Determination of optimal component positioning in THA using 3D preoperative planning

被引:4
|
作者
LaCour, Michael [1 ,2 ]
Ta, Manh [1 ]
Nachtrab, Jarrod [1 ]
Nguyen, Thang [1 ]
Komistek, Richard [1 ]
机构
[1] Univ Tennessee, Mech Aerosp & Biomed Engn, Knoxville, TN 37916 USA
[2] Univ Tennessee, 310 Perkins Hall,1506 Middle Dr, Knoxville, TN 37916 USA
关键词
arthroplasty-hip; biomechanics; gait; kinematics and kinetics; TOTAL HIP-ARTHROPLASTY; REPLACEMENT; IMPLANTATION; PLACEMENT; ACCURACY; PATIENT; EDGE;
D O I
10.1002/jor.25803
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Advancements in three-dimensional (3D) preoperative planning tools can offer surgeons and design engineers detailed feedback and additional opportunities for clinical advancements. The objective of this study is to use a 3D total hip arthroplasty preoperative planning tool to compare femoral component alignment for three different stem systems. The planning tool in this study used morphology data of femoral bones gathered from a CT database, seven from postoperative patients and 63 from statistical shape models (SSMs), to suggest specific implant sizes and optimal placements in 3D to match each specific bone model. Retrospective validations of predicted stem size and femoral version were first performed by comparing planner-chosen and surgeon-implanted stem sizes and version angles for the seven postoperative patients. Next, the alignment of three different stem systems was evaluated using bone models generated from SSMs, with a quantitative focus on component head positioning. In the validation study, the planner accurately selected stem size and orientation compared to the surgeon for all assessed subjects. In the stem evaluation, the three stem systems yielded different accuracies in component placement, with the newest stem system demonstrating the closest restoration of anatomical head center location. It is evident that new stem designs may have the potential for increased accuracy over their predecessors, demonstrating that new stem designs can offer improved intraoperative and postoperative alignment potential. The 3D preoperative planning tools can provide novel and reliable data to both surgeons and design engineers, which can ultimately improve clinical outcomes and future implant designs.
引用
收藏
页码:1557 / 1565
页数:9
相关论文
共 50 条
  • [1] Preoperative planning for accurate glenoid component positioning in reverse shoulder arthroplasty
    Berhouet, J.
    Gulotta, L. V.
    Dines, D. M.
    Craig, E.
    Warren, R. F.
    Choi, D.
    Chen, X.
    Kontaxis, A.
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2017, 103 (03) : 407 - 413
  • [2] 3D preoperative predictions of in vivo hip stability and edge loading for neutral and lipped liners
    LaCour, Michael
    Nachtrab, Jarrod
    Nguyen, Thang
    Dessinger, Garett M.
    Jacobs, Andrew
    Komistek, Richard
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2024, 42 (09) : 2026 - 2034
  • [3] Validation of a statistical shape model-based 2D/3D reconstruction method for determination of cup orientation after THA
    Zheng, G.
    von Recum, J.
    Nolte, L. -P.
    Gruetzner, P. A.
    Steppacher, S. D.
    Franke, J.
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2012, 7 (02) : 225 - 231
  • [4] 3D Printing in Medicine for Preoperative Surgical Planning: A Review
    Tejo-Otero, A.
    Buj-Corral, I.
    Fenollosa-Artes, F.
    ANNALS OF BIOMEDICAL ENGINEERING, 2020, 48 (02) : 536 - 555
  • [5] 3D surgical printing for preoperative planning of trabecular augments in acetabular fracture sequel
    Sanchez-Perez, Coral
    Rodriguez-Lozano, Guillermo
    Rojo-Manaute, Jose
    Vaquero-Martin, Javier
    Chana-Rodriguez, Francisco
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2018, 49 : S36 - S43
  • [6] Accurate determination of post-operative 3D component positioning in total knee arthroplasty: the AURORA protocol
    Wakelin, Edgar A.
    Tran, Linda
    Twiggs, Joshua G.
    Theodore, Willy
    Roe, Justin P.
    Solomon, Michael I.
    Fritsch, Brett A.
    Miles, Brad P.
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2018, 13
  • [7] Reliably calibrating X-ray images required for preoperative planning of THA using a device-adapted magnification factor
    Brueggemann, Heinrich
    Paulsen, Aksel
    Oppedal, Ketil
    Grasmair, Markus
    Hoemberg, Dietmar
    PLOS ONE, 2024, 19 (08):
  • [8] Innovations in Preoperative Planning: Insights into Another Dimension Using 3D Printing for Cardiac Disease
    Farooqi, Kanwal M.
    Mahmood, Feroze
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2018, 32 (04) : 1937 - 1945
  • [9] Application and evaluation of artificial intelligence 3D preoperative planning software in developmental dysplasia of the hip
    Hongbin Xie
    Jiafeng Yi
    Yijian Huang
    Renwen Guo
    Yubo Liu
    Xiangpeng Kong
    Wei Chai
    Journal of Orthopaedic Surgery and Research, 19
  • [10] Application and evaluation of artificial intelligence 3D preoperative planning software in developmental dysplasia of the hip
    Xie, Hongbin
    Yi, Jiafeng
    Huang, Yijian
    Guo, Renwen
    Liu, Yubo
    Kong, Xiangpeng
    Chai, Wei
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2024, 19 (01)