Evaluation of image quality of diffusion weighted readout segmentation of long variable echo-trains MR pulse sequence for lumbosacral nerve imaging at 3T br

被引:2
作者
Abdulaal, Osamah M. [1 ,2 ]
MacMahon, Peter J. [3 ,4 ]
Rainford, Louise [2 ]
Cradock, Andrea [2 ]
O'Driscoll, Dearbhail [3 ]
Galligan, Marie [2 ]
Alshoabi, Sultan A. [1 ]
Alsharif, Walaa [1 ]
McGee, Allison [2 ]
机构
[1] Taibah Univ, Coll Appl Med Sci, Diagnost Radiol Technol, Madina, Saudi Arabia
[2] Univ Coll Dublin, Sch Med, Diagnost Imaging, Dublin, Ireland
[3] Mater Misericordiae Univ Hosp, Dept Radiol, Dublin, Ireland
[4] Univ Coll Dublin, Sch Med, Dublin, Ireland
关键词
Magnetic resonance imaging; spine; diffusion weighted imaging; MAGNETIC-RESONANCE NEUROGRAPHY; CLINICAL-APPLICATION; FAT-SUPPRESSION; PERFORMANCE; ARTIFACTS; DIAGNOSIS; IMPROVES; RESOLVE; PHANTOM; KNEE;
D O I
10.21037/qims-22-191
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: Limited magnetic resonance (MR) pulse sequences facilitate lumbosacral nerve imaging with acceptable image quality. This study aimed to evaluate the impact of parameter modification for Diffusion Weighted Image (DWI) using Readout Segmentation of Long Variable Echo-trains (RESOLVE) sequence with opportunities for improving the visibility of lumbosacral nerves and image quality.Methods: Following ethical approval and acquisition of informed consent, imaging of an MR phantom and twenty healthy volunteers (n=20) was prospectively performed with 3T MRI scanner. Acquired sequences included standard two-dimensional (2D) turbo spin echo sequences and readout-segmented echo-planar imaging (EPI) DWI-RESOLVE using three different b-values b-50, b-500 and b-800 s/mm2. Signal-to-noise ratio (SNR), apparent diffusion coefficient (ADC) and nerve size were measured. Two musculoskeletal radiologists evaluated anatomical structure visualisation and image quality. Quantitative and qualitative findings for healthy volunteers were investigated for differences using Wilcoxon signed-rank and Friedman tests, respectively. Inter and intra-observer agreement was determined with Kappa statistics.Results: Phantom images revealed higher SNR for images with low b-values with 206.1 (+/- 10.9), 125.1 (+/- 45.2) and 59.2 (+/- 17.8) for DWI-RESOLVE images acquired at b50, b500 and b800, respectively. Comparable results were found for SNR, ADC and nerve size across normal right and left sided for healthy volunteer images. The SNR findings for b-50 images were higher than b-500 and b-800 images for healthy volunteer images. The qualitative findings ranked images acquired using b-50 and b-500 images significantly higher than corresponding b-800 images (P<0.05). Inter and intra-observer agreements for evaluation across all b-values ranged from 0.59 to 0.81 and 0.83 to 0.92, respectively.Conclusions: The modified DWI-RESOLVE images facilitated visualization of the normal lumbosacral nerves with acceptable image quality, which support the clinical applicability of this sequence
引用
收藏
页码:196 / 209
页数:14
相关论文
共 44 条
[1]   Identifying lumbosacral plexus nerve root abnormalities in patients with sciatica using 3T readout-segmented echo-planar diffusion weighted MR neurography [J].
Abdulaal, Osamah M. ;
McGee, Allison ;
Rainford, Louise ;
O'Driscoll, Dearbhail ;
Galligan, Marie ;
Reid, Valerie ;
MacMahon, Peter J. .
INSIGHTS INTO IMAGING, 2021, 12 (01)
[2]   Diffusion-weighted imaging of the liver: an update [J].
Bharwani, N. ;
Koh, D. M. .
