Thermal performance of a single loop pulsating heat pipe with asymmetric adiabatic channel

被引:15
作者
Patel, Est Dev [1 ]
Kumar, Subrata [1 ]
机构
[1] Inst Technol Patna, Mech Engn, Patna 801106, Bihar, India
关键词
Two-phase flow; Pulsating heat pipe; Thermal management; pressure oscillations; EVACUATION PRESSURE; DESIGN; RATIOS;
D O I
10.1016/j.applthermaleng.2022.119541
中图分类号
O414.1 [热力学];
学科分类号
摘要
The thermal performance of an asymmetric single-turn closed-loop pulsating heat pipe (aCLPHP) has been investigated experimentally. In an asymmetric closed-loop, the working fluids may exhibit a consistent two-phase oscillatory-circulatory flow as a direct consequence of the capillary pressure difference. The adiabatic channels of different cross-sections will cause a pressure difference, boosting the flow of heated vapor and liquid. So, a novel aCLPHP of 208 mm with an evaporator of 35 mm length was fabricated from 2.4 and 3.4 mm inner diameter copper capillary tubes. The setup was subjected to gradual and abrupt heat loads (in vertical bottom heating mode) to find out the effects of inclination angles (0 degrees, 30 degrees, 60 degrees, and 90 degrees), working fluids, and filling ratios (FR) on the thermal performance. A constant supply of coolant in the condenser chamber through a bath assisted in dissipating the heat from the heat pipe. The simultaneous temperature and pressure signals at 10 Hz were recorded through a data acquisition system to analyze the thermal performance and flow characteristics. The average thermal resistance is mapped to different operating conditions to compare the conventional (uniform cross-section) and asymmetric adiabatic channel configurations. The pseudo-steady state operation was obtained up to 100 W power supply at 60% FR of pure water in the vertical orientation. Due to asymmetry, the heat carrying capacity was increased by 75% and 50% for working fluid water and acetone, respectively. The heat pipe was operating at lower inclination angles, except horizontal orientation only with pure water. Hence, introducing an asymmetric adiabatic section is a simple, reliable, and cost-effective approach to improve the capability of a single-turn CLPHP for the thermal management of various electronic components.
引用
收藏
页数:13
相关论文
共 30 条
  • [1] Analysis of thermally driven flow behaviors for two-turn closed-loop pulsating heat pipe in ambient conditions: An experimental approach
    Ahmad, Hibal
    Kim, Seong Kuen
    Jung, Sung Yong
    [J]. INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2020, 150
  • [2] Akachi H., 1990, STRUCTURE HEAT PIPE
  • [3] A novel design of pulsating heat pipe with fewer turns applicable to all orientations
    Chien, Kuo-Hsiang
    Lin, Yur-Tsai
    Chen, Yi-Rong
    Yang, Kai-Shing
    Wang, Chi-Chuan
    [J]. INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2012, 55 (21-22) : 5722 - 5728
  • [4] Heat transfer performance of closed loop pulsating heat pipes with methanol-based binary mixtures
    Cui, Xiaoyu
    Qiu, Ziqian
    Weng, Jianhua
    Li, Zhihua
    [J]. EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2016, 76 : 253 - 263
  • [5] Combination study of operation characteristics and heat transfer mechanism for pulsating heat pipe
    Cui, Xiaoyu
    Zhu, Yue
    Li, Zhihua
    Shun, Shende
    [J]. APPLIED THERMAL ENGINEERING, 2014, 65 (1-2) : 394 - 402
  • [6] Design and operation of a Tesla-type valve for pulsating heat pipes
    de Vries, S. F.
    Florea, D.
    Homburg, F. G. A.
    Frijns, A. J. H.
    [J]. INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2017, 105 : 1 - 11
  • [7] Experimental investigation of the thermal management of flat-plate closed-loop pulsating heat pipes with interconnecting channels
    Ebrahimi, M.
    Shafii, M. B.
    Bijarchi, M. A.
    [J]. APPLIED THERMAL ENGINEERING, 2015, 90 : 838 - 847
  • [8] Heat transfer characteristics of a novel closed-loop pulsating heat pipe with a check valve
    Feng, Chen
    Wan, Zhenping
    Mo, Haijun
    Tang, Heng
    Lu, Longsheng
    Tang, Yong
    [J]. APPLIED THERMAL ENGINEERING, 2018, 141 : 558 - 564
  • [9] Flow patterns and heat transfer characteristics of flat plate pulsating heat pipes with various asymmetric and aspect ratios of the channels
    Jang, Dong Soo
    Lee, Joo Seong
    Ahn, Jae Hwan
    Kim, Dongwoo
    Kim, Yongchan
    [J]. APPLIED THERMAL ENGINEERING, 2017, 114 : 211 - 220
  • [10] An insight into thermo-hydrodynamic coupling in closed loop pulsating heat pipes
    Khandekar, S
    Groll, M
    [J]. INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2004, 43 (01) : 13 - 20