Performance of visual, manual, and automatic coronary calcium scoring of cardiac 13N-ammonia PET/low dose CT

被引:3
|
作者
Dobrolinska, Magdalena M. [1 ,2 ,3 ]
Lazarenko, Sergiy, V [4 ]
van der Zant, Friso M. [4 ]
Does, Lonneke [4 ]
van der Werf, Niels [5 ,6 ]
Prakken, Niek H. J. [1 ,2 ,3 ]
Greuter, Marcel J. W. [1 ,2 ,3 ,7 ]
Slart, Riemer H. J. A. [1 ,2 ,3 ,8 ]
Knol, Remco J. J. [4 ]
机构
[1] Univ Groningen, Univ Med Ctr Groningen, Med Imaging Ctr, Dept Radiol, NL-9700 RB Groningen, Netherlands
[2] Univ Groningen, Univ Med Ctr Groningen, Med Imaging Ctr, Dept Nucl Med, NL-9700 RB Groningen, Netherlands
[3] Univ Groningen, Univ Med Ctr Groningen, Med Imaging Ctr, Dept Mol Imaging, NL-9700 RB Groningen, Netherlands
[4] Northwest Clin, Dept Nucl Med, Alkmaar, Netherlands
[5] Univ Utrecht, Univ Med Ctr Utrecht, Dept Radiol, Utrecht, Netherlands
[6] Erasmus MC, Dept Radiol & Nucl Med, Rotterdam, Netherlands
[7] Univ Twente, Dept Robot & Mechatron, Fac Elect Engn Math & Comp Sci, Enschede, Netherlands
[8] Univ Twente, Fac Sci & Technol, Dept Biomed Photon Imaging, Enschede, Netherlands
关键词
CAD; PET; CT; Image interpretation; CARDIOVASCULAR COMPUTED-TOMOGRAPHY; 2016 SCCT/STR GUIDELINES; ARTERY CALCIUM; ATTENUATION CORRECTION; CALCIFICATION; DISEASE; SCANS; ATHEROSCLEROSIS; QUANTIFICATION; PREDICTION;
D O I
10.1007/s12350-022-03018-0
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Coronary artery calcium is a well-known predictor of major adverse cardiac events and is usually scored manually from dedicated, ECG-triggered calcium scoring CT (CSCT) scans. In clinical practice, a myocardial perfusion PET scan is accompanied by a non-ECG triggered low dose CT (LDCT) scan. In this study, we investigated the accuracy of patients' cardiovascular risk categorisation based on manual, visual, and automatic AI calcium scoring using the LDCT scan. Methods We retrospectively enrolled 213 patients. Each patient received a N-13-ammonia PET scan, an LDCT scan, and a CSCT scan as the gold standard. All LDCT and CSCT scans were scored manually, visually, and automatically. For the manual scoring, we used vendor recommended software (Syngo.via, Siemens). For visual scoring a 6-points risk scale was used (0; 1-10; 11-100; 101-400; 401-100; > 1 000 Agatston score). The automatic scoring was performed with deep learning software (Syngo.via, Siemens). All manual and automatic Agatston scores were converted to the 6-point risk scale. Manual CSCT scoring was used as a reference. Results The agreement of manual and automatic LDCT scoring with the reference was low [weighted kappa 0.59 (95% CI 0.53-0.65); 0.50 (95% CI 0.44-0.56), respectively], but the agreement of visual LDCT scoring was strong [0.82 (95% CI 0.77-0.86)]. Conclusions Compared with the gold standard manual CSCT scoring, visual LDCT scoring outperformed manual LDCT and automatic LDCT scoring.
引用
收藏
页码:239 / 250
页数:12
相关论文
共 43 条
  • [21] Automatic Coronary Calcium Scoring in Cardiac CT Angiography Using Convolutional Neural Networks
    Wolterink, Jelmer M.
    Leiner, Tim
    Viergever, Max A.
    Isgum, Ivana
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2015, PT I, 2015, 9349 : 589 - 596
  • [22] An evaluation of automatic coronary artery calcium scoring methods with cardiac CT using the orCaScore framework
    Wolterink, Jelmer M.
