Amorphous silica fiber matrix biomaterials: An analysis of material synthesis and characterization for tissue engineering

被引:15
作者
Kim, Hyun S. [1 ]
Kumbar, Sangamesh G. [1 ,2 ,3 ]
Nukavarapu, Syam P. [1 ,2 ,3 ]
机构
[1] Univ Connecticut, Dept Biomed Engn, Storrs, CT 06269 USA
[2] Univ Connecticut, Dept Mat Sci & Engn, Storrs, CT USA
[3] Univ Connecticut Hlth, Dept Orthopaed Surg, Farmington, CT USA
基金
美国国家卫生研究院; 美国国家科学基金会;
关键词
Silica biomaterial; Porous matrix; ECM-Like fibrous structure; Biodegradable; Water absorption; THERMAL-DECOMPOSITION; IN-VITRO; HYDROLYTIC DEGRADATION; MECHANICAL-PROPERTIES; ALIPHATIC POLYESTERS; HUMAN OSTEOBLASTS; GLASS COMPOSITE; IONIC PRODUCTS; SCAFFOLDS; HYDROGEL;
D O I
10.1016/j.bioactmat.2022.04.002
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Silica biomaterials including Bioglass offer great biocompatibility and bioactivity but fail to provide pore and degradation features needed for tissue engineering. Herein we report on the synthesis and characterization of novel amorphous silica fiber matrices to overcome these limitations. Amorphous silica fibers were fused by sintering to produce porous matrices. The effects of sacrificial polymer additives such as polyvinyl alcohol (PVA) and cellulose fibers (CF) on the sintering process were also studied. The resulting matrices formed between sintering temperatures of 1,350-1,550 degrees C retained their fiber structures. The matrices presented pores in the range of 50-200 mu m while higher sintering temperatures resulted in increased pore diameter. PVA addition to silica significantly reduced the pore diameter and porosity compared with silica matrices with or without the addition of CF. The PVA additive morphologically appeared to fuse the silica fibers to a greater extent and resulted in significantly higher compressive modulus and strength than the rest of the matrices synthesized. These matrices lost roughly 30% of their original mass in an in vitro degradation study over 40 weeks. All matrices absorbed 500 wt% of water and did not change in their overall morphology, size, or shape with hydration. These fiber matrices supported human mesenchymal stem cell adhesion, proliferation, and mineralized matrix production. Amorphous silica fiber biomaterials/matrices reported here are biodegradable and porous and closely resemble the native extracellular matrix structure and water absorption capacity. Extending the methodology reported here to alter matrix properties may lead to a variety of tissue engineering, implant, and drug delivery applications.
引用
收藏
页码:155 / 166
页数:12
相关论文
共 67 条
[1]   Oxygen-Tension Controlled Matrices for Enhanced Osteogenic Cell Survival and Performance [J].
Amini, A. R. ;
Nukavarapu, S. P. .
ANNALS OF BIOMEDICAL ENGINEERING, 2014, 42 (06) :1261-1270
[2]  
Amini AR, 2016, TISSUE ENG PT A, V22, P610, DOI [10.1089/ten.TEA.2015.0310, 10.1089/ten.tea.2015.0310]
[3]  
Amini Ami R, 2011, J Long Term Eff Med Implants, V21, P93
[4]   Biodegradation and biocompatibility of PLA and PLGA microspheres [J].
Anderson, James M. ;
Shive, Matthew S. .
ADVANCED DRUG DELIVERY REVIEWS, 2012, 64 :72-82
[5]   CALCIUM-PHOSPHATE FORMATION AT THE SURFACE OF BIOACTIVE GLASS INVIVO [J].
ANDERSSON, OH ;
KARLSSON, KH ;
KANGASNIEMI, K .
JOURNAL OF NON-CRYSTALLINE SOLIDS, 1990, 119 (03) :290-296
[6]  
Annabi N, 2010, TISSUE ENG PART B-RE, V16, P371, DOI [10.1089/ten.teb.2009.0639, 10.1089/ten.TEB.2009.0639]
[7]  
[Anonymous], 2012, D69515 ASTM INT
[8]   Sol-gel silica-based biomaterials and bone tissue regeneration [J].
Arcos, Daniel ;
Vallet-Regi, Maria .
ACTA BIOMATERIALIA, 2010, 6 (08) :2874-2888
[9]   Analysis of the in vitro degradation and the in vivo tissue response to bi-layered 3D-printed scaffolds combining PLA and biphasic PLA/bioglass components - Guidance of the inflammatory response as basis for osteochondral regeneration [J].
Barbeck, Mike ;
Serra, Tiziano ;
Booms, Patrick ;
Stojanovic, Sanja ;
Najman, Stevo ;
Engel, Elisabeth ;
Sader, Robert ;
Kirkpatrick, Charles James ;
Navarro, Melba ;
Ghanaati, Shahram .
BIOACTIVE MATERIALS, 2017, 2 (04) :208-223
[10]   Long-term in vitro degradation of PDLLA/Bioglass® bone scaffolds in acellular simulated body fluid [J].
Blaker, J. J. ;
Nazhat, S. N. ;
Maquet, V. ;
Boccaccini, A. R. .
ACTA BIOMATERIALIA, 2011, 7 (02) :829-840