Evaluating the efficiency and safety of large-volume leukapheresis using the Spectra Optia continuous mononuclear cell collection protocol for peripheral blood stem cell collection from healthy donors: A retrospective study

被引:2
|
作者
Sumii, Yuichi [1 ,2 ]
Fujii, Keiko [3 ,4 ]
Kondo, Takumi [4 ]
Urata, Tomohiro [1 ,2 ]
Kimura, Maiko [1 ,2 ]
Fujiwara, Hideaki [4 ]
Asada, Noboru [4 ]
Ennishi, Daisuke [2 ,5 ]
Nishimori, Hisakazu [4 ]
Matsuoka, Ken-ichi [2 ]
Otsuka, Fumio [3 ,6 ]
Maeda, Yoshinobu [2 ]
Fujii, Nobuharu [1 ,4 ]
机构
[1] Okayama Univ Hosp, Div Blood Transfus, Okayama, Japan
[2] Okayama Univ, Grad Sch Med Dent & Pharmaceut Sci, Dept Hematol Oncol & Resp Med, Okayama, Japan
[3] Okayama Univ Hosp, Div Clin Lab, 2-5-1 Shikata Cho, Kita Ku, Okayama, Okayama 7008558, Japan
[4] Okayama Univ Hosp, Dept Hematol & Oncol, Okayama, Japan
[5] Okayama Univ Hosp, Ctr Comprehens Genom Med, Okayama, Japan
[6] Okayama Univ, Grad Sch Med Dent & Pharmaceut Sci, Dept Gen Med, Okayama, Japan
关键词
blood center operations; therapeutic apheresis; transplantation-stem cell; COLONY-STIMULATING FACTOR; PROGENITOR CELLS; CROSSOVER TRIAL; FORMING-UNITS; BONE-MARROW; MOBILIZATION; APHERESIS; COUNTS; YIELDS; EXPERIENCES;
D O I
10.1111/trf.17563
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Large-volume leukapheresis (LVL) refers to processing of more than three volumes of blood in a single session for peripheral blood stem cell collection. Recently, continuous mononuclear cell collection (cMNC) protocol has been developed using the Spectra Optia system, which is a widely used apheresis device. LVL using the novel protocol has been investigated in patients. However, the efficiency and safety of LVL in healthy donors using this protocol has not been characterized. Therefore, this study aimed to evaluate the efficiency and tolerability of CD34(+) collection of LVL with the cMNC protocol in healthy donors.Study Design and Methods: We retrospectively collected data on LVL (>3 total blood volume) and normal-volume leukapheresis (NVL) performed in healthy donors between October 2019 and December 2021. All procedures were performed using the cMNC protocol.Results: Although pre-apheresis CD34(+) cell count was lesser in LVL (23.5 vs. 58.0/mu L, p < .001), CD34(+) collection efficiency was comparable between LVL and NVL (61.2% vs. 61.4%, p = .966). Platelet loss was significantly higher in LVL compared to NVL (38.0% vs. 29.4%, p < .001), with no correlation between attrition of platelet and processing blood volume. Moreover, the incidence of citrate toxicity during procedures was comparable between the two groups (31.6% vs. 21.4%, p = .322). All LVL procedures could be completed without any adverse events.Conclusion: Allogeneic LVL procedure using Spectra Optia cMNC protocol was well tolerated by the donors and resulted in efficient collection of CD34(+) cells, which was comparable to that of NVL.
引用
收藏
页码:2120 / 2130
页数:11
相关论文
共 13 条
  • [1] Comparison between intermittent and continuous spectra optia leukapheresis systems for autologous peripheral blood stem cell collection
    Lisenko, Katharina
    Pavel, Petra
    Bruckner, Thomas
    Puthenparambil, Joe
    Hundemer, Michael
    Schmitt, Anita
    Witzens-Harig, Mathias
    Ho, Anthony D.
