Determination of optimal component positioning in THA using 3D preoperative planning

被引:4
|
作者
LaCour, Michael [1 ,2 ]
Ta, Manh [1 ]
Nachtrab, Jarrod [1 ]
Nguyen, Thang [1 ]
Komistek, Richard [1 ]
机构
[1] Univ Tennessee, Mech Aerosp & Biomed Engn, Knoxville, TN 37916 USA
[2] Univ Tennessee, 310 Perkins Hall,1506 Middle Dr, Knoxville, TN 37916 USA
关键词
arthroplasty-hip; biomechanics; gait; kinematics and kinetics; TOTAL HIP-ARTHROPLASTY; REPLACEMENT; IMPLANTATION; PLACEMENT; ACCURACY; PATIENT; EDGE;
D O I
10.1002/jor.25803
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Advancements in three-dimensional (3D) preoperative planning tools can offer surgeons and design engineers detailed feedback and additional opportunities for clinical advancements. The objective of this study is to use a 3D total hip arthroplasty preoperative planning tool to compare femoral component alignment for three different stem systems. The planning tool in this study used morphology data of femoral bones gathered from a CT database, seven from postoperative patients and 63 from statistical shape models (SSMs), to suggest specific implant sizes and optimal placements in 3D to match each specific bone model. Retrospective validations of predicted stem size and femoral version were first performed by comparing planner-chosen and surgeon-implanted stem sizes and version angles for the seven postoperative patients. Next, the alignment of three different stem systems was evaluated using bone models generated from SSMs, with a quantitative focus on component head positioning. In the validation study, the planner accurately selected stem size and orientation compared to the surgeon for all assessed subjects. In the stem evaluation, the three stem systems yielded different accuracies in component placement, with the newest stem system demonstrating the closest restoration of anatomical head center location. It is evident that new stem designs may have the potential for increased accuracy over their predecessors, demonstrating that new stem designs can offer improved intraoperative and postoperative alignment potential. The 3D preoperative planning tools can provide novel and reliable data to both surgeons and design engineers, which can ultimately improve clinical outcomes and future implant designs.
引用
收藏
页码:1557 / 1565
页数:9
相关论文
共 50 条
  • [31] Optimal Camera Placement for 3D Environment
    Yusoff, Siti Kamaliah Mohd
    Said, Abas Md
    Ismail, Idris
    SOFTWARE ENGINEERING AND COMPUTER SYSTEMS, PT 2, 2011, 180 : 448 - +
  • [32] Stereo Vision-Based 3D Positioning and Tracking
    Islam, Atiqul
    Asikuzzaman, Md
    Khyam, Mohammad Omar
    Noor-A-Rahim, Md
    Pickering, Mark R.
    IEEE ACCESS, 2020, 8 : 138771 - 138787
  • [33] Can 3D surgical planning and patient specific instrumentation reduce hip implant inventory? A prospective study
    Di Laura, Anna
    Henckel, Johann
    Hothi, Harry
    Hart, Alister
    3D PRINTING IN MEDICINE, 2020, 6 (01)
  • [34] Intraoperative Assessment of the Axial Rotational Positioning of a Modern Ankle Arthroplasty Tibial Component Using Preoperative Patient-Specific Instrumentation Guidance
    Gagne, Oliver J.
    Veljkovic, Andrea
    Townshend, Dave
    Younger, Alastair
    Wing, Kevin J.
    Penner, Murray J.
    FOOT & ANKLE INTERNATIONAL, 2019, 40 (10) : 1160 - 1165
  • [35] 3X-Knee: A Novel Technology for 3D Preoperative Planning and Postoperative Evaluation of TKA Based on 2D X-Rays
    Zheng, Guoyan
    Alcoltekin, Alper
    Thelen, Benedikt
    Nolte, Lutz-P
    INTELLIGENT ORTHOPAEDICS: ARTIFICIAL INTELLIGENCE AND SMART IMAGE-GUIDED TECHNOLOGY FOR ORTHOPAEDICS, 2018, 1093 : 93 - 103
  • [36] \ Virtual 3D Prosthetic and Implant Planning Using Cone Beam Imaging and CEREC
    Ritter, L.
    Neugebauer, J.
    Rothamel, D.
    Karapetian, V.
    Mischkowski, R.
    Zoeller, J. E.
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING, VOL 25, PT 11: BIOMEDICAL ENGINEERING FOR AUDIOLOGY, OPHTHALMOLOGY, EMERGENCY AND DENTAL MEDICINE, 2009, 25 (11): : 235 - +
  • [37] 3D surgical planning of pediatric tumors: a review
    Pereira, Helena Rico
    Barzegar, Mojtaba
    Hamadelseed, Osama
    Esteve, Arnau Valls
    Munuera, Josep
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2022, 17 (04) : 805 - 816
  • [38] 3D Computer aided treatment planning in endodontics
    van der Meer, Wicher J.
    Vissink, Arjan
    Ng, Yuan Ling
    Gulabivala, Kishor
    JOURNAL OF DENTISTRY, 2016, 45 : 67 - 72
  • [39] 3D walking biped: optimal swing of the arms
    Aoustin, Y.
    Formalskii, A. M.
    MULTIBODY SYSTEM DYNAMICS, 2014, 32 (01) : 55 - 66
  • [40] Preoperative implant selection for unilateral breast reconstruction using 3D imaging with the Microsoft Kinect sensor
    Pohlmann, Stefanie T. L.
    Harkness, Elaine
    Taylor, Christopher J.
    Gandhi, Ashu
    Astley, Susan M.
    JOURNAL OF PLASTIC RECONSTRUCTIVE AND AESTHETIC SURGERY, 2017, 70 (08) : 1059 - 1067