY-SIDE; METALLIC STENTS; REVISION EFFICACY; PLACEMENT; STRICTURES; DEPLOYMENT; CHOLANGIOCARCINOMA; FEASIBILITY;
D O I
10.1055/a-2039-3936
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background and study aims The clinical outcome of the new hybrid drainage method for unresectable malignant hilar biliary obstruction (UMHBO) has not yet been compared with that of the partial stent-in-stent (PSIS) method with three or more stents.Patients and methods Patients with UMHBO underwent drainage of three segments using the hybrid or PSIS method. The clinical outcomes of both methods were compared retrospectively.Results Overall, 54 patients underwent the hybrid (n = 31) or PSIS (n = 23) method of drainage with three or more stents for UMHBO. There were no significant differences in the technical success rate (hybrid vs. PSIS, 87.1 % vs. 87 %), clinical success rate according to per-protocol analysis (81.5 % vs. 70 %), early adverse events rate (14.8 % vs. 10%), late adverse events rate (7.4 % vs. 0 %), and technical success rate of the endoscopic transpapillary reintervention (90.9 % vs. 100 %). Time to recurrent biliary obstruction (TRBO) of the hybrid and PSIS methods was 178 and 231 days, respectively, with no significant difference ( P = 0.354).Conclusions The choice between the two methods should be made at the physician's discretion.
引用
收藏
页码:E276 / E283
页数:8
相关论文
共 28 条
[1]   Initial performance profile of a new 6F self-expanding metal stent for palliation of malignant hilar biliary obstruction [J].
Chennat, Jennifer ;
Waxman, Irving .
GASTROINTESTINAL ENDOSCOPY, 2010, 72 (03) :632-636
[2]   Endoscopic bilateral metal stent placement for malignant hilar stenoses: identification of optimal technique [J].
Dumas, R ;
Demuth, N ;
Buckley, M ;
Peten, EP ;
Manos, T ;
Demarquay, JF ;
Hastier, P ;
Caroli-Bosc, FX ;
Rampal, P ;
Delmont, JP .
GASTROINTESTINAL ENDOSCOPY, 2000, 51 (03) :334-338
[3]   Endoscopic biliary stenting: indications, choice of stents, and results: European Society of Gastrointestinal Endoscopy (ESGE) Clinical Guideline - Updated October 2017 [J].
Dumonceau, Jean-Marc ;
Tringali, Andrea ;
Papanikolaou, Ioannis S. ;
Blero, Daniel ;
Mangiavillano, Benedetto ;
Schmidt, Arthur ;
Vanbiervliet, Geoffroy ;
Costamagna, Guido ;
Deviere, Jacques ;
Garcia-Cano, Jesus ;
Gyoekeres, Tibor ;
Hassan, Cesare ;
Prat, Frederic ;
Siersema, Peter D. ;
van Hooft, Jeanin E. .
ENDOSCOPY, 2018, 50 (09) :910-930
[4]   Combined side-by-side and stent-in-stent method for triple metal stenting in patients with malignant hilar biliary obstruction [J].
Inoue, Tadahisa ;
Ibusuki, Mayu ;
Kitano, Rena ;
Kobayashi, Yuji ;
Ohashi, Tomohiko ;
Nakade, Yukiomi ;
Sumida, Yoshio ;
Ito, Kiyoaki ;
Nakao, Haruhisa ;
Yoneda, Masashi .
DIGESTIVE ENDOSCOPY, 2019, 31 (06) :698-705
[5]   TOKYO criteria 2014 for transpapillary biliary stenting [J].
Isayama, Hiroyuki ;
Hamada, Tsuyoshi ;
Yasuda, Ichiro ;
Itoi, Takao ;
Ryozawa, Shomei ;
Nakai, Yousuke ;
Kogure, Hirofumi ;
Koike, Kazuhiko .
DIGESTIVE ENDOSCOPY, 2015, 27 (02) :259-264
[6]   Retrospective Comparative Study of Side-by-Side and Stent-in-Stent Metal Stent Placement for Hilar Malignant Biliary Obstruction [J].
Ishigaki, Kazunaga ;
Hamada, Tsuyoshi ;
Nakai, Yousuke ;
Isayama, Hiroyuki ;
Sato, Tatsuya ;
Hakuta, Ryunosuke ;
Saito, Kei ;
Saito, Tomotaka ;
Takahara, Naminatsu ;
Mizuno, Suguru ;
Kogure, Hirofumi ;
Ito, Yukiko ;
Yagioka, Hiroshi ;
Matsubara, Saburo ;
Akiyama, Dai ;
Mohri, Dai ;
Tada, Minoru ;
Koike, Kazuhiko .
DIGESTIVE DISEASES AND SCIENCES, 2020, 65 (12) :3710-3718
[7]   Endoscopic deployment of multiple JOSTENT SelfX is effective and safe in treatment of malignant hilar biliary strictures [J].
Kawamoto, Hirofumi ;
Tsutsumi, Koichiro ;
Harada, Ryo ;
Fuji, Masakuni ;
Kato, Hironari ;
Hirao, Ken ;
Kurihara, Naoko ;
Nakanishi, Takashi ;
Mizuno, Osamu ;
Ishida, Etsuji ;
Ogawa, Tsuneyoshi ;
Fukatsu, Hirotoshi ;
Sakaguchi, Kohsaku .
CLINICAL GASTROENTEROLOGY AND HEPATOLOGY, 2008, 6 (04) :401-408
[8]   Endoscopic 3-branched partial stent-in-stent deployment of metallic stents in high-grade malignant hilar biliary stricture [J].
Kawamoto, Hirofumi ;
Tsutsumi, Koichiro ;
Fujii, Masakuni ;
Harada, Ryo ;
Kato, Hironari ;
Hirao, Ken ;
Kurihara, Naoko ;
Nakanishi, Takashi ;
Mizuno, Osamu ;
Ishida, Etsuji ;
Ogawa, Tsuneyoshi ;
Fukatsu, Hirotoshi ;
Sakaguchi, Kohsaku .
GASTROINTESTINAL ENDOSCOPY, 2007, 66 (05) :1030-1037
[9]   High single-session success rate of endoscopic bilateral stent-in-stent placement with modified large cell Niti-S stents for malignant hilar biliary obstruction [J].
Kogure, Hirofumi ;
Isayama, Hiroyuki ;
Nakai, Yousuke ;
Tsujino, Takeshi ;
Matsubara, Saburo ;
Yashima, Yoko ;
Ito, Yukiko ;
Hamada, Tsuyoshi ;
Takahara, Naminatsu ;
Miyabayashi, Koji ;
Mizuno, Suguru ;
Mohri, Dai ;
Kawakubo, Kazumichi ;
Sasaki, Takashi ;
Yamamoto, Natsuyo ;
Hirano, Kenji ;
Sasahira, Naoki ;
Tada, Minoru ;
Koike, Kazuhiko .
DIGESTIVE ENDOSCOPY, 2014, 26 (01) :93-99
[10]   Newly designed large cell Niti-S stent for malignant hilar biliary obstruction: a pilot study [J].
Kogure, Hirofumi ;
Isayama, Hiroyuki ;
Nakai, Yousuke ;
Tsujino, Takeshi ;
Ito, Yukiko ;
Yamamoto, Keisuke ;
Mizuno, Suguru ;
Yagioka, Hiroshi ;
Kawakubo, Kazumichi ;
Sasaki, Takashi ;
Hirano, Kenji ;
Sasahira, Naoki ;
Tada, Minoru ;
Omata, Masao ;
Koike, Kazuhiko .
SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2011, 25 (02) :463-467