Classification of hemoglobin fractions in the liquid state using Raman spectroscopy combined with machine learning

被引:10
作者
Abbasi, Sara [1 ]
Feizpour, Mehdi [1 ]
Weets, Ilse [2 ]
Liu, Qing [3 ,4 ]
Thienpont, Hugo [3 ,4 ]
Ferranti, Francesco [3 ,4 ]
Ottevaere, Heidi [3 ,4 ]
机构
[1] Vrije Univ Brussel, Dept Appl Phys & Photon, Brussels Photon, Pleinlaan 2, B-1050 Brussels, Belgium
[2] Vrije Univ Brussel, Univ Ziekenhuis Brussel, Dept Clin Biol, Res Grp Expt Pharmacol, Laarbeeklaan 101, B-1090 Brussels, Belgium
[3] Vrije Univ Brussel, Pleinlaan 2, B-1050 Brussels, Belgium
[4] Flanders Make, Dept Appl Phys & Photon, Brussels Photon, Pleinlaan 2, B-1050 Brussels, Belgium
关键词
Hemoglobin variants; Biosensors; Raman spectroscopy; Point -of -care testing; High -Performance Liquid Chromatography; (HPLC); Microfluidics; Clinical management; Machine learning optimization; HBA1C;
D O I
10.1016/j.microc.2023.109305
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Identifying hemoglobinopathies is important for the clinical management of many diseases. One of the common techniques to screen hemoglobinopathies is through high-performance liquid chromatography separation followed by UV-VIS detection. Although UV-VIS can quantify the hemoglobin fractions, it is unable to identify them. Here, we use Raman microscopy to generate fingerprint spectra of hemoglobin fractions based on which the fractions can be identified. Five different hemoglobin types are investigated in their liquid state: HbA0, HbS, HbF, HbA1c, and HbA2. Machine learning models based on support vector machines and fully-connected neural networks are optimized to classify these fractions achieving 98.2 & PLUSMN; 0.1% and 98.5 & PLUSMN; 0.3% test F1-score, respectively. In addition, the test accuracy of these two models are 98.2 & PLUSMN; 0.1% and 98.5 & PLUSMN; 0.3%, respectively. Our approach demonstrates the potential of Raman spectroscopy as an identification module in combination with high-performance liquid chromatography. Moreover, this detection approach can be easily miniaturized and integrated with microfluidics.
引用
收藏
页数:7
相关论文
共 45 条
[1]  
[Anonymous], 2011, Use of Glycated Haemoglobin (HbA1c) in the Diagnosis of Diabetes Mellitus: Abbreviated Report of a WHO Consultation
[2]   Raman Spectroscopy-Based Sensitive and Specific Detection of Glycated Hemoglobin [J].
Barman, Ishan ;
Dingari, Narahara Chari ;
Kang, Jeon Woong ;
Horowitz, Gary L. ;
Dasari, Ramachandra R. ;
Feld, Michael S. .
ANALYTICAL CHEMISTRY, 2012, 84 (05) :2474-2482
[3]   Detection of the sickle hemoglobin allele using a surface plasmon resonance based biosensor [J].
Breveglieri, Giulia ;
D'Aversa, Elisabetta ;
Cosenza, Lucia Carmela ;
Boutou, Effrossyni ;
Balassopoulou, Angeliki ;
Voskaridou, Ersi ;
Gambari, Roberto ;
Borgatti, Monica .
SENSORS AND ACTUATORS B-CHEMICAL, 2019, 296
[4]   Raman spectroscopy for a rapid diagnosis of sickle cell disease in human blood samples: a preliminary study [J].
Bueno Filho, Antonio Carlos ;
Silveira, Landulfo, Jr. ;
Yanai, Ana Leticia Sant'Anna ;
Fernandes, Adriana Barrinha .
LASERS IN MEDICAL SCIENCE, 2015, 30 (01) :247-253
[5]   A comparative study of HPLC and UV spectrophotometric methods for remdesivir quantification in pharmaceutical formulations [J].
Bulduk, Ibrahim ;
Akbel, Erten .
JOURNAL OF TAIBAH UNIVERSITY FOR SCIENCE, 2021, 15 (01) :507-513
[6]   LIBSVM: A Library for Support Vector Machines [J].
Chang, Chih-Chung ;
Lin, Chih-Jen .
ACM TRANSACTIONS ON INTELLIGENT SYSTEMS AND TECHNOLOGY, 2011, 2 (03)
[7]  
Christopher M., 2006, Pattern Recognition and Machine Learning, VBishop, P183
[8]  
Clarke GM, 2000, CLIN CHEM, V46, P1284
[9]   ROBUST LOCALLY WEIGHTED REGRESSION AND SMOOTHING SCATTERPLOTS [J].
CLEVELAND, WS .
JOURNAL OF THE AMERICAN STATISTICAL ASSOCIATION, 1979, 74 (368) :829-836
[10]   Diagnosing sickle cell disease and iron deficiency anemia in human blood by Raman spectroscopy [J].
da Silva, Wagner Rafael ;
Silveira Jr, Landulfo ;
Fernandes, Adriana Barrinha .
LASERS IN MEDICAL SCIENCE, 2020, 35 (05) :1065-1074