Measurement of Stroke Volume With Echocardiography Compared to Gold Standard Cardiac Magnetic Resonance Imaging: An Observational Study

被引:4
|
作者
Cowie, Brian [1 ,2 ,3 ,4 ]
Wright, Leah [2 ]
Costello, Ben [2 ]
Janssens, Kristel [2 ]
Howden, Erin [2 ]
Flannery, Darragh [2 ]
Foulkes, Steve [2 ]
Kluger, Roman [1 ,3 ]
La Gerche, Andre [2 ]
机构
[1] St Vincents Hosp, Dept Anaesthesia, Melbourne, Australia
[2] Baker Heart & Diabet Inst, Sports Cardiol, Melbourne, Australia
[3] Univ Melbourne, Dept Crit Care, Melbourne, Australia
[4] St Vincents Hosp, Dept Anaesthesia & Acute Pain Med, 45 Victoria Parade, Fitzroy 3065, Australia
关键词
stroke volume; cardiac output; echocardiography; transthoracic; magnetic resonance imaging; VENTRICULAR OUTFLOW TRACT; AORTIC-VALVE AREA; TRANSESOPHAGEAL ECHOCARDIOGRAPHY; EUROPEAN ASSOCIATION; AMERICAN SOCIETY; RECOMMENDATIONS; QUANTIFICATION; AGREEMENT; STENOSIS; UPDATE;
D O I
10.1053/j.jvca.2023.05.024
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Objectives: The authors aimed to compare the assessment of left ventricular (LV) stroke volume with transthoracic echocardiography (TTE) using 2-and 3-dimensional (2D and 3D) Doppler and volumetric techniques with gold standard cardiac magnetic resonance imaging (CMR).Design: An observational study.Setting: A medical research institute.Participants: A total of 187 volunteer participants free of known structural heart disease.Interventions: None.Measurements and Main Results: LV stroke volume was measured with TTE using the following 4 techniques: LV outflow tract (LVOT) pulsed wave Doppler with 2D LVOT area, LVOT pulsed wave Doppler with 3D LVOT area, 2D volumetric (Simpson's biplane), and 3D volumetric techniques. This was compared with gold standard CMR. Stroke volume measured with echocardiography underestimated stroke volume com-pared to CMR by all techniques (p < 0.001 for all values compared to CMR). The LVOT Doppler stroke volume with a 3D area most closely agreed with CMR, with a bias of 6.35%. This bias progressively increased with 3D volumetric (13.4%), LVOT Doppler with a 2D area (15.1%), and 2D volumetric (18.3%) stroke volume techniques, with wider limits of agreement.Conclusion: Of the 4 echocardiographic LV stroke volume measurement methods the authors assessed, stroke volume with LVOT Doppler using 3D measurement of LVOT area most closely approximates gold standard CMR.Crown Copyright & COPY; 2023 Published by Elsevier Inc. All rights reserved.
引用
收藏
页码:1639 / 1645
页数:7
相关论文
共 50 条
  • [21] Left Ventricular Ejection Fraction Correlation With Stroke Volume as Estimated by Doppler Echocardiography in Cardiogenic Shock: A Retrospective Observational Study
    Lashin, Hazem
    Olusanya, Olusegun
    Smith, Andrew
    Bhattacharyya, Sanjeev
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2022, 36 (09) : 3511 - 3516
  • [22] Stroke volume and cardiac output measurement in cardiac patients during a rehabilitation program: comparison between tonometry, impedancemetry and echocardiography
    Gonzalez-Represas, Alicia
    Mourot, Laurent
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2020, 36 (03) : 447 - 455
  • [23] Cardiac and paracardiac masses: Complementary role of echocardiography and magnetic resonance imaging
    Wann, LS
    Sampson, C
    Liu, Y
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 1998, 15 (02): : 139 - 146
  • [24] Update on Cardiac Imaging Techniques: Echocardiography, Cardiac Magnetic Resonance, and Multidetector Computed Tomography
    Velasco del Castilloa, Sonia
    Aguilar Torres, Rio
    Pare Bardera, Juan C.
    REVISTA ESPANOLA DE CARDIOLOGIA, 2009, 62 : 129 - 150
  • [25] Cardiac computed tomography and magnetic resonance imaging vs. transoesophageal echocardiography for diagnosing left atrial appendage thrombi
    Vira, Tasnim
    Pechlivanoglou, Petros
    Connelly, Kim
    Wijeysundera, Harindra C.
    Roifman, Idan
    EUROPACE, 2019, 21 (01): : E1 - E10
  • [26] Continuous Rapid Quantification of Stroke Volume Using Magnetohydrodynamic Voltages in 3T Magnetic Resonance Imaging
    Gregory, T. Stan
    Oshinski, John
    Schmidt, Ehud J.
    Kwong, Raymond Y.
    Stevenson, William G.
    Tse, Zion Tsz Ho
    CIRCULATION-CARDIOVASCULAR IMAGING, 2015, 8 (12)
  • [27] The evaluation of right ventricular systolic function in patients with repaired Tetralogy of Fallot by conventional echocardiographic methods and speckle tracking echocardiography: Compared with the gold standard cardiac mangenetic resonance
    Kavurt, Ahmet Vedat
    Pac, Feyza Aysenur
    Koca, Serhat
    Mihcioglu, Ajda Mutlu
    Yigit, Hasan
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2019, 36 (12): : 2251 - 2258
  • [28] Quantification of left ventricular mass using cardiac magnetic resonance imaging compared with echocardiography in domestic cats
    MacDonald, KA
    Kittleson, MD
    Reed, T
    Larson, R
    Kass, P
    Wisner, ER
    VETERINARY RADIOLOGY & ULTRASOUND, 2005, 46 (03) : 192 - 199
  • [29] Estimation of Stroke Volume and Aortic Valve Area in Patients With Aortic Stenosis: A Comparison of Doppler-Echocardiography and Cardiac Magnetic Resonance
    Capoulade, Romain
    Le Ven, Florent
    Garcia, Julio
    Tastet, Lionel
    Dahou, Abdellaziz
    Dumesnil, Jean G.
    Arsenault, Marie
    Bedard, Elisabeth
    Larose, Eric
    Pibarot, Philippe
    CIRCULATION, 2014, 130
  • [30] Measurement of left ventricular volume after anterior myocardial infarction: comparison of magnetic resonance imaging, echocardiography, and radionuclide ventriculography
    K.H. Darasz
    S.R. Underwood
    J. Bayliss
    S.M. Forbat
    J. Keegan
    P.A. Poole-Wilson
    G.C. Sutton
    The International Journal of Cardiovascular Imaging, 2002, 18 : 135 - 142