Asymmetric Pt(II)-Porphyrin Incorporated in a PVC Ion-Selective Membrane for the Potentiometric Detection of Citrate

被引:2
作者
Vlascici, Dana [1 ]
Lascu, Anca [2 ]
Fratilescu, Ion [2 ]
Anghel, Diana [2 ]
Epuran, Camelia [2 ]
Birdeanu, Mihaela [3 ]
Chiriac, Vlad [1 ]
Fagadar-Cosma, Eugenia [2 ]
机构
[1] West Univ Timisoara, Fac Chem Biol Geog, 4 Vasile Parvan Ave, Timisoara 300223, Romania
[2] Inst Chem Coriolan Dragulescu, Mihai Viteazu Ave 24, Timisoara 300223, Romania
[3] Natl Inst Res & Dev Electrochem & Condensed Matter, Plautius Andronescu St 1, Timisoara 300224, Romania
关键词
Pt-metalloporphyrin; A(3)B porphyrin; potentiometric sensor; PVC membrane; citrate ion detection; SOFT DRINKS; PI-PI; ELECTRODES; NANOPARTICLES; PORPHYRINS; PLATINUM(II); BEVERAGES; GRAPHITE; GRAPHENE; SENSOR;
D O I
10.3390/chemosensors11020108
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new sensing material, Pt(II)-5-(4-carboxyphenyl)-10,15,20-tris(4-phenoxyphenyl)-porphyrin (Pt(II)-COOH-TPOPP), was synthesized and characterized. Polymeric membranes containing the porphyrin and three different plasticizers were used as an electroactive material for a new anion-selective sensor. The best composition of the membrane was the one plasticized with dioctylsebacate (DOS), the obtained sensor being citrate-selective in a linear range of 5 x 10(-7)-1 x 10(-1) M citrate. The slope was Nernstian (19.73 mV/decade) with good selectivity towards a number of interfering anions and a lifetime of five weeks.
引用
收藏
页数:17
相关论文
共 50 条
  • [1] THIOCYANATE ION-SELECTIVE PVC MEMBRANE ELECTRODE
    Revenco, Mihail
    Martin, Mariana
    Abu Dayyih, Waell
    CHEMISTRY JOURNAL OF MOLDOVA, 2010, 5 (01): : 73 - 77
  • [2] Potentiometric PVC membrane ion–selective electrode for the determination of Sr(II) ions
    Özbek O.
    Sensors International, 2022, 3
  • [3] Improvement of Lower Detection Limit of Ion-Selective Electrodes Based on PVC Membrane
    Huang Meirong
    Ding Yongbo
    Li Xingui
    PROGRESS IN CHEMISTRY, 2012, 24 (08) : 1560 - 1571
  • [4] A New PVC-Membrane Based Ion-Selective Electrode for Perchlorate
    Yari, Abdollah
    Shamsipur, Mojtaba
    De Filippo, Greta
    Lippolis, Vito
    ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2009, 1 (02): : 60 - 70
  • [5] Ion-selective potentiometric determination of Pb(II) ions using PVC-based carboxymethyl cellulose Sn(IV) phosphate composite membrane electrode
    Inamuddin
    Naushad, Mu.
    Rangreez, Tauseef Ahmad
    ALOthman, Z. A.
    DESALINATION AND WATER TREATMENT, 2015, 56 (03) : 806 - 813
  • [6] Development of a new copper(II) ion-selective PVC membrane electrode based on tris(2-benzimidazolylmethyl)amine
    Tomar, Praveen Kumar
    Chandra, Sulekh
    Singh, Inderjeet
    Kumar, Avdhesh
    Malik, Amrita
    Singh, Arendra
    JOURNAL OF THE INDIAN CHEMICAL SOCIETY, 2011, 88 (11) : 1739 - 1744
  • [7] PVC membrane cesium ion-selective sensor based on cephalexin antibiotic
    Saleh, MB
    Hassan, SSM
    Gaber, AAA
    Kream, NAA
    ANALYTICAL LETTERS, 2003, 36 (11) : 2367 - 2377
  • [8] Pulsed Galvanostatic Control of a Polymeric Membrane Ion-Selective Electrode for Potentiometric Immunoassays
    Ding, Jiawang
    Wang, Xuewei
    Qin, Wei
    ACS APPLIED MATERIALS & INTERFACES, 2013, 5 (19) : 9488 - 9493
  • [9] A lead (II) selective PVC membrane potentiometric sensor based on a tetraazamacrocyclic ligand
    Mathew, Sobhana
    Rajith, Leena
    Lonappan, Laina Angamaly
    Jos, Theresa
    Kumar, Krishnapillai Girish
    JOURNAL OF INCLUSION PHENOMENA AND MACROCYCLIC CHEMISTRY, 2014, 78 (1-4) : 171 - 177
  • [10] Towards potentiometric detection in nonaqueous media: Evaluation of the impacts of organic solvents on polymeric membrane ion-selective electrodes
    Lin, Zhaoyang
    Liang, Rongning
    Qin, Wei
    TALANTA, 2022, 241