Performance of visual, manual, and automatic coronary calcium scoring of cardiac 13N-ammonia PET/low dose CT

被引:3
|
作者
Dobrolinska, Magdalena M. [1 ,2 ,3 ]
Lazarenko, Sergiy, V [4 ]
van der Zant, Friso M. [4 ]
Does, Lonneke [4 ]
van der Werf, Niels [5 ,6 ]
Prakken, Niek H. J. [1 ,2 ,3 ]
Greuter, Marcel J. W. [1 ,2 ,3 ,7 ]
Slart, Riemer H. J. A. [1 ,2 ,3 ,8 ]
Knol, Remco J. J. [4 ]
机构
[1] Univ Groningen, Univ Med Ctr Groningen, Med Imaging Ctr, Dept Radiol, NL-9700 RB Groningen, Netherlands
[2] Univ Groningen, Univ Med Ctr Groningen, Med Imaging Ctr, Dept Nucl Med, NL-9700 RB Groningen, Netherlands
[3] Univ Groningen, Univ Med Ctr Groningen, Med Imaging Ctr, Dept Mol Imaging, NL-9700 RB Groningen, Netherlands
[4] Northwest Clin, Dept Nucl Med, Alkmaar, Netherlands
[5] Univ Utrecht, Univ Med Ctr Utrecht, Dept Radiol, Utrecht, Netherlands
[6] Erasmus MC, Dept Radiol & Nucl Med, Rotterdam, Netherlands
[7] Univ Twente, Dept Robot & Mechatron, Fac Elect Engn Math & Comp Sci, Enschede, Netherlands
[8] Univ Twente, Fac Sci & Technol, Dept Biomed Photon Imaging, Enschede, Netherlands
关键词
CAD; PET; CT; Image interpretation; CARDIOVASCULAR COMPUTED-TOMOGRAPHY; 2016 SCCT/STR GUIDELINES; ARTERY CALCIUM; ATTENUATION CORRECTION; CALCIFICATION; DISEASE; SCANS; ATHEROSCLEROSIS; QUANTIFICATION; PREDICTION;
D O I
10.1007/s12350-022-03018-0
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Coronary artery calcium is a well-known predictor of major adverse cardiac events and is usually scored manually from dedicated, ECG-triggered calcium scoring CT (CSCT) scans. In clinical practice, a myocardial perfusion PET scan is accompanied by a non-ECG triggered low dose CT (LDCT) scan. In this study, we investigated the accuracy of patients' cardiovascular risk categorisation based on manual, visual, and automatic AI calcium scoring using the LDCT scan. Methods We retrospectively enrolled 213 patients. Each patient received a N-13-ammonia PET scan, an LDCT scan, and a CSCT scan as the gold standard. All LDCT and CSCT scans were scored manually, visually, and automatically. For the manual scoring, we used vendor recommended software (Syngo.via, Siemens). For visual scoring a 6-points risk scale was used (0; 1-10; 11-100; 101-400; 401-100; > 1 000 Agatston score). The automatic scoring was performed with deep learning software (Syngo.via, Siemens). All manual and automatic Agatston scores were converted to the 6-point risk scale. Manual CSCT scoring was used as a reference. Results The agreement of manual and automatic LDCT scoring with the reference was low [weighted kappa 0.59 (95% CI 0.53-0.65); 0.50 (95% CI 0.44-0.56), respectively], but the agreement of visual LDCT scoring was strong [0.82 (95% CI 0.77-0.86)]. Conclusions Compared with the gold standard manual CSCT scoring, visual LDCT scoring outperformed manual LDCT and automatic LDCT scoring.
引用
收藏
页码:239 / 250
页数:12
相关论文
共 43 条
  • [1] Performance of visual, manual, and automatic coronary calcium scoring of cardiac 13N-ammonia PET/low dose CT
    Magdalena M. Dobrolinska
    Sergiy V. Lazarenko
    Friso M. van der Zant
    Lonneke Does
    Niels van der Werf
    Niek H. J. Prakken
    Marcel J. W. Greuter
    Riemer H. J. A. Slart
    Remco J. J. Knol
    Journal of Nuclear Cardiology, 2023, 30 : 239 - 250
  • [2] Coronary calcium score scans for attenuation correction of quantitative PET/CT 13N-ammonia myocardial perfusion imaging
    Burkhard, Nina
    Herzog, Bernhard A.
