Performance of visual, manual, and automatic coronary calcium scoring of cardiac 13N-ammonia PET/low dose CT

被引:3
|
作者
Dobrolinska, Magdalena M. [1 ,2 ,3 ]
Lazarenko, Sergiy, V [4 ]
van der Zant, Friso M. [4 ]
Does, Lonneke [4 ]
van der Werf, Niels [5 ,6 ]
Prakken, Niek H. J. [1 ,2 ,3 ]
Greuter, Marcel J. W. [1 ,2 ,3 ,7 ]
Slart, Riemer H. J. A. [1 ,2 ,3 ,8 ]
Knol, Remco J. J. [4 ]
机构
[1] Univ Groningen, Univ Med Ctr Groningen, Med Imaging Ctr, Dept Radiol, NL-9700 RB Groningen, Netherlands
[2] Univ Groningen, Univ Med Ctr Groningen, Med Imaging Ctr, Dept Nucl Med, NL-9700 RB Groningen, Netherlands
[3] Univ Groningen, Univ Med Ctr Groningen, Med Imaging Ctr, Dept Mol Imaging, NL-9700 RB Groningen, Netherlands
[4] Northwest Clin, Dept Nucl Med, Alkmaar, Netherlands
[5] Univ Utrecht, Univ Med Ctr Utrecht, Dept Radiol, Utrecht, Netherlands
[6] Erasmus MC, Dept Radiol & Nucl Med, Rotterdam, Netherlands
[7] Univ Twente, Dept Robot & Mechatron, Fac Elect Engn Math & Comp Sci, Enschede, Netherlands
[8] Univ Twente, Fac Sci & Technol, Dept Biomed Photon Imaging, Enschede, Netherlands
关键词
CAD; PET; CT; Image interpretation; CARDIOVASCULAR COMPUTED-TOMOGRAPHY; 2016 SCCT/STR GUIDELINES; ARTERY CALCIUM; ATTENUATION CORRECTION; CALCIFICATION; DISEASE; SCANS; ATHEROSCLEROSIS; QUANTIFICATION; PREDICTION;
D O I
10.1007/s12350-022-03018-0
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Coronary artery calcium is a well-known predictor of major adverse cardiac events and is usually scored manually from dedicated, ECG-triggered calcium scoring CT (CSCT) scans. In clinical practice, a myocardial perfusion PET scan is accompanied by a non-ECG triggered low dose CT (LDCT) scan. In this study, we investigated the accuracy of patients' cardiovascular risk categorisation based on manual, visual, and automatic AI calcium scoring using the LDCT scan. Methods We retrospectively enrolled 213 patients. Each patient received a N-13-ammonia PET scan, an LDCT scan, and a CSCT scan as the gold standard. All LDCT and CSCT scans were scored manually, visually, and automatically. For the manual scoring, we used vendor recommended software (Syngo.via, Siemens). For visual scoring a 6-points risk scale was used (0; 1-10; 11-100; 101-400; 401-100; > 1 000 Agatston score). The automatic scoring was performed with deep learning software (Syngo.via, Siemens). All manual and automatic Agatston scores were converted to the 6-point risk scale. Manual CSCT scoring was used as a reference. Results The agreement of manual and automatic LDCT scoring with the reference was low [weighted kappa 0.59 (95% CI 0.53-0.65); 0.50 (95% CI 0.44-0.56), respectively], but the agreement of visual LDCT scoring was strong [0.82 (95% CI 0.77-0.86)]. Conclusions Compared with the gold standard manual CSCT scoring, visual LDCT scoring outperformed manual LDCT and automatic LDCT scoring.
引用
收藏
页码:239 / 250
页数:12
相关论文
共 43 条
  • [31] 13N-Ammonia PET-CT for Evaluating Response to Antiangiogenic Therapy and Prognosis in Patients with Advanced Hepatocellular Carcinoma: A Pilot Study
    Scolozzi, Valentina
    Nicoletti, Alberto
    Capotosti, Amedeo
    Ponziani, Francesca Romana
    Taralli, Silvia
    Genco, Enza
    Leccisotti, Lucia
    Moretti, Roberto
    Indovina, Luca
    Pompili, Maurizio
    Calcagni, Maria Lucia
    CANCERS, 2025, 17 (04)
  • [32] Quantitative myocardial perfusion and coronary reserve in rats with 13N-ammonia and small animal PET:: Impact of anesthesia and pharmacologic stress agents
    Croteau, E
    Bénard, F
    Bentourkia, M
    Rousseau, J
    Paquette, M
    Lecomte, R
    JOURNAL OF NUCLEAR MEDICINE, 2004, 45 (11) : 1924 - 1930
  • [33] Automatic coronary calcium scoring in chest CT using a deep neural network in direct comparison with non-contrast cardiac CT: A validation study
    van Assen, Marly
    Martin, Simon S.
