Thermal performance of a single loop pulsating heat pipe with asymmetric adiabatic channel

被引:14
|
作者
Patel, Est Dev [1 ]
Kumar, Subrata [1 ]
机构
[1] Inst Technol Patna, Mech Engn, Patna 801106, Bihar, India
关键词
Two-phase flow; Pulsating heat pipe; Thermal management; pressure oscillations; EVACUATION PRESSURE; DESIGN; RATIOS;
D O I
10.1016/j.applthermaleng.2022.119541
中图分类号
O414.1 [热力学];
学科分类号
摘要
The thermal performance of an asymmetric single-turn closed-loop pulsating heat pipe (aCLPHP) has been investigated experimentally. In an asymmetric closed-loop, the working fluids may exhibit a consistent two-phase oscillatory-circulatory flow as a direct consequence of the capillary pressure difference. The adiabatic channels of different cross-sections will cause a pressure difference, boosting the flow of heated vapor and liquid. So, a novel aCLPHP of 208 mm with an evaporator of 35 mm length was fabricated from 2.4 and 3.4 mm inner diameter copper capillary tubes. The setup was subjected to gradual and abrupt heat loads (in vertical bottom heating mode) to find out the effects of inclination angles (0 degrees, 30 degrees, 60 degrees, and 90 degrees), working fluids, and filling ratios (FR) on the thermal performance. A constant supply of coolant in the condenser chamber through a bath assisted in dissipating the heat from the heat pipe. The simultaneous temperature and pressure signals at 10 Hz were recorded through a data acquisition system to analyze the thermal performance and flow characteristics. The average thermal resistance is mapped to different operating conditions to compare the conventional (uniform cross-section) and asymmetric adiabatic channel configurations. The pseudo-steady state operation was obtained up to 100 W power supply at 60% FR of pure water in the vertical orientation. Due to asymmetry, the heat carrying capacity was increased by 75% and 50% for working fluid water and acetone, respectively. The heat pipe was operating at lower inclination angles, except horizontal orientation only with pure water. Hence, introducing an asymmetric adiabatic section is a simple, reliable, and cost-effective approach to improve the capability of a single-turn CLPHP for the thermal management of various electronic components.
引用
收藏
页数:13
相关论文
共 50 条
  • [41] Numerical study of the thermal performance of a hydrogen pulsating heat pipe
    Sun, Xiao
    Li, Sizhuo
    Wang, Bo
    Jiao, Bo
    Pfotenhauer, John
    Miller, Franklin
    Gan, Zhihua
    INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2022, 172
  • [42] EFFECT OF WORKING FLUID ON PULSATING HEAT PIPE THERMAL PERFORMANCE
    Fumoto, Koji
    Kawaji, Masahiro
    Kawanami, Tsuyoshi
    PROCEEDINGS OF THE ASME INTERNATIONAL HEAT TRANSFER CONFERENCE - 2010, VOL 5: FUEL CELLS, GAS TURBINES, HEAT PIPES, JET IMPINGEMENT, RADIATION, 2010, : 393 - 399
  • [43] The combined effects of filling ratio and inclination angle on thermal performance of a closed loop pulsating heat pipe
    Markal, Burak
    Aksoy, Kubra
    HEAT AND MASS TRANSFER, 2021, 57 (05) : 751 - 763
  • [44] A study on thermal performance of parallel connected pulsating heat pipe
    Kim, Byeongchan
    Li, Longnan
    Kim, Jihoon
    Kim, Daejoong
    APPLIED THERMAL ENGINEERING, 2017, 126 : 1063 - 1068
  • [45] Numerical study of a novel Single-loop pulsating heat pipe with separating walls within the flow channel
    Kang, Zhanxiao
    Shou, Dahua
    Fan, Jintu
    APPLIED THERMAL ENGINEERING, 2021, 196
  • [46] Experimental Study of Thermal Performance of Pulsating-Heat-Pipe Heat Exchanger with Asymmetric Structure at Different Filling Rates
    Liu, Jianhong
    Liu, Dong
    Shang, Fumin
    Yang, Kai
    Zheng, Chaofan
    Cao, Xin
    ENERGIES, 2024, 17 (15)
  • [47] Closed-loop pulsating heat pipe
    Tong, BY
    Wong, TN
    Ooi, KT
    APPLIED THERMAL ENGINEERING, 2001, 21 (18) : 1845 - 1862
  • [48] Experimental Investigations on the Thermal Performance of a Vertical Closed Loop Pulsating Heat Pipe Using Binary Mixture of Fluids
    Pradeep, G. V.
    Narasimha, K. Rama
    INTERNATIONAL JOURNAL OF ENGINEERING, 2018, 31 (05): : 805 - 811
  • [49] Influence of Al2O3 Nanoparticles on Thermal Performance of Closed Loop Pulsating Heat Pipe
    Babu, E. R.
    Reddy, Nagaraja C.
    Reddappa, H. N.
    Murthy, K. V. Shivananda
    Reddy, G. V. Gnanendra
    Koppad, P. G.
    FME TRANSACTIONS, 2020, 48 (01): : 143 - 148
  • [50] Thermal performance of concentrically arranged two interconnected single-loop pulsating heat pipes
    Patel, Est Dev
    Shukla, Anoop Kumar
    Kumar, Subrata
    ENERGY CONVERSION AND MANAGEMENT, 2025, 323