Thermal performance of a single loop pulsating heat pipe with asymmetric adiabatic channel

被引:14
|
作者
Patel, Est Dev [1 ]
Kumar, Subrata [1 ]
机构
[1] Inst Technol Patna, Mech Engn, Patna 801106, Bihar, India
关键词
Two-phase flow; Pulsating heat pipe; Thermal management; pressure oscillations; EVACUATION PRESSURE; DESIGN; RATIOS;
D O I
10.1016/j.applthermaleng.2022.119541
中图分类号
O414.1 [热力学];
学科分类号
摘要
The thermal performance of an asymmetric single-turn closed-loop pulsating heat pipe (aCLPHP) has been investigated experimentally. In an asymmetric closed-loop, the working fluids may exhibit a consistent two-phase oscillatory-circulatory flow as a direct consequence of the capillary pressure difference. The adiabatic channels of different cross-sections will cause a pressure difference, boosting the flow of heated vapor and liquid. So, a novel aCLPHP of 208 mm with an evaporator of 35 mm length was fabricated from 2.4 and 3.4 mm inner diameter copper capillary tubes. The setup was subjected to gradual and abrupt heat loads (in vertical bottom heating mode) to find out the effects of inclination angles (0 degrees, 30 degrees, 60 degrees, and 90 degrees), working fluids, and filling ratios (FR) on the thermal performance. A constant supply of coolant in the condenser chamber through a bath assisted in dissipating the heat from the heat pipe. The simultaneous temperature and pressure signals at 10 Hz were recorded through a data acquisition system to analyze the thermal performance and flow characteristics. The average thermal resistance is mapped to different operating conditions to compare the conventional (uniform cross-section) and asymmetric adiabatic channel configurations. The pseudo-steady state operation was obtained up to 100 W power supply at 60% FR of pure water in the vertical orientation. Due to asymmetry, the heat carrying capacity was increased by 75% and 50% for working fluid water and acetone, respectively. The heat pipe was operating at lower inclination angles, except horizontal orientation only with pure water. Hence, introducing an asymmetric adiabatic section is a simple, reliable, and cost-effective approach to improve the capability of a single-turn CLPHP for the thermal management of various electronic components.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] A Capillary Tube Pulsating Heat Pipe With Asymmetric Adiabatic Channels for Thermal Management
    Patel, Est Dev
    Kumar, Subrata
    IEEE TRANSACTIONS ON COMPONENTS PACKAGING AND MANUFACTURING TECHNOLOGY, 2022, 12 (11): : 1791 - 1798
  • [2] Thermal performance of an open loop closed end pulsating heat pipe
    Manabendra Saha
    C. M. Feroz
    F. Ahmed
    T. Mujib
    Heat and Mass Transfer, 2012, 48 : 259 - 265
  • [3] Parametric Characterization on the Thermal Performance of a Closed Loop Pulsating Heat Pipe
    Rao, C. Sreenivasa
    Gupta, A.
    Narasimha, K. Rama
    JOURNAL OF APPLIED FLUID MECHANICS, 2016, 9 (02) : 615 - 624
  • [4] Effect of nanofluids on thermal performance of closed loop pulsating heat pipe
    Karthikeyan, V. K.
    Ramachandran, K.
    Pillai, B. C.
    Solomon, A. Brusly
    EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2014, 54 : 171 - 178
  • [5] EXPERIMENTAL INVESTIGATIONS ON THERMAL PERFORMANCE OF A CLOSED LOOP PULSATING HEAT PIPE
    Wang, Yu
    Li, Weiyi
    Wei, Lianyou
    Cao, Binbin
    PROCEEDINGS OF THE ASME MICRO/NANOSCALE HEAT AND MASS TRANSFER INTERNATIONAL CONFERENCE, VOL 3, 2010, : 295 - 303
  • [6] Thermal performance of an open loop closed end pulsating heat pipe
    Saha, Manabendra
    Feroz, C. M.
    Ahmed, F.
    Mujib, T.
    HEAT AND MASS TRANSFER, 2012, 48 (02) : 259 - 265
  • [7] Thermal Performance of a Closed-Loop Pulsating Heat Pipe With Multiple Heat Sources
    Kammuang-Lue, Niti
    Sakulchangsatjatai, Phrut
    Terdtoon, Pradit
    HEAT TRANSFER ENGINEERING, 2014, 35 (13) : 1161 - 1172
  • [8] Effect of Working Fluids on Thermal Performance of Closed Loop Pulsating Heat Pipe
    Kolkova, Zuzana
    Malcho, Milan
    XIX.THE APPLICATION OF EXPERIMENTAL AND NUMERICAL METHODS IN FLUID MECHANICS AND ENERGETICS 2014, 2014, 1608 : 128 - 131
  • [9] EFFECT OF INCLINATION ANGLE ON THE CLOSED LOOP PULSATING HEAT PIPE THERMAL PERFORMANCE
    Pachghare, Pramod R.
    Mahalle, Ashish M.
    PROCEEDINGS OF THE ASME SUMMER HEAT TRANSFER CONFERENCE - 2013, VOL 2, 2014,
  • [10] Effect of Filling Ratio on Thermal Performance of Closed Loop Pulsating Heat Pipe
    Babu, E. R.
    Reddappa, H. N.
    Reddy, G. V. Gnanendra
    MATERIALS TODAY-PROCEEDINGS, 2018, 5 (10) : 22229 - 22236