    Varga-Szemes, Akos
    Rapaka, Saikiran
    Cimen, Serkan
    Sharma, Puneet
    Sahbaee, Pooyan
    De Cecco, Carlo N.
    Vliegenthart, Rozemarjin
    Leonard, Tyler J.
    Burt, Jeremy R.
    Schoepf, U. Joseph
    EUROPEAN JOURNAL OF RADIOLOGY, 2021, 134
  • [34] The combination of 13N-ammonia and 18F-FDG whole-body PET/CT on the same day for diagnosis of advanced prostate cancer
    Yi, Chang
    Yu, Donglan
    Shi, Xinchong
    Zhang, Xiangsong
    Luo, Ganhua
    He, Qiao
    Zhang, Xuezhen
    NUCLEAR MEDICINE COMMUNICATIONS, 2016, 37 (03) : 239 - 246
  • [35] Performance of ultra-low-dose CT for the evaluation of coronary calcification: a direct comparison with coronary calcium score
    Silveira de Souza, V. V.
    Soares Torres, F.
    Hochhegger, B.
    Watte, G.
    Sartori, G.
    Lucchese, F.
    Azambuja Goncalves, B.
    CLINICAL RADIOLOGY, 2017, 72 (09) : 745 - 750
  • [36] Comparative evaluation of 18F-FDOPA, 13N-AMMONIA, 18F-FDG PET/CT and MRI in primary brain tumors - A pilot study
    Jora, Charu
    Mattakarottu, Jacob J.
    Aniruddha, Pandit G.
    Mudalsha, Ravina
    Singh, Dhananjay K.
    Pathak, Harish C.
    Sharma, Nitin
    Sarin, Arti
    Prince, Arvind
    Singh, Giriraj
    INDIAN JOURNAL OF NUCLEAR MEDICINE, 2011, 26 (02): : 78 - 81
  • [37] High-pitch low-voltage CT coronary artery calcium scoring with tin filtration: accuracy and radiation dose reduction
    Apfaltrer, Georg
    Albrecht, Moritz H.
    Schoepf, U. Joseph
    Duguay, Taylor M.
    De Cecco, Carlo N.
    Nance, John W.
    De Santis, Domenico
    Apfaltrer, Paul
    Eid, Marwen H.
    Eason, Chelsea D.
    Thompson, Zachary M.
    Bauer, Maximilian J.
    Varga-Szemes, Akos
    Jacobs, Brian E.
    Sorantin, Erich
    Tesche, Christian
    EUROPEAN RADIOLOGY, 2018, 28 (07) : 3097 - 3104
  • [38] Visual Ordinal Scoring of Coronary Artery Calcium on Contrast-Enhanced and Noncontrast Chest CT: A Retrospective Study of Diagnostic Performance and Prognostic Utility
    Fresno, Camila Urzua
    Sanchez Tijmes, Felipe
    Thavendiranathan, Paaladinesh
    Akhtari, Shadi
    Karur, Gauri Rani
    Torres, Felipe Soares
    Halankar, Jaydeep
    Nguyen, Elsie T.
    Hanneman, Kate
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2022, 219 (04) : 569 - 577
  • [39] Single low-dose CT scan optimized for rest-stress PET attenuation correction and quantification of coronary artery calcium
    Kaster, Tyler S.
    Dwivedi, Girish
    Susser, Leah
    Renaud, Jennifer M.
    Beanlands, Rob S. B.
    Chow, Benjamin J. W.
    deKemp, Robert A.
    JOURNAL OF NUCLEAR CARDIOLOGY, 2015, 22 (03) : 419 - 428
  • [40] Approaches to ultra-low radiation dose coronary artery calcium scoring based on 3rd generation dual-source CT: A phantom study
    McQuiston, Andrew D.
    Muscogiuri, Giuseppe
    Schoepf, U. Joseph
    Meinel, Felix G.
    Canstein, Christian
    Varga-Szemes, Akos
    Cannao, Paola M.
    Wichmann, Julian L.
    Allmendinger, Thomas
    Vliegenthart, Rozemarijn
    De Cecco, Carlo N.
    EUROPEAN JOURNAL OF RADIOLOGY, 2016, 85 (01) : 39 - 47