    Leiner, Tim
    de Vos, Bob D.
    Coatrieux, Jean-Louis
    Kelm, B. Michael
    Kondo, Satoshi
    Salgado, Rodrigo A.
    Shahzad, Rahil
    Shu, Huazhong
    Snoeren, Miranda
    Takx, Richard A. P.
    van Vliet, Lucas J.
    van Walsum, Theo
    Willems, Tineke P.
    Yang, Guanyu
    Zheng, Yefeng
    Viergever, Max A.
    Isgum, Ivana
    MEDICAL PHYSICS, 2016, 43 (05) : 2361 - 2373
  • [23] Regadenoson-induced hyperemia for absolute myocardial blood flow quantitation by 13N-ammonia PET and detection of cardiac allograft vasculopathy
    Packard, Rene R. Sevag
    Maddahi, Jamshid
    JOURNAL OF NUCLEAR CARDIOLOGY, 2017, 24 (04) : 1145 - 1148
  • [24] Automatic Calcium Scoring in Low-Dose Chest CT Using Deep Neural Networks With Dilated Convolutions
    Lessmann, Nikolas
    van Ginneken, Bram
    Zreik, Majd
    de Jong, Pim A.
    de Vos, Bob D.
    Viergever, Max A.
    Isgum, Ivana
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2018, 37 (02) : 615 - 625
  • [25] 13N-Ammonia PET/CT Detection of Myocardial Perfusion Abnormalities in Beagle Dogs After Local Heart Irradiation
    Song, Jianbo
    Yan, Rui
    Wu, Zhifang
    Li, Jianguo
    Yan, Min
    Hao, Xinzhong
    Liu, Jianzhong
    Li, Sijin
    JOURNAL OF NUCLEAR MEDICINE, 2017, 58 (04) : 605 - 610
  • [26] Low-dose coronary calcium scoring CT using a dedicated reconstruction filter for kV-independent calcium measurements
    Jubran, Ayman
    Mastrodicasa, Domenico
    van Praagh, Gijs D.
    Willemink, Martin J.
    Kino, Aya
    Wang, Jia
    Fleischmann, Dominik
    Nieman, Koen
    EUROPEAN RADIOLOGY, 2022, 32 (06) : 4225 - 4233
  • [27] Improved accuracy of the biodistribution and internal radiation dosimetry of 13N-ammonia using a total-body PET/CT scanner
    Yu, Xiaofeng
    Sun, Hongyan
    Xu, Lian
    Han, Yuan
    Wang, Cheng
    Li, Lianghua
    Ng, YeeLing
    Shi, Fuxiao
    Qiu, Ju
    Huang, Gang
    Zhou, Yun
    Chen, Yumei
    Liu, Jianjun
    MEDICAL PHYSICS, 2023, 50 (09) : 5865 - 5874
  • [28] Automatic coronary artery calcium scoring in cardiac CT angiography using paired convolutional neural networks
    Wolterink, Jelmer M.
    Leiner, Tim
    de Vos, Bob D.
    van Hamersvelt, Robbert W.
    Viergever, Max A.
    Isgum, Ivana
    MEDICAL IMAGE ANALYSIS, 2016, 34 : 123 - 136
  • [29] Reliability analysis of visual ranking of coronary artery calcification on low-dose CT of the thorax for lung cancer screening: comparison with ECG-gated calcium scoring CT
    Kim, Yoon Kyung
    Sung, Yon Mi
    Cho, So Hyun
    Park, Young Nam
    Choi, Hye-Young
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2014, 30 : 81 - 87
  • [30] Reliable categorisation of visual scoring of coronary artery calcification on low-dose CT for lung cancer screening: validation with the standard Agatston score
    Huang, Yi-Luan
    Wu, Fu-Zong
    Wang, Yen-Chi
    Ju, Yu-Jeng
    Mar, Guang-Yuan
    Chuo, Chiung-Chen
    Lin, Huey-Shyan
    Wu, Ming-Ting
    EUROPEAN RADIOLOGY, 2013, 23 (05) : 1226 - 1233