Efficacy and Safety of Pulsed Field Ablation in Atrial Fibrillation: A Systematic Review

被引:14
|
作者
Shtembari, Jurgen [1 ]
Shrestha, Dhan Bahadur [1 ]
Pathak, Bishnu Deep [2 ]
Dhakal, Bishal [3 ]
Regmi, Binit Upadhaya [2 ]
Patel, Nimesh K. K. [4 ]
Shantha, Ghanshyam Palamaner Subash [5 ]
Kalahasty, Gautham [6 ]
Kaszala, Karoly [6 ]
Koneru, Jayanthi N. N. [6 ]
机构
[1] Mt Sinai Hosp, Dept Internal Med, Chicago, IL 60608 USA
[2] Jibjibe Primary Hlth Care Ctr, Dept Internal Med, Jibjibe 45000, Nepal
[3] Nepalese Army Inst Hlth Sci, Dept Internal Med, Kathmandu 44600, Nepal
[4] Virginia Commonwealth Univ, Sch Med, Dept Internal Med, Div Cardiol, Richmond, VA 23219 USA
[5] Wake Forest Baptist Hlth, Dept Internal Med, Div Electrophysiol, Atrium Hlth, Med Ctr Blvd, Winston Salem, NC 27157 USA
[6] Virginia Commonwealth Univ, Sch Med, Dept Internal Med, Div Electrophysiol, Richmond, VA 23219 USA
关键词
atrial fibrillation; pulmonary vein isolation; catheter ablation; pulse-field ablation; PULMONARY VEIN ISOLATION; OUTCOMES;
D O I
10.3390/jcm12020719
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Atrial fibrillation (AF) is the most common cardiac arrhythmia associated with high morbidity and mortality. AF treatment is guided by a patient-provider risk-benefit discussion regarding drug versus ablation or combination. Thermal ablation has a high rate of adverse events compared to pulsed field ablation (PFA). In this systematic review, we aimed to determine the safety and efficacy of PFA. Methods: The electronic search for relevant articles in English was completed in PubMed, PubMed Central, Cochrane library, Scopus, and Embase databases till July 2022. The screening was completed via the use of Covidence software. The risk of bias assessment and data extraction from the included studies was performed, and the narrative synthesis was performed accordingly. Results: A total of six studies were selected for review and 1897 patients receiving PFA were involved in these studies. Our review was focused on pulmonary vein isolation success, major adverse events, and arrhythmia recurrence. Successful pulmonary vein isolation (PVI) was completed in 100% of cases except in two studies. In one of them, six out of seven patients (86%) in the epicardial cohort had successful PVI. In the MANIFEST-PF survey, the acute PVI success rate was 99.9%. The major complications were rare and included pericardial tamponade, vascular complications requiring surgery, and stroke. The atrial arrhythmia recurrence was higher in the thermal group than in the PFA group (39% vs. 11%). Conclusions: The success rate of PVI by PFA is high, and major adverse events are low. PFA is found to decrease the recurrence of atrial arrhythmia compared to thermal ablation. Substantial randomized controlled trials (RCTs) are needed to validate the efficacy and safety of PFA over conventional methods.
引用
收藏
页数:11
相关论文
共 50 条
  • [31] Safety and efficacy of atrial fibrillation ablation guided by Ablation Index module
    Solimene, Francesco
    Schillaci, Vincenzo
    Shopova, Gergana
    Urraro, Francesco
    Arestia, Alberto
    Iuliano, Assunta
    Maresca, Fabio
    Agresta, Alessia
    La Rocca, Vincenzo
    De Simone, Antonio
    Stabile, Giuseppe
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2019, 54 (01) : 9 - 15
  • [32] Focal Pulsed Field Ablation for Atrial Arrhythmias: Efficacy and Safety under Deep Sedation
    Weyand, Sebastian
    Adam, Viola
    Biehler, Paloma
    Haegele, Patricia
    Hanger, Simon
    Heinzmann, David
    Loebig, Stephanie
    Pinchuk, Andrei
    Waechter, Christian
    Seizer, Peter
    JOURNAL OF CLINICAL MEDICINE, 2024, 13 (02)
  • [33] Pulsed Field Ablation to Treat Paroxysmal Atrial Fibrillation: Safety and Effectiveness in the AdmIRE Pivotal Trial
    Reddy, Vivek Y.
    Calkins, Hugh
    Mansour, Moussa
    Wazni, Oussama
    Di Biase, Luigi
    Bahu, Marwan
    Newton, David
    Liu, Christopher F.