    Husmann, Lars
    Pazhenkottil, Aju P.
    Burger, Irene A.
    Buechel, Ronny R.
    Valenta, Ines
    Wyss, Christophe A.
    Kaufmann, Philipp A.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2010, 37 (03) : 517 - 521
  • [3] The feasibility of low-dose CT protocols for coronary artery calcium scoring and PET attenuation correction in cardiac PET/CT
    Wu, Tung-Hsin
    Lu, Kun-Mu
    Wu, Nien-Yun
    Wang, Shyh-Jen
    Mok, Greta S. P.
    Yang, Bang-Hung
    Yang, Ching-Ching
    NUCLEAR MEDICINE COMMUNICATIONS, 2015, 36 (04) : 376 - 385
  • [4] Direct Automatic Coronary Calcium Scoring in Cardiac and Chest CT
    de Vos, Bob D.
    Wolterink, Jelmer M.
    Leiner, Tim
    de Jong, Pim A.
    Lessmann, Nikolas
    Isgum, Ivana
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2019, 38 (09) : 2127 - 2138
  • [5] Coronary calcium scoring of CT attenuation correction scans: Automatic, manual, or visual?
    Dumeer, Shifali
    Einstein, Andrew J.
    JOURNAL OF NUCLEAR CARDIOLOGY, 2018, 25 (06) : 2144 - 2147
  • [6] Coronary calcium score scans for attenuation correction of quantitative PET/CT 13N-ammonia myocardial perfusion imaging
    Nina Burkhard
    Bernhard A. Herzog
    Lars Husmann
    Aju P. Pazhenkottil
    Irene A. Burger
    Ronny R. Buechel
    Ines Valenta
    Christophe A. Wyss
    Philipp A. Kaufmann
    European Journal of Nuclear Medicine and Molecular Imaging, 2010, 37 : 517 - 521
  • [7] The prognostic value of visual and automatic coronary calcium scoring from low-dose computed tomography-[15O]-water positron emission tomography
    Dobrolinska, M. M.
    Jukema, R. A.
    van Velzen, S. G. M.
    van Diemen, P. A.
    Greuter, M. J. W.
    Prakken, N. H. J.
    van der Werf, N. R.
    Raijmakers, P. G.
    Slart, R. H. J. A.
    Knaapen, P.
    Isgum, I.
    Danad, I
    EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2024, 25 (09) : 1186 - 1196
  • [8] Fully automatic coronary calcium scoring in non-ECG-gated low-dose chest CT: comparison with ECG-gated cardiac CT
    Suh, Young Joo
    Kim, Cherry
    Lee, June-Goo
    Oh, Hongmin
    Kang, Heejun
    Kim, Young-Hak
    Yang, Dong Hyun
    EUROPEAN RADIOLOGY, 2023, 33 (02) : 1254 - 1265
  • [9] Deep convolutional neural networks for automatic coronary calcium scoring in a screening study with low-dose chest CT
    Lessmann, Nikolas
    Isgum, Ivana
    Setio, Arnaud A. A.
    de Vos, Bob D.
    Ciompi, Francesco
    de Jong, Pim A.
    Oudkerk, Matthijs
    Mali, Willem P. Th. M.
    Viergever, Max A.
    van Ginneken, Bram
    MEDICAL IMAGING 2016: COMPUTER-AIDED DIAGNOSIS, 2015, 9785
  • [10] 13N-ammonia PET/CT stress myocardial blood flow compared to fractional flow reserve in coronary artery disease
    Boer, Jouke J.
    Kappelhof, Johan J. J. S.
    van der Zant, Friso M.
    Wondergem, Maurits
    de Swart, Hans J. B. R. M.
    Knol, Remco J. J.
    NUCLEAR MEDICINE COMMUNICATIONS, 2020, 41 (02) : 133 - 138