Seismic behavior of partially encased composite columns-steel plate shear wall structure with different semi-rigid joints

被引:6
作者
Yu, Jinguang [1 ,2 ]
Zhao, Chu [1 ]
Zhong, Weihui [1 ,2 ]
机构
[1] Xian Univ Architecture & Technol, Sch Civil Engn, Xian 710055, Peoples R China
[2] Collaborat Innovat Ctr Assembled Bldg Western Chin, Xian 710055, Peoples R China
基金
中国国家自然科学基金;
关键词
Steel plate shear wall; PEC column; Component method; Seismic performance; Semi-rigid connection; PERFORMANCE; MODEL;
D O I
10.1016/j.jobe.2023.108177
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Seismic performance of partially encased concrete (PEC) column-steel plate shear wall (SPSW) structure is significantly affected by the characteristics of beam-column connections. Three component models of semi-rigid beam-column connections, including the bidirectional bolt extended end-plate connection, the flush end-plate connection, and the web double-angle steel connection, are designed according to Eurocode 3. Afterward, three 1/3-scale two-story singlespan PEC column-SPSW structures with the three types of semi-rigid connections are tested under quasi-static cyclic loading. The test results indicate that all three structures satisfy the design requirement of "strong frame-weak wall plate". The PEC-SPSW structure with the bidirectional bolt extended end-plate connections exhibits a higher bearing capacity and stiffness than the other two structures. Compared with the web double-angle connection, the adoption of bidirec-tional bolt extended end-plate connection increases the yield bearing capacity by 14.32% and the initial stiffness by 16.16%, but ductility decreases by 17.65%. The energy dissipation of each story of the structure with flush end-plate connections is relatively balanced. The energy dissipated by the second-story of SPSW is less than that of its first-story due to the higher rotational stiffness of the bidirectional bolt extended end-plate connections. The PEC-SPSW structures fracture at the column foot. The reliability of the initial rotational stiffness component models is verified by comparing the finite element (FE) and test results.
引用
收藏
页数:20
相关论文
共 35 条
[1]   Development of moment-rotation model equations for flush end-plate connections [J].
Abolmaali, A ;
Matthys, JH ;
Farooqi, M ;
Choi, Y .
JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2005, 61 (12) :1595-1612
[2]   Numerical study of top-and seat-angle with double web-angle connection with high-strength steel [J].
AlHendi, H. ;
Mahmoud, M. ;
Celikag, M. .
JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2020, 174
[3]   Experimental and numerical investigations on cyclic performance of L-shaped-CFT column frame-buckling restrained and unrestrained steel plate shear walls with partial double-side/four corner connections [J].
Amer, Mohammed ;
Chen, Zhihua ;
Du, Yansheng ;
Mashrah, W. A. H. ;
Zhang, Wang .
JOURNAL OF BUILDING ENGINEERING, 2023, 78
[4]  
[Anonymous], 2005, EUROCODE 3 DESIGN ST
[5]   Flexibility requirement of bolted double-angle shear connections [J].
Arjomandi, Kaveh ;
Matthews, Josiah ;
Wyman, Brett .
JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2021, 184
[6]   Experimental and numerical investigation of low-yield-strength (LYS) steel plate shear walls under cyclic loading [J].
Azandariani, Mojtaba Gorji ;
Gholhaki, Majid ;
Kafi, Mohammad Ali .
ENGINEERING STRUCTURES, 2020, 203
[7]   The response of flush end-plate joints under earthquake loading [J].
Broderick, BM ;
Thomson, AW .
JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2002, 58 (09) :1161-1175
[8]  
Chinese Industry Standard, 2015, JGJ/T 101-2015
[9]  
Chinese Industry Standard, 2009, CECS 260-2009
[10]  
Chinese Industry Standard, 2015, JGJ/T 380-2015