Comparison of serum tumor markers combined with dual-source CT in the diagnosis of lung cancer

被引:8
|
作者
Shan, Yuqing [1 ]
Yin, Xiangyuan [1 ]
Zhao, Na [1 ]
Wang, Jie [2 ]
Yang, Shouxiang [1 ]
机构
[1] Peoples Hosp Rizhao, Dept Imaging, Taian Rd 126, Rizhao 276800, Peoples R China
[2] Lanshan Peoples Hosp Rizhao, Dept Imaging, Rizhao, Peoples R China
关键词
Lung neoplasms; Biomarkers; tumor; Serology; Tomography; X-ray computed; CARCINOEMBRYONIC ANTIGEN CEA; INTERNATIONAL ASSOCIATION; BIOMARKER; CLASSIFICATION; EPIDEMIOLOGY; CYFRA21-1; PROPOSAL;
D O I
10.23736/S0026-4806.21.07124-X
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND: The purpose of this study is to explore the clinical value of serum tumor markers combined with dualsource CT scanning in the diagnosis of lung cancer. METHODS: One hundred-two patients with lung cancer (malignant tumor group), 50 patients with benign lesions (benign control group) and 50 healthy patients (normal control group) were selected as the research objects. The levels of serum carcinoembryonic antigen (CEA), cytokeratin 19 fragment antigen 21-1 (CYFRA21-1) and gastrin releasing peptide precursor 31-98 (Pro-GRP31-98) were detected using the electrochemiluminescence and enzyme-linked immunoassay in three groups of people. Simultaneously, Siemens' second-generation dual-source CT (Siemens AG, Munich, Germany) is used to scan the lungs of patients with lung cancer and benign lesions. Retrospective statistical analysis is utilized to explore the clinical value of serum tumor markers combined with dual-source CT examination in the diagnosis of lung cancer. RESULTS: The levels of serum CEA, CYFRA21-1 and Pro-GRP31-98 in lung cancer patients were significantly higher than those in the benign control group and normal control group, and the difference was statistically significant (P<0.01). There was no statistical difference between the benign control group and the normal control group (P>0.05). The levels of serum CEA, CYFRA21-1, Pro-GRP31-98 had no significant correlation with the age, sex, and tumor site of lung cancer patients (P>0.05). However, the levels of serum CEA, CYFRA21-1, Pro-GRP31-98 have an obvious correlation with tumor size, clinical stage, histological type, combined pleural effusion, recurrence and metastasis after treatment (P<0.05). CT scans of 102 lung cancer patients showed 35 cases of central type, 67 cases of peripheral type, 71 cases with tumor diameter >5cm, 31 cases of <= 5cm and 67 cases of lymph node metastasis. The sensitivities of CEA, CYFRA21-1, Pro-GRP31-98, and dual-source CT in the diagnosis of lung cancer were 64.70%, 60.11%, 56.86% and 77.45%, and the accuracy was 75.00%, 72.37%, 69.74% and 82.89%, respectively. Compared with a single examination, the sensitivity and accuracy of combined examination for the diagnosis of lung cancer were significantly improved, which were 95.10% and 92.76%, respectively. CONCLUSIONS: Joint examinations can effectively improve the rate of lung cancer diagnosis.
引用
收藏
页码:795 / 801
页数:7
相关论文
共 50 条
  • [41] The relationship between tumor markers and pulmonary embolism in lung cancer
    Xiong, Wei
    Zhao, Yunfeng
    Xu, Mei
    Guo, Jian
    Pudasaini, Bigyan
    Wu, Xueling
    Liu, Jinming
    ONCOTARGET, 2017, 8 (25) : 41412 - 41421
  • [42] Quantitative evaluation of pancreatic neuroendocrine tumors utilizing dual-source CT perfusion imaging
    Liu, Ge
    Gao, Yan-Jun
    Li, Xiao-Bing
    Huan, Yi
    Chen, Jian
    Deng, Yan-Meng
    BMC MEDICAL IMAGING, 2024, 24 (01):
  • [43] Effects of Docetaxel Combined with Icotinib on Serum Tumor Markers and Quality of Life of Patients with Advanced Non-Small Cell Lung Cancer
    Lin, Huawei
    Chang, Jing
    Li, Jun
    IRANIAN JOURNAL OF PUBLIC HEALTH, 2020, 49 (10) : 1885 - 1893
  • [44] Dual-Energy CT with Single- and Dual-Source Scanners: Current Applications in Evaluating the Genitourinary Tract
    Kaza, Ravi K.
    Platt, Joel F.
    Cohan, Richard H.
    Caoili, Elaine M.
    Al-Hawary, Mahmoud M.
    Wasnik, Ashish
    RADIOGRAPHICS, 2012, 32 (02) : 353 - 369
  • [45] Dual-source dual-energy CT: dose reduction after endovascular abdominal aortic aneurysm repair
    Buffa, Vitaliano
    Solazzo, Antonio
    D'Auria, Valeria
    Del Prete, Alessandra
    Vallone, Andrea
    Luzietti, Monica
    Madau, Manuela
    Grassi, Roberto
    Miele, Vittorio
    RADIOLOGIA MEDICA, 2014, 119 (12): : 934 - 941
  • [46] Prospective prediction of the major component of urinary stone composition with dual-source dual-energy CT in vivo
    Zhang, G. -M. -Y.
    Sun, H.
    Xue, H. -D.
    Xiao, H.
    Zhang, X. -B.
    Jin, Z. -Y.
    CLINICAL RADIOLOGY, 2016, 71 (11) : 1178 - 1183
  • [47] Alternative tumor markers in the diagnosis of ovarian cancer
    Karakaya, Burcu Kisa
    Baser, Eralp
    Bildaci, Berk
    Comert, Esra Cabuk
    Bayraktar, Nilufer
    Dursun, Polat
    Kuscu, Esra
    Ayhan, Ali
    GINEKOLOGIA POLSKA, 2016, 87 (08) : 565 - 569
  • [48] Diagnostic accuracy and its affecting factors of dual-source CT for assessment of coronary stents patency and in-stent restenosis
    Zhang Xing-hua
    Yang Li
    Wu Jian
    Ju Hai-yue
    Zhang Fan
    He Bin
    Chen Yun-dai
    CHINESE MEDICAL JOURNAL, 2012, 125 (11) : 1936 - 1940
  • [49] Analysis of tumor markers in pleural effusion and serum to verify the correlations between serum tumor markers and tumor size, TNM stage of lung adenocarcinoma
    Chen, Zhongqing
    Wang, Ying
    Fang, Min
    CANCER MEDICINE, 2020, 9 (04): : 1392 - 1399
  • [50] In Vivo Comparison of Radiation Exposure in Third-Generation vs Second-Generation Dual-Source Dual-Energy CT for Imaging Urinary Calculi
    Lam, Jonathan P.
    Alexander, Lauren F.
    William, Haley E.
    Hodge, David O.
    Kofler, James M.
    Morin, Richard L.
    Thiel, David D.
    Cernigliaro, Joseph G.
    JOURNAL OF ENDOUROLOGY, 2021, 35 (11) : 1581 - 1585