CANCER IMAGING, 2013, 13 (02) :171-185
[3]   Readout-segmented Echo-pIanar Imaging Improves the Diagnostic Performance of Diffusion-weighted MR Breast Examinations at 3.0 T [J].
Bogner, Wolfgang ;
Pinker-Domenig, Katja ;
Bickel, Hubert ;
Chmelik, Marek ;
Weber, Michael ;
Helbich, Thomas H. ;
Trattnig, Siegfried ;
Gruber, Stephan .
RADIOLOGY, 2012, 263 (01) :64-76
[4]   High resolution neurography of the lumbosacral plexuson 3T magneteic resonance imaging [J].
Cejas, C. ;
Escobar, I. ;
Serra, M. ;
Barroso, F. .
RADIOLOGIA, 2015, 57 (01) :22-34
[5]   The utility of high b-value DWI in evaluation of ischemic stroke at 3 T [J].
Cihangiroglu, Mutlu ;
Citci, Beyza ;
Kilickesmez, Ozgur ;
Firat, Zeynep ;
Karlikaya, Geysu ;
Ulug, Aziz M. ;
Bingol, Canan A. ;
Kovanlikaya, Ilhami .
EUROPEAN JOURNAL OF RADIOLOGY, 2011, 78 (01) :75-81
[6]  
Demir ÖI, 2007, DIAGN INTERV RADIOL, V13, P81
[7]   Measurement of signal-to-noise ratios in MR images: Influence of multichannel coils, parallel imaging, and reconstruction filters [J].
Dietrich, Olaf ;
Raya, Jose G. ;
Reeder, Scott B. ;
Reiser, Maximilian F. ;
Schoenberg, Stefan O. .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2007, 26 (02) :375-385
[8]   Diffusion-weighted magnetic resonance imaging of symptomatic nerve root of patients with lumbar disk herniation [J].
Eguchi, Yawara ;
Ohtori, Seiji ;
Yamashita, Masaomi ;
Yamauchi, Kazuyo ;
Suzuki, Munetaka ;
Orita, Sumihisa ;
Kamoda, Hiroto ;
Arai, Gen ;
Ishikawa, Tetsuhiro ;
Miyagi, Masayuki ;
Ochiai, Nobuyasu ;
Kishida, Shunji ;
Inoue, Gen ;
Masuda, Yoshitada ;
Ochi, Shigehiro ;
Kikawa, Takashi ;
Toyone, Tomoaki ;
Takaso, Masashi ;
Aoki, Yasuchika ;
Takahashi, Kazuhisa .
NEURORADIOLOGY, 2011, 53 (09) :633-641
[9]   Clinical applications of diffusion magnetic resonance imaging of the lumbar foraminal nerve root entrapment [J].
Eguchi, Yawara ;
Ohtori, Seiji ;
Yamashita, Masaomi ;
Yamauchi, Kazuyo ;
Suzuki, Munetaka ;
Orita, Sumihisa ;
Kamoda, Hiroto ;
Arai, Gen ;
Ishikawa, Tetsuhiro ;
Miyagi, Masayuki ;
Ochiai, Nobuyasu ;
Kishida, Shunji ;
Masuda, Yoshitada ;
Ochi, Shigehiro ;
Kikawa, Takashi ;
Takaso, Masashi ;
Aoki, Yasuchika ;
Toyone, Tomoaki ;
Suzuki, Takane ;
Takahashi, Kazuhisa .
EUROPEAN SPINE JOURNAL, 2010, 19 (11) :1874-1882
[10]   Simultaneous multi-slice readout-segmented echo planar imaging for accelerated diffusion-weighted imaging of the breast [J].
Filli, Lukas ;
Ghafoor, Soleen ;
Kenkel, David ;
Liu, Wei ;
Weiland, Elisabeth ;
Andreisek, Gustav ;
Frauenfelder, Thomas ;
Runge, Val M. ;
Boss, Andreas .
EUROPEAN JOURNAL OF RADIOLOGY, 2016, 85 (01) :274-278