Quantitative microbolometer-based thermoelastic stress analysis

被引:6
作者
Jimenez-Fortunato, Irene [1 ]
Bull, Daniel J. [1 ]
Thomsen, Ole T. [2 ]
Dulieu-Barton, Janice M. [2 ]
机构
[1] Univ Southampton, Sch Engn, Southampton, Hants, England
[2] Univ Bristol, Bristol Composites Inst, Bristol, Avon, England
基金
英国工程与自然科学研究理事会;
关键词
Infrared cameras; Thermoelastic stress analysis; Microbolometers; THERMOGRAPHY;
D O I
10.1016/j.optlaseng.2022.107276
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
The use of microbolometers for Thermoelastic Stress Analysis (TSA) has the potential of substantially reducing deployment costs, as well as providing more compact and lightweight solutions in comparison to more costly, bulky and less rugged photon detector based infrared cameras. However, microbolometer performance in terms of response time and sensitivity is less than what can be achieved with photon detectors. As the use of mi-crobolometers for TSA is becoming more widespread, it is timely to devise a means of assessing microbolometer performance and identifying the limitations of using such a system for TSA. A simulation approach is devised that enables the effect of the microbolometer response time on transient signals (such as that from TSA) to be investigated. As the TSA involves measuring a small transient temperature change, usually induced by sinusoidal cyclic loading, the simulation approach also includes the effect of a noisy non-sinusoidal signal. To identify any deleterious effects cause by a cyclic load, the transient temperature change is also generated using an optical chopper and a black body source. The variables studied are the Signal-to-Noise Ratio (SNR), the impact of dif-ferent waveforms, variation in the signal mean, as well as in-built system features such as the noise reduction. A new experimentally validated calibration approach is presented that accounts for the microbolometer response time and rolling averages introduced by inbuilt noise reduction features. It is shown the calibration approach is independent of specimen material and camera frame rates, and it is demonstrated on a CFRP test specimen containing a hidden crack.
引用
收藏
页数:16
相关论文
共 33 条
[1]  
Agarwal A, 2005, 1 ORDER TRANSIENT LI
[2]   Thermoelastic Stress Analysis of a Finite Orthotropic Composite Containing an Elliptical Hole [J].
Alshaya, A. ;
Shual, X. ;
Rowlands, R. .
EXPERIMENTAL MECHANICS, 2016, 56 (08) :1373-1384
[3]  
[Anonymous], 2016, TOUGHENED EPOXY PREP
[4]  
Budzier H, 2006, 9 INT C INFRARED SEN
[5]  
Budzier H. G., 2011, THERMAL INFRARED SEN
[6]  
DISTEK Measuring Instruments, FLIR SC5200 SC5500 S
[7]   Thermoelastic Stress Analysis and Digital Image Correlation to Assess Composites [J].
Dulieu-Barton, J. M. ;
Battams, G. P. .
MECHANICS OF COMPOSITE AND MULTI-FUNCTIONAL MATERIALS, VOL 7, 2017,
[8]  
Dulieu-Barton JM, 2012, Optical methods for solid mechanics
[9]  
Dulieu-Smith J. M., 1995, Strain, V31, P9, DOI 10.1111/j.1475-1305.1995.tb00949.x
[10]   A generalised approach to the calibration of orthotropic materials for thermoelastic stress analysis [J].
Emery, T. R. ;
Dulieu-Barton, J. M. ;
Earl, J. S. ;
Cunningham, P. R. .
COMPOSITES SCIENCE AND TECHNOLOGY, 2008, 68 (3-4) :743-752