    Sauer, William H.
    Goyal, Sandeep
    Iyer, Vivek
    Nair, Devi
    Athill, Charles
    Hussein, Ayman
    Whalen, Patrick
    Melby, Daniel
    Natale, Andrea
    CIRCULATION, 2024, 150 (15) : 1174 - 1186
  • [34] Efficacy and safety of catheter ablation combined with left atrial appendage occlusion for nonvalvular atrial fibrillation: A systematic review and meta-analysis
    Jiang, Ying
    Li, Fanghui
    Li, Dongze
    Cheng, Yisong
    Jia, Yu
    Fu, Hua
    Pu, Xiaobo
    Hu, Hongde
    Jiang, Jian
    Zeng, Rui
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2020, 43 (01): : 123 - 132
  • [35] Pulsed Field or Conventional Thermal Ablation for Paroxysmal Atrial Fibrillation
    Reddy, Vivek Y.
    Gerstenfeld, Edward P.
    Natale, Andrea
    Whang, William
    Cuoco, Frank A.
    Patel, Chinmay
    Mountantonakis, Stavros E.
    Gibson, Douglas N.
    Harding, John D.
    Ellis, Christopher R.
    Ellenbogen, Kenneth A.
    DeLurgio, David B.
    Osorio, Jose
    Achyutha, Anitha B.
    Schneider, Christopher W.
    Mugglin, Andrew S.
    Albrecht, Elizabeth M.
    Stein, Kenneth M.
    Lehmann, John W.
    Mansour, Moussa
    NEW ENGLAND JOURNAL OF MEDICINE, 2023, 389 (18): : 1660 - 1671
  • [36] Pulsed Field Ablation for Pulmonary Vein Isolation in Atrial Fibrillation
    Reddy, Vivek Y.
    Neuzil, Petr
    Koruth, Jacob S.
    Petru, Jan
    Funosako, Moritoshi
    Cochet, Hubert
    Sediva, Lucie
    Chovanec, Milan
    Dukkipati, Srinivas R.
    Jais, Pierre
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2019, 74 (03) : 315 - 326
  • [37] Pulsed field ablation for atrial fibrillation - Lessons from magnetic resonance imaging
    Fink, Thomas
    Sciacca, Vanessa
    Neven, Kars
    Didenko, Maxim
    Sommer, Philipp
    Sohns, Christian
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2023, 46 (12): : 1586 - 1594
  • [38] Coronary Arterial Spasm During Pulsed Field Ablation to Treat Atrial Fibrillation
    Reddy, Vivek Y.
    Petru, Jan
    Funasako, Moritoshi
    Kopriva, Karel
    Hala, Pavel
    Chovanec, Milan
    Janotka, Marek
    Kralovec, Stepan
    Neuzil, Petr
    CIRCULATION, 2022, 146 (24) : 1808 - 1819
  • [39] Multielectrode catheter-based pulsed electric field vs. cryoballoon for atrial fibrillation ablation: a systematic review and meta-analysis
    Vetta, Giampaolo
    Della Rocca, Domenico Giovanni
    Parlavecchio, Antonio
    Magnocavallo, Michele
    Sorgente, Antonio
    Pannone, Luigi
    Del Monte, Alvise
    Almorad, Alexandre
    Sieira, Juan
    Marcon, Lorenzo
    Doundoulakis, Ioannis
    Mohanty, Sanghamitra
    Audiat, Charles
    Nakasone, Kazutaka
    Bala, Gezim
    Stroker, Erwin
    Combes, Stephane
    Overeinder, Ingrid
    Bianchi, Stefano
    Palmisano, Pietro
    Rossi, Pietro
    Boveda, Serge
    La Meir, Marc
    Natale, Andrea
    Sarkozy, Andrea
    de Asmundis, Carlo
    Chierchia, Gian-Battista
    EUROPACE, 2024, 26 (12):
  • [40] Feasibility, Safety, and Efficacy of Posterior Wall Isolation During Atrial Fibrillation Ablation A Systematic Review and Meta-Analysis
    Thiyagarajah, Anand
    Kadhim, Kadhim
    Lau, Dennis H.
    Emami, Mehrdad
    Linz, Dominik
    Khokhar, Kashif
    Munawar, Dian A.
    Mishima, Ricardo
    Malik, Varun
    O'Shea, Catherine
    Mahajan, Rajiv
    Sanders, Prashanthan
    CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2019, 12 (08):