    Wuchter, Patrick
    JOURNAL OF CLINICAL APHERESIS, 2017, 32 (01) : 27 - 34
  • [2] Peripheral blood stem cells collection on spectra optia apheresis system using the continuous mononuclear cell collection protocol: A single center report of 39 procedures
    Sanderson, F.
    Poullin, P.
    Smith, R.
    Nicolino-Brunet, C.
    Philip, P.
    Chaib, A.
    Costello, R.
    JOURNAL OF CLINICAL APHERESIS, 2017, 32 (03) : 182 - 190
  • [3] Low hematocrit reduces the efficiency of CD34(+) cell collection when using the Spectra Optia continuous mononuclear cell collection procedure
    Kondo, Takumi
    Fujii, Nobuharu
    Fujii, Keiko
    Sumii, Yuichi
    Urata, Tomohiro
    Kimura, Maiko
    Matsuda, Masayuki
    Ikegawa, Shuntaro
    Washio, Kana
    Fujiwara, Hideaki
    Asada, Noboru
    Ennishi, Daisuke
    Nishimori, Hisakazu
    Matsuoka, Ken-ichi
    Otsuka, Fumio
    Maeda, Yoshinobu
    TRANSFUSION, 2022, 62 (05) : 1065 - 1072
  • [4] Comparison of three mobilization protocols for peripheral blood stem cell apheresis with Spectra Optia continuous mononuclear cell protocol in healthy dogs
    Kim, Sangho
    Hosoya, Kenji
    Kobayashi, Ayumi
    Okumura, Masahiro
    VETERINARY AND COMPARATIVE ONCOLOGY, 2019, 17 (01) : 61 - 68
  • [5] Large-volume leukapheresis using femoral venous access for harvesting peripheral blood stem cells with the fenwal CS 3000 plus from normal healthy donors: Predictors of CD34+ cell yield and collection efficiency
    Sohn, SK
    Kim, JG
    Chae, YS
    Kim, DH
    Lee, NY
    Suh, JS
    Lee, KB
    JOURNAL OF CLINICAL APHERESIS, 2003, 18 (01) : 10 - 15
  • [6] Evaluation of the Spectra Optia Apheresis System for Mononuclear Cell (MNC) Collection in G-CSF Mobilized and Nonmobilized Healthy Donors: Results of a Multicenter Study
    Karafin, Matthew S.
    Graminske, Sharon
    Erickson, Paulette
    Walters, Mark C.
    Scott, Edward P.
    Carter, Scott
    Padmanabhan, Anand
    JOURNAL OF CLINICAL APHERESIS, 2014, 29 (05) : 273 - 280
  • [7] Successful autologous peripheral blood stem cell collection using large volume leukapheresis in patients with very low or undetectable peripheral blood CD34+progenitor cells
    Destrampe, Eric
    Schlueter, Annette J.
    TRANSFUSION AND APHERESIS SCIENCE, 2021, 60 (04)
  • [8] Large volume leukapheresis in small children: safety profile and variables affecting peripheral blood progenitor cell collection
    J Sevilla
    M González-Vicent
    L Madero
    F García-Sánchez
    M Angel Diaz
    Bone Marrow Transplantation, 2003, 31 : 263 - 267
  • [9] Progenitor cell mobilization -: Large volume leukapheresis in small children:: safety profile and variables affecting peripheral blood progenitor cell collection
    Sevilla, J
    González-Vicent, M
    Madero, L
    García-Sánchez, F
    Díaz, MA
    BONE MARROW TRANSPLANTATION, 2003, 31 (04) : 263 - 267
  • [10] Anticoagulation in large-volume leukapheresis: comparison between citrate- versus heparin-based anticoagulation on safety and CD34+ cell collection efficiency
    Dettke, Markus
    Buchta, Christoph
    Wiesinger, Helfried
    Maas, Jens-Holger
    Strate, Alexander
    Chen, Ying
    CYTOTHERAPY, 2012, 14 (03) : 350 - 358