Microgrid Hybrid Solar/Wind/Diesel and Battery Energy Storage Power Generation System: Application to Koh Samui, Southern Thailand

被引:11
作者
Khamharnphol, Rawit [1 ]
Kamdar, Ismail [2 ]
Waewsak, Jompob [2 ]
Chaichan, Weerasak [3 ]
Khunpetch, Sakrapee [1 ]
Chiwamongkhonkarn, Somphol [2 ]
Kongruang, Chuleerat [4 ]
Gagnon, Yves [5 ]
机构
[1] Nakhon Si Thammarat Rajabhat Univ, Fac Ind Technol, Nakhon Si Thammarat, Thailand
[2] Thaksin Univ, Fac Sci, Res Ctr Energy & Environm, Div Phys, Phatthalung Campus, Phatthalung, Thailand
[3] Thaksin Univ, Fac Engn, Phatthalung Campus, Phatthalung, Thailand
[4] Walailak Univ, Sch Accountancy & Finance, Nakhon Si Thammarat, Thailand
[5] Univ Moncton, Edmundston, NB, Canada
来源
INTERNATIONAL JOURNAL OF RENEWABLE ENERGY DEVELOPMENT-IJRED | 2023年 / 12卷 / 02期
关键词
Solar PV; Wind Turbine Generator; Optimization; Levelized Cost of Energy; Renewable Fraction; Battery Energy Storage System; TECHNOECONOMIC ANALYSIS; FEASIBILITY ANALYSIS; DESIGN; ELECTRIFICATION; OPTIMIZATION; COMMUNITIES; OPERATION; AREAS;
D O I
10.14710/ijred.2023.47761
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This paper presents the optimization of a 10 MW solar/wind/diesel power generation system with a battery energy storage system (BESS) for one feeder of the distribution system in Koh Samui, an island in southern Thailand. The main objectives are to maximize the deployment of renewable energy-based power generation and to minimize the levelized cost of energy (LCOE). A hybrid renewable energy-based power generation system, consisting of solar PV, wind turbine generators, diesel generator (DiG), bi-directional grid-tied charging inverter (CONV) and BESS, was simulated using HOMER Pro (R). This study accessed the database of the National Aeronautics and Space Administration (NASA) for the Surface meteorology and Solar Energy (SSE) for the global solar radiation and temperature, along with the Modern-Era Retrospective analysis for Research and Applications (MERRA-2) wind database. The simulations show that Scenario 1 (PV/Wind/DiG/BESS/CONV) and Scenario 3 (PV/DiG/BESS/CONV) are the optimal configurations regarding the economic indicators (i.e. minimum net present costs (NPC) of 438 M$ and LCOE of 0.20$/kWh) and the environmental indicators (i.e. lowest greenhouse gases (GHG) emission avoidances of 6,339 tonnes/year and highest renewable fraction (RF) of 89.4%). Furthermore, the sensitivity analysis illustrates that Scenario 3 offers the optimal system type with the largest annual energy production (AEP). Besides contributing to the body of knowledge of optimization methodologies for microgrid hybrid power systems, the outcome of this work will assist the regional energy practitioners and policy makers regarding optimal configurations of microgrid hybrid systems in the development of a Green Island concept for Koh Samui.
引用
收藏
页码:216 / 226
页数:11
相关论文
共 50 条
  • [41] Optimization and sustainability analysis of PV/wind/diesel hybrid energy system for decentralized energy generation
    Nsafon, Benyoh Emmanuel Kigha
    Owolabi, Abdulhameed Babatunde
    Butu, Hemen Mark
    Roh, Jong Wook
    Suh, Dongjun
    Huh, Jeung-Soo
    ENERGY STRATEGY REVIEWS, 2020, 32
  • [42] Electric System Cascade Extended Analysis for optimal sizing of an autonomous hybrid CSP/PV/wind system with Battery Energy Storage System and thermal energy storage
    Chennaif, Mohammed
    Zahboune, Hassan
    Elhafyani, Mohammed
    Zouggar, Smail
    ENERGY, 2021, 227
  • [43] Optimization-based power management for battery/supercapacitor hybrid energy storage system with load estimation capability in a DC microgrid
    Farrokhi, Ehsan
    Ghoreishy, Hoda
    Ahangar, Roya Ahmadi
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2024, 155
  • [45] Hybrid Renewable Power Generation for Modeling and Controlling the Battery Storage Photovoltaic System
    Mustafa, Mohd
    Anandhakumar, G.
    Jacob, Anju Anna
    Singh, Ngangbam Phalguni
    Asha, S.
    Jayadhas, S. Arockia
    INTERNATIONAL JOURNAL OF PHOTOENERGY, 2022, 2022
  • [46] Dynamic optimization of solar-wind hybrid system connected to electrical battery or hydrogen as an energy storage system
    Shams, Sina Akhavan
    Ahmadi, Rouhollah
    INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2021, 45 (07) : 10630 - 10654
  • [47] Subregional optimization of wind-solar microgrid composite energy storage system
    Tian D.
    Chen Z.
    Nongye Gongcheng Xuebao/Transactions of the Chinese Society of Agricultural Engineering, 2019, 35 (21): : 196 - 201
  • [48] Multiobjective Optimization of a Hybrid PV/Wind/Battery/Diesel Generator System Integrated in Microgrid: A Case Study in Djelfa, Algeria
    Belboul, Zakaria
    Toual, Belgacem
    Kouzou, Abdellah
    Mokrani, Lakhdar
    Bensalem, Abderrahman
    Kennel, Ralph
    Abdelrahem, Mohamed
    ENERGIES, 2022, 15 (10)
  • [49] Dynamic power allocation of battery-supercapacitor hybrid energy storage for standalone PV microgrid applications
    Jing, Wenlong
    Lai, Chean Hung
    Wong, Wallace S. H.
    Wong, M. L. Dennis
    SUSTAINABLE ENERGY TECHNOLOGIES AND ASSESSMENTS, 2017, 22 : 55 - 64
  • [50] Size optimization of a PV/wind hybrid energy conversion system with battery storage using simulated annealing
    Ekren, Orhan
    Ekren, Banu Y.
    APPLIED ENERGY, 2010, 87 (02) : 592 - 598