A Single-Center Audit of BI-RADS 3 Assessment Category Utilization in Mammography and Breast Ultrasound

被引:0
|
作者
Common, Jessica [1 ]
Abdullah, Peri [2 ]
Alabousi, Abdullah [1 ,3 ,4 ]
机构
[1] McMaster Univ, Fac Hlth Sci, Dept Radiol, Hamilton, ON, Canada
[2] York Univ, Fac Hlth, Dept Kinesiol & Hlth Sci, Toronto, ON, Canada
[3] St Josephs Healthcare Hamilton, Dept Radiol, Hamilton, ON, Canada
[4] St Josephs Healthcare Hamilton, FRCPC, Dept Radiol, 50 Charlton Ave E, Hamilton, ON L8N 4A6, Canada
来源
CANADIAN ASSOCIATION OF RADIOLOGISTS JOURNAL-JOURNAL DE L ASSOCIATION CANADIENNE DES RADIOLOGISTES | 2023年 / 74卷 / 01期
关键词
BI-RADS; 3; probably benign; mammography; breast ultrasound; cancer yield; PROBABLY BENIGN LESIONS; FOLLOW-UP; PATIENT COMPLIANCE; SURVEILLANCE;
D O I
10.1177/08465371221121706
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To evaluate outcomes of breast lesions assessed at our institution as probably benign (Breast Imaging Reporting and Data System [BI-RADS] category 3) with an expected malignancy rate of less than or equal to 2 %. Methods: Average-risk women with a BI-RADS 3 assessment following mammographic and/or ultrasound evaluation at our institution between January 1 and December 31, 2017 were included. Cancer yield was calculated within 90 days and at 6-month intervals up to 36 months. Results: Among 517 women (median age, 52 years; range, 13-89 years) with a BI-RADS 3 assessment, 349 (67.5 %) underwent biopsy or completed follow-up imaging up to 36 months. One hundred and 68 (32.5 %) were lost to follow-up. Thirty of 349 (8.6 %) had their imaging upgraded and underwent biopsy, yielding six cancers (cancer yield, 6 of 349 women [1.7 %]). Among 569 lesions assessed as BI-RADS 3, 92 (16.2 %) were characterized by morphologic features other than those validated as probably benign in prospective clinical studies. Fifty three of 517 women (10.3 %) had follow-up beyond 24 months, and 24 (4.6 %) had follow-up beyond 36 months. Conclusion: Overall utilization of the BI-RADS 3 assessment category at our institution is appropriate with a 1.7 % cancer yield. However, the rate of loss to follow-up, percentage of non-validated findings assessed as probably benign, and redundancy in follow-up protocols are too high, and warrant intervention. A patient handout explaining the BI-RADS 3 assessment category and automatic scheduling of follow-up studies have been implemented at our center to address loss to follow-up.
引用
收藏
页码:69 / 77
页数:9
相关论文
共 50 条
  • [31] Use of the probably benign (BI-RADS category 3) assessment for masses on breast MRI: Is it transferable to general clinical practice?
    Price, Elissa R.
    Sickles, Edward A.
    Yitta, Silaja
    Brasic, Natasha
    Yeh, Melinda J.
    Allen, Isabel E.
    Joe, Bonnie N.
    BREAST JOURNAL, 2018, 24 (02) : 109 - 114
  • [32] Accuracy of mammography and ultrasonography and their BI-RADS in detection of breast malignancy
    Ghaemian, Naser
    Tehrani, Neda Haji Ghazi
    Nabahati, Mehrdad
    CASPIAN JOURNAL OF INTERNAL MEDICINE, 2021, 12 (04) : 573 - 579
  • [33] INTENSITY-INVARIANT TEXTURE ANALYSIS FOR CLASSIFICATION OF BI-RADS CATEGORY 3 BREAST MASSES
    Lo, Chung-Ming
    Moon, Woo Kyung
    Huang, Chiun-Sheng
    Chen, Jeon-Hor
    Yang, Min-Chun
    Chang, Ruey-Feng
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2015, 41 (07) : 2039 - 2048
  • [34] BI-RADS category 3, 4, and 5 lesions identified at preoperative breast MRI in patients with breast cancer: implications for management
    Lee, Si Eun
    Lee, Ji Hye
    Han, Kyunghwa
    Kim, Eun-Kyung
    Kim, Min Jung
    Moon, Hee Jung
    Yoon, Jung Hyun
    Park, Vivian Youngjean
    EUROPEAN RADIOLOGY, 2020, 30 (05) : 2773 - 2781
  • [35] Breast ultrasonography in young Asian women: analyses of BI-RADS final assessment category according to symptoms
    Sohn, Yu-Mee
    Kim, Min Jung
    Kwak, Jin Young
    Moon, Hee Jung
    Kim, Soo Jin
    Kim, Eun-Kyung
    ACTA RADIOLOGICA, 2011, 52 (01) : 35 - 40
  • [36] Comparison of 99mTc-MIBI scintigraphy, ultrasound, and mammography for the diagnosis of BI-RADS 4 category lesions
    Liu, Hongbiao
    Than, Hongwei
    Sun, Da
    BMC CANCER, 2020, 20 (01)
  • [37] Interobserver variability of ultrasound elastography and the ultrasound BI-RADS lexicon of breast lesions
    Park, Chang Suk
    Kim, Sung Hun
    Jung, Na Young
    Choi, Jae Jung
    Kang, Bong Joo
    Jung, Hyun Seouk
    BREAST CANCER, 2015, 22 (02) : 153 - 160
  • [38] Cancer Yield and Patterns of Follow-up for BI-RADS Category 3 after Screening Mammography Recall in the National Mammography Database
    Berg, Wendie A.
    Berg, Jeremy M.
    Sickles, Edward A.
    Burnside, Elizabeth S.
    Zuley, Margarita L.
    Rosenberg, Robert D.
    Lee, Cindy S.
    RADIOLOGY, 2020, 296 (01) : 32 - 41
  • [39] A Nomogram to Predict for Malignant Diagnosis of BI-RADS Category 4 Breast Lesions
    Mazouni, Chafika
    Sneige, Nour
    Rouzier, Roman
    Balleyguier, Corinne
    Bevers, Therese
    Andre, Fabrice
    Vielh, Philippe
    Delaloge, Suzette
    JOURNAL OF SURGICAL ONCOLOGY, 2010, 102 (03) : 220 - 224
  • [40] Comparison of 99mTc-MIBI scintigraphy, ultrasound, and mammography for the diagnosis of BI-RADS 4 category lesions
    Hongbiao Liu
    Hongwei Zhan
    Da Sun
    BMC Cancer, 20