Sound pressure level real-time monitoring of outdoor directional noise

被引:5
作者
Chen, Yong [1 ,2 ]
Wu, Ming [1 ,2 ]
Lu, Ling [3 ]
Fang, Xing [1 ]
Yang, Jun [1 ,2 ]
机构
[1] Chinese Acad Sci, Inst Acoust, Key Lab Noise & Audio Acoust Res, Beijing 100190, Peoples R China
[2] Univ Chinese Acad Sci, Sch Elect Elect & Commun Engn, Beijing 100049, Peoples R China
[3] State Grid Hunan Elect Power Corp Res Inst, State Grid Lab Elect Equipment Noise & Vibrat Res, Changsha 410000, Peoples R China
关键词
Outdoor noise monitoring; Beamforming; Online sound pressure level calibration; MEMS microphone; CHD-MUSIC sound source localization; Array microphone; MICROPHONE ARRAY; SOURCE LOCALIZATION; CALIBRATION;
D O I
10.1016/j.apacoust.2022.109141
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
A single microphone can't select an efficient target signal from a mixed sound source when measuring the sound pressure level (SPL) of a target noise source in an outdoor environment. Therefore, a microphone array is used to enhance the target signal through beamforming to restrain the interference of non-target signals effectively. Owing to their advantages of small size and low price, micro-electro-mechanical system (MEMS) microphone arrays are widely used. However, MEMS microphone mismatch commonly occurs due to production tolerances as well as aging effects. To calibrate the SPL measurement difference caused by the whole mismatch microphone array when outdoor noise monitoring is performed, a realtime calibration method was introduced in this study by compensating for the SPL difference between the reference microphone and MEMS microphone array. The circular harmonics domain-multiple signal classification sound source localization algorithm was utilized to select the effective target signal component in the time-frequency domain, and the standard transfer functions of the reference microphone were utilized to correct the SPL measurement bias of the array. To verify the feasibility of the method, the consistency of the compensating SPL difference between multi-noise and single-target noise environments was experimentally investigated. The calibration method exhibited good accuracy and robustness based on the results and can also be applied to spherical microphone array noise monitoring device.(c) 2022 Elsevier Ltd. All rights reserved.
引用
收藏
页数:12
相关论文
共 27 条
[1]  
[Anonymous], 1997, 3 AIAA CEAS AER C
[2]   Acoustic localization and tracking of a multi-rotor unmanned aerial vehicle using an array with few microphones [J].
Blanchard, T. ;
Thomas, J. -H. ;
Raoof, K. .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2020, 148 (03) :1456-1467
[3]   Self-calibrating microphone arrays for speech signal acquisition: A systematic approach [J].
Buck, M ;
Haulick, T ;
Pfleiderer, HM .
SIGNAL PROCESSING, 2006, 86 (06) :1230-1238
[4]   Noise spectrum estimation in adverse environments: Improved minima controlled recursive averaging [J].
Cohen, I .
IEEE TRANSACTIONS ON SPEECH AND AUDIO PROCESSING, 2003, 11 (05) :466-475
[5]  
Colton D. L., 1998, INVERSE ACOUSTIC ELE
[6]   On the asymptotic performance analysis of subspace DOA estimation in the presence of modeling errors:: Case of MUSIC [J].
Ferréol, A ;
Larzabal, P ;
Viberg, M .
IEEE TRANSACTIONS ON SIGNAL PROCESSING, 2006, 54 (03) :907-920
[7]  
Gade S, 2015, SOUND VIB, P9
[8]  
Gradshteyn I. S., 2014, TABLE INTEGRALS SERI
[9]   Sound source localization using multiple circular microphone arrays based on harmonic analysis [J].
Han, Xinyu ;
Wu, Ming ;
Han, Zerui ;
Yang, Jun .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2021, 149 (05) :3517-3523
[10]   Semi-Supervised Multiple Source Localization Using Relative Harmonic Coefficients Under Noisy and Reverberant Environments [J].
Hu, Yonggang ;
Samarasinghe, Prasanga N. ;
Gannot, Sharon ;
Abhayapala, Thushara D. .
IEEE-ACM TRANSACTIONS ON AUDIO SPEECH AND LANGUAGE PROCESSING, 2020, 28 (28) :3108-3123