Asymmetric Pt(II)-Porphyrin Incorporated in a PVC Ion-Selective Membrane for the Potentiometric Detection of Citrate

被引:2
作者
Vlascici, Dana [1 ]
Lascu, Anca [2 ]
Fratilescu, Ion [2 ]
Anghel, Diana [2 ]
Epuran, Camelia [2 ]
Birdeanu, Mihaela [3 ]
Chiriac, Vlad [1 ]
Fagadar-Cosma, Eugenia [2 ]
机构
[1] West Univ Timisoara, Fac Chem Biol Geog, 4 Vasile Parvan Ave, Timisoara 300223, Romania
[2] Inst Chem Coriolan Dragulescu, Mihai Viteazu Ave 24, Timisoara 300223, Romania
[3] Natl Inst Res & Dev Electrochem & Condensed Matter, Plautius Andronescu St 1, Timisoara 300224, Romania
关键词
Pt-metalloporphyrin; A(3)B porphyrin; potentiometric sensor; PVC membrane; citrate ion detection; SOFT DRINKS; PI-PI; ELECTRODES; NANOPARTICLES; PORPHYRINS; PLATINUM(II); BEVERAGES; GRAPHITE; GRAPHENE; SENSOR;
D O I
10.3390/chemosensors11020108
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new sensing material, Pt(II)-5-(4-carboxyphenyl)-10,15,20-tris(4-phenoxyphenyl)-porphyrin (Pt(II)-COOH-TPOPP), was synthesized and characterized. Polymeric membranes containing the porphyrin and three different plasticizers were used as an electroactive material for a new anion-selective sensor. The best composition of the membrane was the one plasticized with dioctylsebacate (DOS), the obtained sensor being citrate-selective in a linear range of 5 x 10(-7)-1 x 10(-1) M citrate. The slope was Nernstian (19.73 mV/decade) with good selectivity towards a number of interfering anions and a lifetime of five weeks.
引用
收藏
页数:17
相关论文
共 50 条
[21]   Cationic surfactant ion-selective PVC membrane electrode containing macrocyclic diimine crown ether [J].
Saleh, MB .
ANALYTICAL LETTERS, 1999, 32 (11) :2201-2215
[22]   Interpretation of the potential response of PVC membrane ion-selective electrodes based on the mixed potential theory [J].
Osakai, Toshiyuki ;
Sato, Yoshitsugu ;
Imoto, Maya ;
Sakaki, Toru .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2012, 668 :107-112
[23]   Preparation and Application of PVC Membrane Ion-Selective Electrode in Measuring pH of the Upper Digestive Tract [J].
姜学文 ;
霍纪文 .
中国医科大学学报, 1991, (S2) :49-54
[24]   Using PVC ion-selective electrodes for the potentiometric flow injection analysis of distigmine in its pharmaceutical formulation and biological fluids [J].
Issa, Yousry M. ;
Khorshid, Amal F. .
JOURNAL OF ADVANCED RESEARCH, 2011, 2 (01) :25-34
[25]   Thin Layer Membrane Systems as Rapid Development Tool for Potentiometric Solid Contact Ion-selective Electrodes [J].
Forrest, Tara ;
Zdrachek, Elena ;
Bakker, Eric .
ELECTROANALYSIS, 2020, 32 (04) :799-804
[26]   Potentiometric Characterization of Telomerase Activity Using a Copper(ii)-pyrophosphate Complex with a Copper ion-selective Electrode [J].
Liu, Wen ;
Huang, Jiahua ;
Zhu, Yiming ;
Zhang, Huan ;
Ning, Ning ;
Song, Caiting .
ANALYTICAL LETTERS, 2019, 52 (02) :353-362
[27]   Lead (II) Ion-Selective Membrane Electrodes Based on Four Nitrogen-Containing Heterocyclic Thioethers [J].
Yan, Zhenning ;
Dan, Junying ;
Li, Liqin ;
Wang, Shuangqiang ;
Zhao, Bangtun .
SENSOR LETTERS, 2012, 10 (1-2) :43-51
[28]   New cesium ion-selective PVC membrane electrode based on a novel calix[6]arene derivative [J].
Aslan, N. ;
Canel, E. ;
Yilmaz, M. ;
Kilic, E. .
BULGARIAN CHEMICAL COMMUNICATIONS, 2011, 43 (04) :526-531
[29]   NEW SILVER ION-SELECTIVE PVC MEMBRANE AND COATED-GRAPHITE ELECTRODES BASED ON A NOVEL CALIX[4]ARENE DERIVATIVE [J].
Erol, Sibel ;
Ozel, Ayca Demirel ;
Yilmaz, Mustafa ;
Kilic, Esma .
REVIEWS IN ANALYTICAL CHEMISTRY, 2009, 28 (01) :27-49
[30]   Selectivity, Sensitivity and Detection Range in Ion-Selective Membrane-Based Electrochemical Potentiometric Sensors Analyzed With Poisson-Boltzmann Equilibrium Model [J].
Mele, Leandro Julian ;
Palestri, Pierpaolo ;
Alam, Muhammad A. ;
Selmi, Luca .
IEEE SENSORS JOURNAL, 2022, 22 (15) :15010-15021