The Precision of Different Types of Plates Fabricated With a Computer-Aided Design and Manufacturing System in Mandibular Reconstruction With Fibular-Free Flaps

被引:3
作者
Yodrabum, Nutcha [1 ,6 ]
Rudeejaroonrung, Krit [3 ]
Viriya, Natthaphat [3 ]
Chaikangwan, Irin [1 ]
Kongkunnavat, Natthapong [1 ]
Tianrungroj, Jirapat [2 ]
Ongsiriporn, Mathee [2 ]
Piyaman, Parkpoom [2 ]
Puncreobutr, Chedtha [4 ,5 ]
机构
[1] Mahidol Univ, Fac Med, Dept Surg, Div Plast Surg,Siriraj Hosp, Bangkok, Thailand
[2] Mahidol Univ, Fac Med, Dept Anat, Siriraj Hosp, Bangkok, Thailand
[3] Meticuly Co Ltd, Biomech Res Ctr, Bangkok, Thailand
[4] Chulalongkorn Univ, Fac Engn, Dept Met Engn, Adv Mat Anal Res Unit, Bangkok, Thailand
[5] Chulalongkorn Univ, Biomed Engn Res Ctr, Bangkok, Thailand
[6] Mahidol Univ, Fac Med, Dept Surg, Div Plast & Reconstruct Surg,Siriraj Hosp, 2 WanglangRoad, Bangkok 10700, Thailand
关键词
computer-assisted surgery; mandibular reconstruction; fibular-free flap; ARTICULAR-CARTILAGE THICKNESS; HEAD; ACCURACY; DEFECT;
D O I
10.1097/SCS.0000000000009037
中图分类号
R61 [外科手术学];
学科分类号
摘要
Computer-assisted surgery (CAS) has been introduced to mandible reconstruction with fibular-free flap in cutting guide placement. When CAS cooperates with different plate fixations, the results show various degrees of errors by which this study aimed to evaluate. Mock surgeries were conducted in 3D-printed mandibles with 2 types of defects, limited or extensive, reconstructed from 2 ameloblastoma patients. Three types of fixations, miniplate, manually bending reconstruction plate, and patient-specific plate, are tested, each of which was performed 3 times in each type of defect, adding up to 18 surgeries. One with the least errors was selected and applied to patients whose 3D-printed mandibles were derived. Finally, in vivo errors were compared with the mock. In limited defect, average errors show no statistical significance among all types. In extensive defect, patient-specific plate had a significantly lower average condylar error than manually bending reconstruction plate and miniplate (8.09 +/- 2.52 mm vs. 25.49 +/- 2.72 and 23.13 +/- 13.54 mm, respectively). When patient-specific plate was applied in vivo, the errors were not significantly different from the mock. Patient-specific plates that cooperated with CAS showed the least errors. Nevertheless, manually bent reconstruction plates and miniplates could be applied in limited defects with caution.
引用
收藏
页码:187 / 197
页数:11
相关论文
共 34 条
[1]   Three-dimensional distribution of articular cartilage thickness in the elderly cadaveric acetabulum: a new method using three-dimensional digitizer and CT [J].
Akiyama, K. ;
Sakai, T. ;
Koyanagi, J. ;
Murase, T. ;
Yoshikawa, H. ;
Sugamoto, K. .
OSTEOARTHRITIS AND CARTILAGE, 2010, 18 (06) :795-802
[2]   Miniplates Versus Reconstruction Bars for Oncologic Free Fibula Flap Mandible Reconstruction [J].
Al-Bustani, Saif ;
Austin, Grace Kim ;
Ambrose, Emily Cohn ;
Miller, Justin ;
Hackman, Trevor G. ;
Halvorson, Eric G. .
ANNALS OF PLASTIC SURGERY, 2016, 77 (03) :314-317
[3]   Use of Virtual Surgery and Stereolithography-Guided Osteotomy for Mandibular Reconstruction with the Free Fibula [J].
Antony, Anuja K. ;
Chen, Wei F. ;
Kolokythas, Antonia ;
Weimer, Katherine A. ;
Cohen, Mimis N. .
PLASTIC AND RECONSTRUCTIVE SURGERY, 2011, 128 (05) :1080-1084
[4]   Computer Planning and Intraoperative Navigation for Palatomaxillary and Mandibular Reconstruction With Fibular Free Flaps [J].
Bell, R. Bryan ;
Weimer, Katherine A. ;
Dierks, Eric J. ;
Buehler, Mark ;
Lubek, Joshua E. .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2011, 69 (03) :724-732
[5]   Mandibular reconstruction with vascularised bone flaps: a asystematic review over 25 years. [J].
Brown, J. S. ;
Lowe, D. ;
Kanatas, A. ;
Schache, A. .
BRITISH JOURNAL OF ORAL & MAXILLOFACIAL SURGERY, 2017, 55 (02) :113-126
[6]   CAD/CAM guided secondary mandibular reconstruction of a discontinuity defect after ablative cancer surgery [J].
Ciocca, Leonardo ;
Mazzoni, Simona ;
Fantini, Massimiliano ;
Persiani, Franco ;
Marchetti, Claudio ;
Scotti, Roberto .
JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2012, 40 (08) :E511-E515
[7]   Virtual Bending of Mandibular Reconstruction Plates Using a Computer-Aided Design [J].
Derand, Per ;
Hirsch, Jan-Michael .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2009, 67 (08) :1640-1643
[8]   Accuracy of computer-assisted mandibular reconstructions with free fibula flap: Results of a single-center series [J].
Goormans, Femke ;
Sun, Yi ;
Bila, Michel ;
Schoenaers, Joseph ;
Geusens, Joris ;
Luebbers, Heinz-Theo ;
Coucke, Wim ;
Politis, Constantinus .
ORAL ONCOLOGY, 2019, 97 :69-75
[9]   Mandibular Condyle Reconstruction With Fibula Free-Tissue Transfer: The Role of the Masseter Muscle [J].
Gravvanis, Andreas ;
Anterriotis, Dimitrios ;
Kakagia, Despoina .
JOURNAL OF CRANIOFACIAL SURGERY, 2017, 28 (08) :1955-1959
[10]   Computer-assisted design and rapid prototype modeling in microvascular mandible reconstruction [J].
Hanasono, Matthew M. ;
Skoracki, Roman J. .
LARYNGOSCOPE, 2013, 123 (03) :597-604