Measurement of Stroke Volume With Echocardiography Compared to Gold Standard Cardiac Magnetic Resonance Imaging: An Observational Study

被引:4
|
作者
Cowie, Brian [1 ,2 ,3 ,4 ]
Wright, Leah [2 ]
Costello, Ben [2 ]
Janssens, Kristel [2 ]
Howden, Erin [2 ]
Flannery, Darragh [2 ]
Foulkes, Steve [2 ]
Kluger, Roman [1 ,3 ]
La Gerche, Andre [2 ]
机构
[1] St Vincents Hosp, Dept Anaesthesia, Melbourne, Australia
[2] Baker Heart & Diabet Inst, Sports Cardiol, Melbourne, Australia
[3] Univ Melbourne, Dept Crit Care, Melbourne, Australia
[4] St Vincents Hosp, Dept Anaesthesia & Acute Pain Med, 45 Victoria Parade, Fitzroy 3065, Australia
关键词
stroke volume; cardiac output; echocardiography; transthoracic; magnetic resonance imaging; VENTRICULAR OUTFLOW TRACT; AORTIC-VALVE AREA; TRANSESOPHAGEAL ECHOCARDIOGRAPHY; EUROPEAN ASSOCIATION; AMERICAN SOCIETY; RECOMMENDATIONS; QUANTIFICATION; AGREEMENT; STENOSIS; UPDATE;
D O I
10.1053/j.jvca.2023.05.024
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Objectives: The authors aimed to compare the assessment of left ventricular (LV) stroke volume with transthoracic echocardiography (TTE) using 2-and 3-dimensional (2D and 3D) Doppler and volumetric techniques with gold standard cardiac magnetic resonance imaging (CMR).Design: An observational study.Setting: A medical research institute.Participants: A total of 187 volunteer participants free of known structural heart disease.Interventions: None.Measurements and Main Results: LV stroke volume was measured with TTE using the following 4 techniques: LV outflow tract (LVOT) pulsed wave Doppler with 2D LVOT area, LVOT pulsed wave Doppler with 3D LVOT area, 2D volumetric (Simpson's biplane), and 3D volumetric techniques. This was compared with gold standard CMR. Stroke volume measured with echocardiography underestimated stroke volume com-pared to CMR by all techniques (p < 0.001 for all values compared to CMR). The LVOT Doppler stroke volume with a 3D area most closely agreed with CMR, with a bias of 6.35%. This bias progressively increased with 3D volumetric (13.4%), LVOT Doppler with a 2D area (15.1%), and 2D volumetric (18.3%) stroke volume techniques, with wider limits of agreement.Conclusion: Of the 4 echocardiographic LV stroke volume measurement methods the authors assessed, stroke volume with LVOT Doppler using 3D measurement of LVOT area most closely approximates gold standard CMR.Crown Copyright & COPY; 2023 Published by Elsevier Inc. All rights reserved.
引用
收藏
页码:1639 / 1645
页数:7
相关论文
共 50 条
  • [1] Cardiac Magnetic Resonance Imaging and Transthoracic Echocardiography: Investigation of Concordance between the Two Methods for Measurement of the Cardiac Chamber
    Gurdogan, Muhammet
    Ustabasioglu, Fethi Emre
    Kula, Osman
    Korkmaz, Selcuk
    MEDICINA-LITHUANIA, 2019, 55 (06):
  • [2] Estimation of Stroke Volume and Aortic Valve Area in Patients with Aortic Stenosis: A Comparison of Echocardiography versus Cardiovascular Magnetic Resonance
    Guzzetti, Ezequiel
    Capoulade, Romain
    Tastet, Lionel
    Garcia, Julio
    Le Ven, Florent
    Arsenault, Marie
    Bedard, Elisabeth
    Larose, Eric
    Clavel, Marie-Annick
    Pibarot, Philippe
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2020, 33 (08) : 953 - +
  • [3] Accuracy of stroke volume measurement with phase-contrast cardiovascular magnetic resonance in patients with aortic stenosis
    Guzzetti, Ezequiel
    Racine, Hugo-Pierre
    Tastet, Lionel
    Shen, Mylene
    Larose, Eric
    Clavel, Marie-Annick
    Pibarot, Philippe
    Beaudoin, Jonathan
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2021, 23 (01)
  • [4] 3D-speckle-tracking echocardiography correlates with cardiovascular magnetic resonance imaging diagnosis of acute myocarditis - An observational study
    Goody, Philip Roger
    Zimmer, Sebastian
    Oeztuerk, Can
    Zimmer, Angela
    Kreuz, Jens
    Becher, Marc Ulrich
    Isaak, Alexander
    Luetkens, Julian
    Sugiura, Atsushi
    Jansen, Felix
    Nickenig, Georg
    Hammerstingl, Christoph
    Tiyerili, Vedat
    IJC HEART & VASCULATURE, 2022, 41
  • [5] Quantification of left ventricular mass by echocardiography compared to cardiac magnet resonance imaging in hemodialysis patients
    Grebe, Soeren Jendrik
    Malzahn, Uwe
    Donhauser, Julian
    Liu, Dan
    Wanner, Christoph
    Krane, Vera
    Hammer, Fabian
    CARDIOVASCULAR ULTRASOUND, 2020, 18 (01)
  • [6] Evaluation of left ventricular function and volume by two-dimensional echocardiography in a pediatric population: Correlation with cardiac magnetic resonance imaging
    Bhansali, Suneet
    Tokar, Ella
    Saharan, Sunil
    Khalil, Ramzi
    Bhatla, Puneet
    ANNALS OF PEDIATRIC CARDIOLOGY, 2024, 17 (01) : 28 - 35
  • [7] Imaging of the mitral valve: role of echocardiography, cardiac magnetic resonance, and cardiac computed tomography
    Namazi, Farnaz
    Vo, N. Mai
    Delgado, Victoria
    CURRENT OPINION IN CARDIOLOGY, 2020, 35 (05) : 435 - 444
  • [8] Non-invasive stroke volume measurement by cardiac magnetic resonance imaging and inert gas rebreathing in pulmonary hypertension
    McLure, Lindsey E. R.
    Brown, Aileen
    Lee, Waiting N.
    Church, Alistair C.
    Peacock, Andrew J.
    Johnson, Martin K.
    CLINICAL PHYSIOLOGY AND FUNCTIONAL IMAGING, 2011, 31 (03) : 221 - 226
  • [9] Prospective comparison of echocardiography versus cardiac magnetic resonance imaging in patients with Ebstein's anomaly
    Jost, Christine H. Attenhofer
    Edmister, Whitney D.
    Julsrud, Paul R.
    Dearani, Joseph A.
    Tepe, M. Savas
    Warnes, Carole A.
    Scott, Christopher G.
    Anavekar, Nandan S.
    Ammash, Naser M.
    Connolly, Heidi M.
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2012, 28 (05) : 1147 - 1159
  • [10] Cardiac magnetic resonance imaging with standard imaging planes for mitral valve scallop pathology: interrater agreement and comparison with echocardiography
    Sogaard, Stinne Byrholdt
    Gustavsen, Pia
    Dalsgaard, Morten
    Vejlstrup, Niels G.
    Madsen, Per Lav
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2021, 37 (02) : 605 - 611